Pulse-Echo Ultrasonic Testing of Adhesively Bonded Joints in Glass Facades

被引:10
|
作者
Mojskerc, Bor [1 ]
Kek, Tomaz [1 ]
Grum, Janez [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, Askerceva 6, SI-1000 Ljubljana, Slovenia
关键词
ultrasonic testing; pulse-echo method; adhesively bonded joints; glass facades;
D O I
10.5545/sv-jme.2015.2988
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This article presents a pulse-echo ultrasonic method of evaluation of adhesively bonded joints in glass facades by means of the amplitudes of reflected ultrasonic signals. Glass facade specimens consist of three basic components: hardened glass, polysulfide or silicone adhesive and a polymer profile. Each component has its own specific acoustic impedance, which relates to a difference in the ultrasound reflection and transmission coefficients. Several glass facade specimens containing defects like air pockets, grease and duct tape are analysed. Measurements are carried out using a normal incidence piezoelectric transducer. Experiments are performed on several adhesively bonded joints in order to detect the defects in the glass-adhesive and adhesive-polymer profile interfaces. Most of the defects, except smaller areas of grease, can be successfully detected. The experimental results suggest that pulse-echo ultrasonic testing is a reasonable way of evaluating of adhesively bonded joints in glass facades.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 50 条
  • [41] ECHO test Selection of Ultrasonic Transducer Focal and Water Path Lengths for Immersion Pulse-echo Testing of Cylinders
    Beck, K. H.
    MATERIALS EVALUATION, 2010, 68 (12) : 1329 - 1331
  • [42] Detection of disbonds in multi-layer bonded structures using the laser ultrasonic pulse-echo mode
    Zhang, Kuanshuang
    Li, Shicheng
    Zhou, Zhenggan
    ULTRASONICS, 2019, 94 : 411 - 418
  • [43] Ultrasonic detection of interface crack in adhesively bonded dcb joints
    Chung, N.-Y.
    Park, S.-I.
    Lee, M.-D.
    Park, C.-H.
    International Journal of Automotive Technology, 2002, 3 (04) : 157 - 163
  • [44] Ultrasonic characterization of accelerated environmental degradation of adhesively bonded joints
    Rokhlin, SI
    Baltazar, A
    Xie, B
    Chen, J
    ADHESIVE JOINTS: FORMATION, CHARACTERISTICS AND TESTING, VOL 2, 2002, : 337 - 360
  • [45] ULTRASONIC MONITORING OF FATIGUE DAMAGE DEVELOPMENT IN ADHESIVELY BONDED JOINTS
    KLINE, RA
    FIDAALI, MA
    MATERIALS EVALUATION, 1985, 43 (10) : 1337 - 1337
  • [46] Nondestructive evaluation of adhesively bonded joints using ultrasonic technique
    Yi, W
    Jang, CS
    Han, JY
    Kim, MG
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 1833 - 1838
  • [47] CHIRP SIGNAL MATCHING AND SIGNAL POWER OPTIMIZATION IN PULSE-ECHO MODE ULTRASONIC NONDESTRUCTIVE TESTING
    POLLAKOWSKI, M
    ERMERT, H
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) : 655 - 659
  • [48] High Resolution Ultrasonic Attenuation Measurement in Pulse-echo Setup
    Dubey, P. K.
    Rajagopalan, S.
    Vyaghra, V. R.
    Pendsey, V. M.
    Sharma, S. J.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2008, 23 (04): : 245 - 252
  • [49] Numerical evaluation of ultrasonic pulse-echo subwavelength defect detection
    Yin, XT
    Morris, SA
    O'Brien, WD
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 729 - 732
  • [50] SPECTRAL CORRELATION IN ULTRASONIC PULSE-ECHO SIGNAL-PROCESSING
    DONOHUE, KD
    BRESSLER, JM
    VARGHESE, T
    BILGUTAY, NM
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (04) : 330 - 337