Modeling, measurement, and calibration of three-axis integrated aerial camera pointing errors

被引:5
|
作者
Liu, Hao [1 ]
Zhou, Xiaoqin [1 ]
Liu, Qiang [1 ]
Ma, Meng [1 ]
He, Xiuzhi [1 ]
Lin, Jieqiong [2 ]
机构
[1] Jilin Univ, Sch Mech & Aerosp Engn, Changchun 130025, Jilin, Peoples R China
[2] Changchun Univ Technol, Sch Mech Engn, Changchun 130012, Jilin, Peoples R China
关键词
three-axis integrated aerial camera; pointing error; semi-parametric model; error measurement; pointing calibration;
D O I
10.1088/1361-6501/abdef5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Aerial cameras are currently widely used in various fields. However, traditional aerial cameras have certain limitations. We propose a new three-axis integrated aerial camera that can significantly improve imaging efficiency. Both traditional aerial cameras and three-axis integrated aerial cameras suffer from reductions in image quality due to mechanical errors. In this paper, we analyze the influence of mechanical errors on pointing errors and establish a pointing parametric model (PM) based on spatial coordinate transformation and ray tracing. We also consider how the presence of nonlinear errors in aerial cameras affects image quality, and propose a semi-parametric model (SPM) to compensate for nonlinear errors. The PM and the SPM can be used to calibrate the pointing of aerial cameras. In addition, we propose an improved measurement method that can gauge the pointing errors that occur when the three-axis integrated aerial camera rotates to different angles. The results prove that both the PM and the SPM can effectively calibrate the pointing of the aerial camera. Following calibration using the SPM, the pointing errors were greatly reduced. The mean was reduced by more than two orders of magnitude, and the variance was reduced by 99.95%. The SPM completes the pointing calibration better than the PM.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A fully integrated three-axis thermal accelerometer
    Silva, C. S.
    Pontes, J.
    Viana, J. C.
    Rocha, L. A.
    Gaspar, J.
    2013 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2013, : 963 - 966
  • [22] Calibration of three-axis magnetometers with differential evolution algorithm
    Pang, Hongfeng
    Zhang, Qi
    Wang, Wei
    Wang, Junya
    Li, Ji
    Luo, Shitu
    Wan, Chengbiao
    Chen, Dixiang
    Pan, Mengchun
    Luo, Feilu
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2013, 346 : 5 - 10
  • [23] Spacecraft attitude determination and three-axis magnetometer calibration
    Huang, Lin
    Jing, Wu-Xing
    Yuhang Xuebao/Journal of Astronautics, 2008, 29 (03): : 854 - 859
  • [24] Calibration strategy and generality test of three-axis magnetometers
    Luo, Shitu
    Pang, Hongfeng
    Li, Ji
    Zhang, Qi
    Chen, Dixiang
    Pan, Mengchun
    Luo, Feilu
    MEASUREMENT, 2013, 46 (10) : 3918 - 3923
  • [25] Three-axis teslameter with integrated hall probe
    Popovic, Dragana R.
    Dimitrijevic, Sasa
    Blagojevic, Marjan
    Kejik, Pavel
    Schurig, Enrico
    Popovic, Radivoje S.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (04) : 1396 - 1402
  • [26] Field calibration of three-axis MEMS digital acceleration
    Peng, Xiaodong
    Zhang, Tiemin
    Li, Jiyu
    Yan, Guoqi
    Zhang, T. (tm-zhang@163.com), 1600, Nanjing University of Aeronautics an Astronautics (34): : 544 - 548
  • [27] Misalignment calibration method on multiple three-axis sensors
    Zhao H.
    Lin C.
    Zhang H.
    Zhang N.
    Zhai G.
    Lin, Chunsheng (lcs_and_zh@163.com), 2018, Science Press (39): : 144 - 151
  • [28] A Calibration Method of Three-Axis Magnetometer With Noise Suppression
    Song Zhongguo
    Zhang Jinsheng
    Zhang Xuehui
    Xi Xiaoli
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)
  • [29] Calibration method for sway error of three-axis fluxgate
    Xu, L.
    Yan, B.
    Liu, G. Q.
    Gu, H. C.
    Pang, Y. D.
    Luo, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08)
  • [30] Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
    Liu, Yan Xia
    Li, Xi Sheng
    Zhang, Xiao Juan
    Feng, Yi Bo
    SENSORS, 2014, 14 (05): : 8485 - 8504