Study of the monolithic x-ray focusing lens and its application in microbeam x-ray fluorescence analysis

被引:0
|
作者
Xie, JD [1 ]
Yan, YM [1 ]
Ding, XL [1 ]
He, YJ [1 ]
Pan, QL [1 ]
机构
[1] Beijing Normal Univ, Inst Low Energy Nucl Phys, Beijing 100875, Peoples R China
关键词
D O I
10.1002/1097-4539(200007/08)29:4<305::AID-XRS425>3.0.CO;2-Q
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A model of theoretical simulations of a monolithic x-ray focusing lens is described. These calculations are compared with experimental measurements of the lens. For the Mo K alpha line, a measured focal spot diameter of lens were about 30 mu m. Compared with an aperture of equivalent size located at the output focal distance without the lens, a power density gain of about 1500 was obtained. The application of the lens in microbeam x-ray fluorescence analysis reduced the minimum detection limits for transition elements down to the 10(-13) g level. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:305 / 309
页数:5
相关论文
共 50 条
  • [41] X-RAY FLUORESCENCE ANALYSIS
    OTTER, RJ
    MIKROCHIMICA ACTA, 1962, (05) : 983 - &
  • [42] X-RAY FLUORESCENCE ANALYSIS
    BAREHAM, FR
    GIDLEY, JAF
    BUTLER, DH
    LINDSTROM
    POWELL, AR
    JOHNSON, W
    FOX, JGM
    COCKETT, GH
    JOURNAL OF THE INSTITUTE OF METALS, 1962, 90 (07): : 273 - &
  • [43] X-ray Peltier cooled detectors for X-ray fluorescence analysis
    Loupilov, A
    Sokolov, A
    Gostilo, V
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 463 - 464
  • [44] X-RAY FLUORESCENCE ANALYSIS
    ROBERT, A
    BULLETIN DE LA SOCIETE FRANCAISE DE CERAMIQUE, 1968, (78): : 33 - &
  • [45] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [46] Development and optimization of microbeam X-ray fluorescence analysis of Sr in speleothems
    Buckles, Jessica
    Rowe, Harold D.
    CHEMICAL GEOLOGY, 2016, 426 : 28 - 32
  • [47] Application of laboratory micro X-ray fluorescence devices for X-ray topography
    Guguschev, Christo
    Hirschle, Christian
    Dadzis, Kaspars
    Kwasniewski, Albert
    Schulze, Michael
    Schellkopf, Leonard
    Richter, Carsten
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2024, 57 : 734 - 740
  • [48] Elemental depth profiling with a wire in microbeam X-ray fluorescence analysis
    Iida, Atsuo
    X-RAY SPECTROMETRY, 2011, 40 (05) : 376 - 378
  • [49] Study of the X-ray microbeam for scanning microscopes
    Iketaki, Y
    Horikawa, Y
    Mochimaru, S
    Nagai, K
    Kiyokura, T
    Oshima, M
    Yagishita, A
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 : 353 - 356
  • [50] The monolithic capillary X-ray lens and the measurement of its optical properties
    He, YJ
    Liu, AD
    Wei, FZ
    Wang, Y
    Luo, P
    Li, TH
    Yan, YM
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1997, 15 (04): : 641 - 645