In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: measurement in knee ligaments of adult rabbits

被引:24
|
作者
Forrester, K [1 ]
Doschak, M [1 ]
Bray, R [1 ]
机构
[1] Univ Calgary, Fac Med, McCraig Ctr Joint Injury & Arthrit Res, Calgary, AB T2N 4N1, Canada
基金
英国医学研究理事会;
关键词
blood flow; healing; injury; laser Doppler; ligament; joint; rabbits;
D O I
10.1007/BF02510964
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, there are only two laser Doppler perfusion imaging systems (LDIs) manufactured for medical applications:a 'stepwise' and a 'continuous' scanning LDI. The stepwise scanning LDI has previously been investigated and compared with coloured microsphere determined standardised flow. The continuous scanning LDI is investigated and compared with the stepwise scanning LDI for its ability to measure in vivo, hypoaemic, ligament tissue blood flow changes. The continuous scanning system was supplied with two lasers, red and near infrared (NIR), allowing for additional assessment of the effect of wavelength on imaging ligament perfusion. Perfusion images were obtained from surgically exposed rabbit medial collateral ligaments (MCL). Continuous and stepwise LDI scans were compared using correlation and linear regression analysis of image averages and standard deviations. Using the same method of analysis, LDI measurements using red and NIR lasers indicated a high degree of correlation, at least over the ranges of perfusion assessed, indicating that red and NIR lasers measure similar regions of flow in the rabbit MCL. These experiments confirm that both LDI techniques provide a valid in vivo measure of dynamic changes in connective tissue perfusion and could have significant impact on the understanding and treatment of joint injury and arthritis.
引用
收藏
页码:581 / 586
页数:6
相关论文
共 50 条
  • [1] In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: Measurement in knee ligaments of adult rabbits
    K. Forrester
    M. Doschak
    R. Bray
    Medical and Biological Engineering and Computing, 1997, 35 : 581 - 586
  • [2] In vivo comparison of scanning technique and wavelength in laser Doppler perfusion imaging: Measurement in knee ligaments of adult rabbits
    Department of Surgery, McCraig Ctr. Jt. Inj. Arthr. Res., University of Calgary, 3330 Hospital Drive N.W, Calgary, Alta. T2N 4NI, Canada
    不详
    不详
    MED. BIOL. ENG. COMPUT., 6 (581-586):
  • [3] Evaluation of laser Doppler imaging to measure blood flow in knee ligaments of adult rabbits
    Bray, R
    Forrester, K
    McDougall, JJ
    Damji, A
    Ferrell, WR
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (03) : 227 - 231
  • [4] Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement
    Guven, Goksel
    Dijkstra, Annemieke
    Kuijper, Tjallingius Martijn
    Trommel, Nicole
    van Baar, Margriet Elisabeth
    Topeli, Arzu
    Ince, Can
    van der Vlies, Cornelis Hendrik
    MICROCIRCULATION, 2023, 30 (01)
  • [5] Laser Doppler imaging of burn scars: a comparison of wavelength and scanning methods
    Bray, R
    Forrester, K
    Leonard, C
    McArthur, R
    Tulip, J
    Lindsay, R
    BURNS, 2003, 29 (03) : 199 - 206
  • [6] Comparison of scanning beam and whole field laser Doppler perfusion imaging
    Steenbergen, Wiendelt
    Hondebrink, Erwin
    van Leeuwen, Ton G.
    Draijer, Matthijs J.
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VII, 2010, 7563
  • [7] Characteristics of laser Doppler perfusion imaging in vitro and in vivo
    Kernick, DP
    Shore, AC
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) : 333 - 340
  • [8] Measurement of depth of burns by laser Doppler perfusion imaging
    Droog, EJ
    Steenbergen, W
    Sjöberg, F
    BURNS, 2001, 27 (06) : 561 - 568
  • [9] Comparison of laser speckle and laser Doppler perfusion imaging: measurement in human skin and rabbit articular tissue
    Forrester, KR
    Stewart, C
    Tulip, J
    Leonard, C
    Bray, RC
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (06) : 687 - 697
  • [10] Comparison of laser speckle and laser Doppler perfusion imaging: Measurement in human skin and rabbit articular tissue
    K.R. Forrester
    C. Stewart
    J. Tulip
    C. Leonard
    R.C. Bray
    Medical and Biological Engineering and Computing, 2002, 40 : 687 - 697