Calibration and optimization of Bragg edge analysis in energy-resolved neutron imaging experiments

被引:5
|
作者
Tremsin, A. S. [1 ]
Bilheux, H. Z. [2 ]
Bilheux, J. C. [2 ]
Shinohara, T. [3 ]
Oikawa, K. [3 ]
Gao, Y. [4 ]
机构
[1] Univ Calif Berkeley, Space Sci Lab, Berkeley, CA 94720 USA
[2] Oak Ridge Natl Lab, Spallat Neutron Source, Oak Ridge, TN 37830 USA
[3] Japan Atom Energy Agcy, Ibaraki 3191195, Japan
[4] Gen Elect Global Res Ctr, Niskayuna, NY 12309 USA
基金
美国能源部;
关键词
Energy-resolved neutron imaging; Bragg edges; Microstructure; Strain; TIME; TRANSMISSION; MONOCHROMATOR; RADIOGRAPHY; DIFFRACTION; BEAM;
D O I
10.1016/j.nima.2021.165493
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The investigation of microstructure of crystalline materials is one of the possible and frequently used applications of energy-resolved neutron imaging. The position of Bragg edges is defined by sharp changes in neutron transmission and can thus be determined by the measurement of the transmission spectra as a function of neutron wavelength. The accuracy of this measurement depends on both the data analysis technique and the quality of the measured spectra. While the optimization of reconstruction methods was addressed in several previous studies, here we introduce an important prerequisite when aiming for high resolution Bragg edge strain imaging - a well calibrated flight path across the entire field of view (FOV). Compared to e.g. powder diffraction, imaging often uses slightly different geometries and hence requires a calibration for each particular setup. We herein show the importance of this calibration across the entire FOV in order to determine the instrumental error correction for pulsed neutron beamlines. In addition, we also consider the precision of Bragg edge reconstruction as a function of integration time and the minimal sample area. We demonstrate that, with a proper calibration procedure, the Bragg edge wavelength distribution across the entire sample can be reconstructed with an accuracy of..../.. = +/- similar to 0.01%. Our experiments indicate that the strain maps of Inconel 625 samples printed by a direct metal laser melting additive manufacturing technique can be reconstructed with the precision of +/- similar to 100..... The full FOV calibration technique becomes even more important with the development of advanced neutron energy-resolved imaging beamlines and detectors with large FOVs.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Energy-resolved neutron SEU measurements from 22 to 160 MeV
    Johansson, K
    Dyreklev, P
    Granbom, B
    Olsson, N
    Blomgren, J
    Renberg, PU
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 2519 - 2526
  • [42] An edge-on energy-resolved X-ray semiconductor detector
    Yan, Tengfei
    Yang, Chunlei
    Cui, Xiaodong
    SOLID STATE COMMUNICATIONS, 2021, 332
  • [43] Energy-resolved coincidence counting using an FPGA for nuclear lifetime experiments
    Vretenar, Mario
    Erceg, Natasa
    Karuza, Marin
    AMERICAN JOURNAL OF PHYSICS, 2019, 87 (12) : 997 - 1003
  • [44] Energy-resolved neutron imaging with glass gas electron multiplier and dynamic time-over-threshold method
    Mitsuya, Yuki
    Shimazoe, Kenji
    Fujiwara, Takeshi
    Takahashi, Hiroyuki
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01):
  • [45] Effect of stress on NiO reduction in solid oxide fuel cells: a new application of energy-resolved neutron imaging
    Makowska, Malgorzata G.
    Strobl, Markus
    Lauridsen, Erik M.
    Frandsen, Henrik L.
    Tremsin, Anton S.
    Kardjilov, Nikolay
    Manke, Ingo
    Kelleher, Joe F.
    Kuhn, Luise Theil
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2015, 48 : 401 - 408
  • [46] Energy-Resolved Neutron Imaging using a Delay Line Current-Biased Kinetic-Inductance Detector
    Shishido, Hiroaki
    Nishimura, Kazuma
    The Dang Vu
    Kojima, Kenji M.
    Koyama, Tomio
    Oikawa, Kenichi
    Harada, Masahide
    Miyajima, Shigeyuki
    Hidaka, Mutsuo
    Oku, Takayuki
    Soyama, Kazuhiko
    Aizawa, Kazuya
    Suzuki, Soh Y.
    Ishida, Takekazu
    32ND INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS2019), 2020, 1590
  • [47] Laboratory implementation of edge illumination X-ray phase-contrast imaging with energy-resolved detectors
    Diemoz, P. C.
    Endrizzi, M.
    Vittoria, F. A.
    Hagen, C. K.
    Kallon, G.
    Basta, D.
    Marenzana, M.
    Delogu, P.
    Vincenzi, A.
    De Ruvo, L.
    Spandre, G.
    Brez, A.
    Bellazzini, R.
    Olivo, A.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [48] Non-destructive mapping of water distribution through white-beam and energy-resolved neutron imaging
    Tremsin, A. S.
    Shinohara, T.
    Oikawa, K.
    Li, Jiaqi
    Monteiro, P. J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 927 : 174 - 183
  • [49] Energy-resolved neutron imaging with high spatial resolution using a superconducting delay-line kinetic inductance detector
    Iizawa, Yuki
    Shishido, Hiroaki
    Nishimura, Kazuma
    The Dang Vu
    Kojima, Kenji M.
    Koyama, Tomio
    Oikawa, Kenichi
    Harada, Masahide
    Miyajima, Shigeyuki
    Hidaka, Mutsuo
    Oku, Takayuki
    Soyama, Kazuhiko
    Aizawa, Kazuya
    Suzuki, Soh Y.
    Ishida, Takekazu
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2019, 32 (12):
  • [50] Imaging electronic motions in atoms by energy-resolved ultrafast electron diffraction
    Shao, Hua-Chieh
    Starace, Anthony F.
    PHYSICAL REVIEW A, 2014, 90 (03):