Polyaniline Langmuir-Blodgett film modified glassy carbon electrode as a voltammetric sensor for determination of Ag+ ions

被引:33
|
作者
Liu, Qiongyan [1 ]
Wang, Fei [1 ,2 ]
Qiao, Yonghui [1 ]
Zhang, Shusheng [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450001, Peoples R China
[2] Henan Inst Engn, Dept Mat & Chem Engn, Zhengzhou 450007, Peoples R China
基金
中国国家自然科学基金;
关键词
Langmuir-Blodgett film; Polyaniline; p-Toluenesulfonic acid; Voltammetric sensor; Silver (I) ion; ORGANIC POLYMERS; BIOSENSOR; CONDUCTIVITY; NANOFIBERS; HYDROGEN;
D O I
10.1016/j.electacta.2009.10.069
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly sensitive electrochemical sensor made of a glassy carbon electrode (GCE) coated with a Langmuir-Blodgett film (LB) containing polyaniline (PAn) doped with p-toluenesulfonic acid (PTSA) (LB/PAn-PTSA/GCE) has been used for the detection of trace concentrations of Ag+. UV-vis absorption spectra indicated that the PAn was doped by PTSA. The surface morphology of the PAn LB film was characterized by atomic force microscopy (AFM). The electrochemical properties of this LB/PAn-PTSA/GCE were studied using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. The LB/PAn-PTSA/GCE was used as a voltammetric sensor for determination of trace Ag+ at pH 5.0 using linear scanning stripping voltammetry. Under the optimal experimental conditions, the stripping current was proportional to the Ag+ concentration over the range from 6.0 x 10(-10) mol L-1 to 1.0 x 10(-6) mol L-1, with a detection limit of 4.0 x 10(-1)0 mol L-1. The high sensitivity, selectivity, and stability of this LB/PAn-FTSA/GCE also demonstrated its practical utility for simple, rapid and economical determination of Ag+ in water samples. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1795 / 1800
页数:6
相关论文
共 50 条
  • [31] Immobilization of DNA on a glassy carbon electrode based on Langmuir-Blodgett technique: application to the detection of epinephrine
    Wang, Fei
    Xu, Ying
    Wang, Le
    Lu, Kui
    Ye, Baoxian
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (06) : 2127 - 2133
  • [32] A novel poly(cyanocobalamin) modified glassy carbon electrode as electrochemical sensor for voltammetric determination of peroxynitrite
    Wang, Yan
    Chen, Zhen-zhen
    TALANTA, 2010, 82 (02) : 534 - 539
  • [33] Sensor application of pyridine modified calix[4]arene Langmuir-Blodgett thin film
    Erdogan, Cansu Ozkaya
    Capan, Rifat
    Acikbas, Yaser
    Ozmen, Mustafa
    Bayrakci, Mevlut
    OPTIK, 2022, 265
  • [34] Sensor application of pyridine modified calix[4]arene Langmuir-Blodgett thin film
    Ozkaya Erdogan, Cansu
    Capan, Rifat
    Acikbas, Yaser
    Ozmen, Mustafa
    Bayrakci, Mevlut
    Optik, 2022, 265
  • [35] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895
  • [37] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [38] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [39] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [40] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519