Simulation and Economic Research of Circulating Cooling Water Waste Heat and Water Resource Recovery System

被引:8
|
作者
Yang, Li [1 ,2 ]
Ren, Yunfeng [3 ]
Wang, Zhihua [4 ]
Hang, Zhouming [5 ]
Luo, Yunxia [1 ,2 ]
机构
[1] Zhejiang Univ Water Resources & Elect Power, Key Lab Technol Rural Water Management Zhejiang P, Hangzhou 310018, Peoples R China
[2] Zhejiang Univ Water Resources & Elect Power, Coll Elect Engn, Hangzhou 310018, Peoples R China
[3] Zhejiang Pyneo Technol Ltd Co, Hangzhou 311121, Peoples R China
[4] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou 310012, Peoples R China
[5] Zhejiang Univ Water Resources & Elect Power, Coll Mech & Automot Engn, Hangzhou 310018, Peoples R China
关键词
heat pump; Aspen Plus; waste heat; COP; economic analysis; PERFORMANCE; PUMP; ENTROPY;
D O I
10.3390/en14092496
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Industrial circulating cooling water contains a large amount of low-quality energy, which is lost to the environment through cooling towers. It is of great significance and potential to recover the waste heat to improve energy-saving effects and economic efficiency. However, the effect of common water harvesting and energy saving devices is not significant. Heat pumps have been shown to be effective in improving low-quality heat energy in energy conversion systems, although there are not many applications of heat pump scenarios in engineering practice. Based on this, a recovery solution of circulating cooling water waste heat and water resource using lithium bromide absorption heat pump has been put forward. The energy-saving performance of the recovery system was simulated and analyzed using Aspen Plus V10.0 (Bedford, MA, USA) to explore the effects of the parameters of the working medium in evaporators, condensers, absorbers, generators, heat exchangers, etc., and the modelling results indicated that the evaporation pressure and temperature have a great influence on the system COP (coefficient of performance) and can raise the thermal economy of the system. The heat from driving steam and heating capacity both increased with the increase in generating temperature, while the increase in temperature difference between evaporation and condensation inhibits the COP of heat pump systems. Furthermore, economic analyses and comparisons of the recovery solutions were conducted and the recovery solution of circulating cooling water waste heat with heat pump had the best economic performance due to the annual income from the recovery of waste heat and water resource. The static payback period results indicate that the recovery solution from circulating cooling water waste heat with a heat pump has better economic performance than the scenario with a cooling tower. The waste heat recovery solution with a heat pump can improve the thermal economy of the system and has a great guiding significance for engineering practice.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Research progress of removing calcium carbonate fouling in circulating cooling water system
    Zhao, Yan
    Zhang, Lixin
    Gao, Ming
    Liu, Jingnan
    Zhao, Shengxian
    Jingxi Huagong/Fine Chemicals, 2020, 37 (12): : 2447 - 2456
  • [32] Heat pump CPCS-RBF predictive control based on multiple boundary conditions in circulating water waste heat recovery system
    Zhou, Hongyu
    Du, Xuesen
    Zhang, Zhenhua
    Huang, Yaozhen
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (03): : 645 - 651
  • [33] Flexibility of Waste Resource Recovery Facilities for water Reuse
    Aichouche, Farouk
    Benyahia, Boumediene
    Heran, Marc
    Harmand, Jerome
    2020 EUROPEAN CONTROL CONFERENCE (ECC 2020), 2020, : 570 - 574
  • [34] RESOURCE-RECOVERY WASTE-WATER TREATMENT
    JEWELL, WJ
    AMERICAN SCIENTIST, 1994, 82 (04) : 366 - 375
  • [35] Influences of water quality on biofouling forming in circulating cooling water system
    Liu, Fang
    Hou, Yan-Mei
    Zhao, Chao-Cheng
    Zhang, Gui-Zhi
    Yang, Xiao-Jie
    Zhongguo Shiyou Daxue Xuebao (Ziran Kexue Ban)/Journal of China University of Petroleum (Edition of Natural Science), 2009, 33 (02): : 149 - 154
  • [36] The Research of Automatic Monitoring Devices for Circulating Cooling Water
    Sun, Mojie
    Liu, Song
    Wei, Xingshuang
    SUSTAINABLE DEVELOPMENT OF NATURAL RESOURCES, PTS 1-3, 2013, 616-618 : 1940 - 1943
  • [37] MANAGING WASTE HEAT WITH THE WATER COOLING-TOWER
    DICKEY, JB
    COMBUSTION, 1979, 50 (11): : 12 - 19
  • [38] Generalised water resource system simulation
    1600, IE Aust, Barton, Aust
  • [39] Modelling and Simulation of Concentrating Photovoltaic System with Earth Water Heat Exchanger Cooling
    Centre for Renewable Energy and Environment Development , Department of Mechanical Engineering, Birla Institute of Technology and Science, Pilani, Rajasthan
    333031, India
    不详
    110003, India
    Energy Procedia, 1876, (78-85):
  • [40] Rational Loading on Combined Waste Heat Recovery Cooling System
    Radchenko, Andrii
    Forduy, Serhiy
    Kantor, Serhiy
    Zelikov, Oleksii
    Khaldobin, Viktor
    ADVANCED MANUFACTURING PROCESSES III, INTERPARTNER-2021, 2022, : 634 - 643