In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: measurement in knee ligaments of adult rabbits

被引:24
|
作者
Forrester, K [1 ]
Doschak, M [1 ]
Bray, R [1 ]
机构
[1] Univ Calgary, Fac Med, McCraig Ctr Joint Injury & Arthrit Res, Calgary, AB T2N 4N1, Canada
基金
英国医学研究理事会;
关键词
blood flow; healing; injury; laser Doppler; ligament; joint; rabbits;
D O I
10.1007/BF02510964
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, there are only two laser Doppler perfusion imaging systems (LDIs) manufactured for medical applications:a 'stepwise' and a 'continuous' scanning LDI. The stepwise scanning LDI has previously been investigated and compared with coloured microsphere determined standardised flow. The continuous scanning LDI is investigated and compared with the stepwise scanning LDI for its ability to measure in vivo, hypoaemic, ligament tissue blood flow changes. The continuous scanning system was supplied with two lasers, red and near infrared (NIR), allowing for additional assessment of the effect of wavelength on imaging ligament perfusion. Perfusion images were obtained from surgically exposed rabbit medial collateral ligaments (MCL). Continuous and stepwise LDI scans were compared using correlation and linear regression analysis of image averages and standard deviations. Using the same method of analysis, LDI measurements using red and NIR lasers indicated a high degree of correlation, at least over the ranges of perfusion assessed, indicating that red and NIR lasers measure similar regions of flow in the rabbit MCL. These experiments confirm that both LDI techniques provide a valid in vivo measure of dynamic changes in connective tissue perfusion and could have significant impact on the understanding and treatment of joint injury and arthritis.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 50 条
  • [21] Laser Doppler perfusion imaging - A new technique for measuring breast skin blood flow
    Seifalian, AM
    Chaloupka, K
    Parbhoo, SP
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1995, 15 (03): : 125 - 130
  • [22] Evaluation of laser-Doppler perfusion imaging for measurement of blood flow in cortical bone
    Shymkiw, RC
    Zernicke, RF
    Forrester, KR
    Bray, RC
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (04) : 1314 - 1318
  • [23] COMPARISON OF LASER-DOPPLER PERFUSION IMAGING, LASER-DOPPLER FLOWMETRY, AND THERMOGRAPHIC IMAGING FOR ASSESSMENT OF BLOOD-FLOW IN HUMAN SKIN
    SEIFALIAN, AM
    STANSBY, G
    JACKSON, A
    HOWELL, K
    HAMILTON, G
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (01): : 65 - 69
  • [24] Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy
    Rasta, Seyed Hossein
    Manivannan, Ayyakkannu
    Sharp, Peter F.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [25] In-vivo-Differenzierung von pigmentierten Hauttumoren mittels Laser-Doppler-Perfusion-Imaging
    M. Stücker
    M. Hoffmann
    U. Memmel
    C. von Bormann
    K. Hoffmann
    P. Altmeyer
    Der Hautarzt, 2002, 53 : 244 - 249
  • [26] Scanning laser Doppler is a useful technique to assess foot cutaneous perfusion during femoral artery cannulation
    NicholasH Boyle
    PeterC Roberts
    Bernice Ng
    Haim Berkenstadt
    Angela McLuckie
    RichardJ Beale
    RobertC Mason
    Critical Care, 3
  • [27] Scanning laser Doppler is a useful technique to assess foot cutaneous perfusion during femoral artery cannulation
    Boyle, NH
    Roberts, PC
    Ng, B
    Berkenstadt, H
    McLuckie, A
    Beale, RJ
    Mason, RC
    CRITICAL CARE, 1999, 3 (04): : 95 - 100
  • [28] Blood Perfusion Values of Laser Speckle Contrast Imaging and Laser Doppler Flowmetry: Is a Direct Comparison Possible?
    Binzoni, Tiziano
    Humeau-Heurtier, Anne
    Abraham, Pierre
    Mahe, Guillaume
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) : 1259 - 1265
  • [29] In vivo comparison of a twin wavelength laser Doppler flowmeter using He-Ne and laser diode sources
    Obeid, A.N.
    Dougherty, G.
    Pettinger, S.
    Journal of Medical Engineering and Technology, 1990, 14 (03): : 102 - 110
  • [30] Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion
    Greco, Adelaide
    Ragucci, Monica
    Liuzzi, Raffaele
    Gargiulo, Sara
    Gramanzini, Matteo
    Coda, Anna Rita Daniela
    Albanese, Sandra
    Mancini, Marcello
    Salvatore, Marco
    Brunetti, Arturo
    SENSORS, 2013, 13 (01) : 500 - 515