Acetylcholinesterase Biosensor for the Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode

被引:16
|
作者
Jeyapragasam, Tharini [1 ]
Saraswathi, R. [2 ]
Chen, Shen-Ming [3 ]
Chen, Tse-Wei [3 ]
机构
[1] Rajarajan Inst Sci, Madurai, Tamil Nadu, India
[2] Madurai Kamaraj Univ, Sch Chem, Dept Mat Sci, Madurai, Tamil Nadu, India
[3] Natl Taipei Univ Technolgoy, Dept Chem Engn & Biotechnol, Taipei, Taiwan
来源
关键词
Pesticide biosensor; acetyl cholinesterase; methyl parathion; electrochemically reduced graphene oxide; Nafion; FUNCTIONALIZED GRAPHENE; ORGANOPHOSPHORUS; NANOPARTICLES; PESTICIDES; IMMOBILIZATION; NANOTUBES; CHOLINE;
D O I
10.20964/2017.06.77
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report the fabrication of a methyl parathion (MP) biosensor based on acetyl cholinesterase (AChE) immobilized on reduced graphene oxide (ERGO)-Nafion (Nf) modified glassy carbon electrode. ERGO-Nf acts as a biocompatible immobilization matrix for AChE for the analysis of MP. Electrochemical oxidation of acetylthiocholine chloride occurs at 0.7 V vs. Ag/AgCl in phosphate buffer solution (pH 7). Various experimental parameters such as effect of scan rate, MP concentration, acetylthiocholine chloride concentration, AChE loading and incubation time have been optimized for the sensor calibration. The calibration curve of MP has been constructed using square wave voltammetry in the concentration range of 2 x 10(-9) M to 7 x 10(-7) M and the sensor shows good reproducibility and stability. The sensor is found to have an estimated detection limit of 1 x 10(-9) M. The biosensor has been applied for the determination of methyl parathion in a vegetable sample.
引用
收藏
页码:4768 / 4781
页数:14
相关论文
共 50 条
  • [1] Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode
    Lin, Xiaoyun
    Ni, Yongnian
    Pei, Xueying
    Kokot, Serge
    ANALYTICAL METHODS, 2017, 9 (07) : 1105 - 1111
  • [2] Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide (ERGO) Modified Electrode
    Jeyapragasam, Tharini
    Saraswathi, Ramiah
    Chen, Shen-Ming
    Lou, Bih-Show
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (11): : 12353 - 12366
  • [3] Electrochemical Behavior and Determination of Matrine by the Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode
    Zhang, Hongjiao
    Xiong, Huabin
    Gao, Yuntao
    Wang, Zhengwei
    Li, Xiaofen
    Ma, Xiaoyan
    Yang, Hongqiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6348 - 6358
  • [4] Electrochemical Sensing of Acetaminophen on Electrochemically Reduced Graphene Oxide-Nafion Composite Film Modified Electrode
    Filik, Hayati
    Cetintas, Gamze
    Avan, A. Aslihan
    Koc, Serkan Naci
    Boz, Ismail
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (04): : 5724 - 5737
  • [5] Electrochemically Reduced Graphene Oxide-nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
    Lv, Yajie
    Wang, Fang
    Zhu, Hui
    Zou, Xiaorong
    Tao, Cheng-An
    Wang, Jianfang
    NANOMATERIALS AND NANOTECHNOLOGY, 2016, 6
  • [6] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Yong Kong
    Xiaolin Ren
    Zongli Huo
    Guoxin Wang
    Yongxin Tao
    Chao Yao
    European Food Research and Technology, 2013, 236 : 955 - 961
  • [7] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961
  • [8] Voltammetric Sensing of Bilirubin Based on Nafion/Electrochemically Reduced Graphene Oxide Composite Modified Glassy Carbon Electrode
    Avan, Asiye Aslihan
    Aydar, Sevda
    Filik, Hayati
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 96 - 103
  • [9] Electrochemical oxidation behavior of colchicine on a graphene oxide-Nafion composite film modified glassy carbon electrode
    Wang, Fei
    Zhou, Jing
    Liu, Yang
    Wu, ShengJiang
    Song, Ge
    Ye, Baoxian
    ANALYST, 2011, 136 (19) : 3943 - 3949
  • [10] Electrochemical Sensor Based on Nafion/Gold Nanoparticle/Electrochemically Reduced Graphene Oxide Composite-Modified Glassy Carbon Electrode for the Detection of Diuron
    Qin, Jianfang
    Qin, YingLian
    Jiang, Xiuping
    Du, Yajin
    Du, Yajing
    Yao, Chen-Zhong
    Wang, Xi
    Yang, Haiying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11203 - 11214