Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study

被引:8
|
作者
Veger, Hugo T. C. [1 ]
Pasveer, Erik H. [1 ]
Westenberg, Jos J. M. [2 ]
Wever, Jan J. [1 ]
van Eps, Randolph G. Statius [1 ]
机构
[1] Haga Teaching Hosp, Dept Vasc Surg, Els Borst Eilerspl 275, NL-2545 AA The Hague, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
关键词
aortic dissection; type B; four-dimensional flow magnetic resonance imaging; ex-vivo; THORACIC AORTA; TEAR SIZE; MANAGEMENT; QUANTIFICATION; PRESSURE; PORCINE; MOTION; MODEL;
D O I
10.1177/15385744211017117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. Results: During both experiments an increase in FLV (initial experiment: Delta FLV = 2.05 ml, p < 0.001, repeated experiment: Delta FLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: Delta WSS = 1.2 Pa, p = 0.004, repeated experiment: Delta WSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV (p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 30 条
  • [1] ASSESSMENT OF BLOOD FLOW PATTERNS IN PATIENTS WITH TYPE B AORTIC DISSECTION BY 4-DIMENSIONAL FLOW PHASE CONTRAST MAGNETIC RESONANCE IMAGING - A PILOT STUDY
    Khan, N.
    Hall-Barrientos, P.
    Radjenovic, A.
    Douglas, P.
    Roditi, G.
    HEART, 2020, 106 : A10 - A10
  • [2] Tear size and location impacts false lumen pressure in an ex-vivo model of chronic type B aortic dissection
    Tsai, Thomas T.
    Schlicht, Marty
    Khanaler, Khalil
    Berguer, Ramon
    Bull, Joseph L.
    Montgomery, Daniel G.
    Valassis, Doug
    Williams, David M.
    Eagle, Kim A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 383A - 383A
  • [3] False Lumen Flow Assessment by Magnetic Resonance Imaging and Long-Term Outcomes in Uncomplicated Aortic Dissection
    Evangelista, Arturo
    Pineda, Victor
    Guala, Andrea
    Bijnens, Bart
    Cuellar, Hug
    Rudenick, Paula
    Sao-Aviles, Augusto
    Ruiz, Aroa
    Teixido-Tura, Gisela
    Rodriguez-Lecoq, Rafael
    Bellmunt, Sergi
    Ferreira, Ignacio
    Rodriguez-Palomares, Jose
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (24) : 2415 - 2427
  • [4] Aortic Valve Stenosis Alters Expression of Regional Aortic Wall Shear Stress: New Insights From a 4-Dimensional Flow Magnetic Resonance Imaging Study of 571 Subjects
    van Ooij, Pim
    Markl, Michael
    Collins, Jeremy D.
    Carr, James C.
    Rigsby, Cynthia
    Bonow, Robert O.
    Malaisrie, S. Chris
    McCarthy, Patrick M.
    Fedak, Paul W. M.
    Barker, Alex J.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (09):
  • [5] The use of 4-dimensional flow magnetic resonance imaging and fluid structure interaction analysis to predict failure of medical therapy in acute uncomplicated type B aortic dissection
    Cebull, Hannah L.
    Liu, Minliang
    Piccinelli, Marina
    Dong, Hai
    Naeem, Muhammad
    Du, Yuhang
    Oshinski, John N.
    Gleason, Rudolph L.
    Elefteriades, John A.
    Leshnower, Bradley G.
    JTCVS TECHNIQUES, 2024, 27 : 40 - 44
  • [6] False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth
    David Marlevi
    Julio A. Sotelo
    Ross Grogan-Kaylor
    Yunus Ahmed
    Sergio Uribe
    Himanshu J. Patel
    Elazer R. Edelman
    David A. Nordsletten
    Nicholas S. Burris
    Journal of Cardiovascular Magnetic Resonance, 23
  • [7] False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth
    Marlevi, David
    Sotelo, Julio A.
    Grogan-Kaylor, Ross
    Ahmed, Yunus
    Uribe, Sergio
    Patel, Himanshu J.
    Edelman, Elazer R.
    Nordsletten, David A.
    Burris, Nicholas S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [8] Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress analysis
    Frydrychowicz, Alex
    Berger, Alexander
    Russe, Maximilan F.
    Stalder, Aurelien F.
    Harloff, Andreas
    Dittrich, Sven
    Hennig, Juergen
    Langer, Mathias
    Markl, Michael
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (02): : 400 - 407
  • [9] Four-dimensional flow cardiovascular magnetic resonance in aortic dissection: Assessment in an ex vivo model and preliminary clinical experience
    de Beaufort, Hector W.
    Shah, Dipan J.
    Patel, Avni P.
    Jackson, Matthew S.
    Spinelli, Domenico
    Yang, Eric Y.
    Ghosn, Mohamad G.
    Autry, Kyle
    Igo, Stephen R.
    Lumsden, Alan B.
    Little, Stephen H.
    Trimarchi, Santi
    Bismuth, Jean
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (02): : 467 - +
  • [10] Machine learning for the automatic assessment of aortic rotational flow and wall shear stress from 4D flow cardiac magnetic resonance imaging
    Juan Garrido-Oliver
    Jordina Aviles
    Marcos Mejía Córdova
    Lydia Dux-Santoy
    Aroa Ruiz-Muñoz
    Gisela Teixido-Tura
    Gonzalo D. Maso Talou
    Xabier Morales Ferez
    Guillermo Jiménez
    Arturo Evangelista
    Ignacio Ferreira-González
    Jose Rodriguez-Palomares
    Oscar Camara
    Andrea Guala
    European Radiology, 2022, 32 : 7117 - 7127