Acetylcholinesterase Biosensor for the Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode

被引:16
|
作者
Jeyapragasam, Tharini [1 ]
Saraswathi, R. [2 ]
Chen, Shen-Ming [3 ]
Chen, Tse-Wei [3 ]
机构
[1] Rajarajan Inst Sci, Madurai, Tamil Nadu, India
[2] Madurai Kamaraj Univ, Sch Chem, Dept Mat Sci, Madurai, Tamil Nadu, India
[3] Natl Taipei Univ Technolgoy, Dept Chem Engn & Biotechnol, Taipei, Taiwan
来源
关键词
Pesticide biosensor; acetyl cholinesterase; methyl parathion; electrochemically reduced graphene oxide; Nafion; FUNCTIONALIZED GRAPHENE; ORGANOPHOSPHORUS; NANOPARTICLES; PESTICIDES; IMMOBILIZATION; NANOTUBES; CHOLINE;
D O I
10.20964/2017.06.77
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report the fabrication of a methyl parathion (MP) biosensor based on acetyl cholinesterase (AChE) immobilized on reduced graphene oxide (ERGO)-Nafion (Nf) modified glassy carbon electrode. ERGO-Nf acts as a biocompatible immobilization matrix for AChE for the analysis of MP. Electrochemical oxidation of acetylthiocholine chloride occurs at 0.7 V vs. Ag/AgCl in phosphate buffer solution (pH 7). Various experimental parameters such as effect of scan rate, MP concentration, acetylthiocholine chloride concentration, AChE loading and incubation time have been optimized for the sensor calibration. The calibration curve of MP has been constructed using square wave voltammetry in the concentration range of 2 x 10(-9) M to 7 x 10(-7) M and the sensor shows good reproducibility and stability. The sensor is found to have an estimated detection limit of 1 x 10(-9) M. The biosensor has been applied for the determination of methyl parathion in a vegetable sample.
引用
收藏
页码:4768 / 4781
页数:14
相关论文
共 50 条
  • [21] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547
  • [22] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Norazriena Yusoff
    Perumal Rameshkumar
    Muhammad Mehmood Shahid
    Sheng-Tung Huang
    Nay Ming Huang
    Microchimica Acta, 2017, 184 : 3291 - 3299
  • [23] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Shahid, Muhammad Mehmood
    Huang, Sheng-Tung
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2017, 184 (09) : 3291 - 3299
  • [24] A STUDY OF URICASE BIOSENSOR BASED ON A GLASSY-CARBON ELECTRODE MODIFIED WITH NAFION AND METHYL VIOLOGEN
    JIN, LT
    YE, JS
    TONG, W
    FANG, YZ
    MIKROCHIMICA ACTA, 1993, 112 (1-4) : 71 - 75
  • [25] Electrochemiluminescence Biosensor for Glucose Based on Graphene/Nafion/GOD Film Modified Glassy Carbon Electrode
    Chen, Xiaoping
    Ye, Huazhen
    Wang, Wanzong
    Qui, Bin
    Lin, Zhenyu
    Chen, Guonan
    ELECTROANALYSIS, 2010, 22 (20) : 2347 - 2352
  • [26] A glassy carbon electrode modified with electrochemically reduced graphene for simultaneous determination of guanine and adenine
    Zhu, Xiaohua
    Zeng, Lixuan
    Xu, Maotian
    Liang, Yong
    Nan, Junmin
    ANALYTICAL METHODS, 2012, 4 (09) : 2935 - 2939
  • [27] Novel Acetylcholinesterase Biosensor for Detection of Paraoxon Based on Holey Graphene Oxide Modified Glass Carbon Electrode
    Li, Yan Ping
    Zhao, Rui Xia
    Han, Gao Yi
    Xiao, Yao Ming
    ELECTROANALYSIS, 2018, 30 (10) : 2258 - 2264
  • [28] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [29] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [30] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154