Label-free immunosensor based on one-step electrodeposition of chitosan-gold nanoparticles biocompatible film on Au microelectrode for determination of aflatoxin B1 in maize

被引:101
|
作者
Ma, Haihua [1 ,2 ,3 ,4 ]
Sun, Jizhou [1 ]
Zhang, Yuan [1 ,4 ]
Bian, Chao [1 ]
Xia, Shanhong [1 ]
Zhen, Tong [3 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100190, Peoples R China
[3] Henan Univ Technol, Coll Informat Sci & Engn, Zhengzhou 450001, Peoples R China
[4] Henan Univ Technol, Key Lab Grain Informat Proc & Control, Minist Educ, Zhengzhou 450001, Peoples R China
来源
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Aflatoxin B-1; Microelectrode; Immunosensor; Chitosan; Gold nanoparticle; Electrodeposition; IMMOBILIZATION; MYCOTOXINS; BIOSENSOR; IMMUNOASSAY; OCHRATOXIN; HYDROGEL;
D O I
10.1016/j.bios.2016.01.063
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold nanoparticles (AuNPs) embedded in chitosan (CHI) film, well-dispersed and smaller in size (about 10 nm), were fabricated by one-step electrodeposion on Au microelectrode in solution containing chitosan and chloride trihydrate. The nano-structure CHI-AuNPs composite film offers abundant amine groups, good conductivity, excellent biocompatibility and stability for antibody immobilization. The combination of aflatoxin B-1 (AFB(1)) with immobilized antibody introduces a barrier to electron transfer, resulting in current decreasement. The morphologies and characterizations of modified microelectrodes were investigated by scanning electron microscope (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared spectroscopy (FT-IR). The proposed non enzyme and label-free immunosensor exhibited high sensitive amperometric response to AFB(1) concentration in two linear ranges of 0.1 to 1 ng mL(-1) and 1 to 30 ng mL(-1), with the detection limit of 0.06 ng mL(-1) (S/N=3). The immunoassay was also applied for analysis of maize samples spiked with AFB(1). Considering the sample extraction procedure, the linear range and limit of detection were assessed to be 1.6-16 ng mL(-1) and 0.19 ng mL(-1) respectively. The simple method showed good fabrication controllability and reproducibility for immunosensor design. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 37 条
  • [31] Label-free electrochemical immunosensor based on multi-functional gold nanoparticles-polydopamine-thionine-graphene oxide nanocomposites film for determination of alpha-fetoprotein
    Peng, Hua-Ping
    Hu, Yan
    Liu, Ai-Lin
    Chen, Wei
    Lin, Xin-Hua
    Yu, Xiang-Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 712 : 89 - 95
  • [32] Detection of aflatoxin B1 with a new label-free fluorescence aptasensor based on PVP-coated single-walled carbon nanohorns and SYBR Gold
    Xin Qi
    Lei Lv
    Dongxu Wei
    Jung Joon Lee
    Mengyu Niu
    Chengbi Cui
    Zhijun Guo
    Analytical and Bioanalytical Chemistry, 2022, 414 : 3087 - 3094
  • [33] Detection of aflatoxin B1 with a new label-free fluorescence aptasensor based on PVP-coated single-walled carbon nanohorns and SYBR Gold
    Qi, Xin
    Lv, Lei
    Wei, Dongxu
    Lee, Jung Joon
    Niu, Mengyu
    Cui, Chengbi
    Guo, Zhijun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (09) : 3087 - 3094
  • [34] Fabrication and modeling of an ultrasensitive label free impedimetric immunosensor for Aflatoxin B1 based on poly(o-phenylenediamine) modified gold 3D nano electrode ensembles
    Hu, Haifeng
    Cao, Lixin
    Li, Qingchuan
    Ma, Kan
    Yan, Peisheng
    Kirk, Donald W.
    RSC ADVANCES, 2015, 5 (68) : 55209 - 55217
  • [35] Fabrication and Modeling of an Ultrasensitive Label Free Impedimetric Immunosensor for Aflatoxin B1 based on Protein A Self-assembly Modified Gold 3D Nanotube Electrode ensembles
    Li, Xiaolong
    Cao, Lixin
    Zhang, Yuejuan
    Yan, Peisheng
    Kirk, Donald W.
    ELECTROCHIMICA ACTA, 2017, 247 : 1052 - 1059
  • [36] A sensitive and highly stable electrochemical impedance immunosensor based on the formation of silica gel-ionic liquid biocompatible film on the glassy carbon electrode for the determination of aflatoxin B1 in bee pollen
    Li Zaijun
    Wang Zhongyun
    Sun Xiulan
    Fang Yinjun
    Chen Peipei
    TALANTA, 2010, 80 (05) : 1632 - 1637
  • [37] Label-free impedimetric immunosensor based on one-step co-electrodeposited poly-(pyrrole-co-pyrrole-1-propionic acid) and reduced graphene oxide polymer modified layer for the determination of melamine
    Gu, Ying
    Wang, Junping
    Pan, Mingfei
    Li, Shijie
    Fang, Guozhen
    Wang, Shuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 571 - 578