Bent Laue crystal monochromator for producing areal x-ray beams

被引:0
|
作者
Zhong, Z [1 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source Dept, Upton, NY 11973 USA
关键词
BARIUM; CERIUM; K SHELL; KEV RANGE 10-100; LAUE METHOD; MONOCHROMATORS; SYNCHROTRON RADIATION SOURCES; TUNING; X-RAY EQUIPMENT; X-RAY RADIOGRAPHY;
D O I
10.1118/1.598136
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bent Laue crystal monochromator for diffraction of areal monochromatic x-ray beams from a polyenergetic x-ray rotating anode source has been developed at the National Synchrotron Light Source (NSLS). The monochromatic beam, with a solid angle of more than 5 degrees×5 degrees and energy range tunable from 15 keV to 100 keV, is completely separated from the white beam at a distance of less than 1 m from the source. The absolute reflectivity of the monochromator ranges from 10% to 40%, depending on the energy of the x rays being diffracted and on the source size. The energy bandwidth, around 2%, is controllable by varying the diffraction planes used, the crystal thickness, the asymmetry angle and the bending radius. A single emission line from an x-ray tube source can be selectively diffracted into the entire exit-beam solid angle. The monochromator was tested using a compact rotating anode x-ray source at Science Research Laboratory (SRL). The [formula omitted]-alpha characteristic lines (both [formula omitted]-alpha1 and [formula omitted]-alpha2) of cerium and barium targets were diffracted by the monochromator and used for the above and below iodine [formula omitted]-edge imaging of phantoms with several concentrations of iodine contrast agent. Digital subtraction of the images produced an iodine image. The potential applications of the device in clinical radiography are discussed. © 1997, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2055 / 2055
页数:1
相关论文
共 50 条
  • [21] A SINGLE-CRYSTAL BENT LAUE MONOCHROMATOR FOR CORONARY ANGIOGRAPHY
    SUORTTI, P
    THOMLINSON, W
    CHAPMAN, D
    GMUR, N
    SIDDONS, DP
    SCHULZE, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 304 - 309
  • [22] A SIMPLE X-RAY CRYSTAL MONOCHROMATOR
    MILLAR, JJ
    BARNEA, Z
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1970, 3 (07): : 570 - &
  • [23] A bent Laue crystal monochromator for monochromatic radiography with an area beam
    Zhong, Z
    Chapman, D
    Thomlinson, W
    Arfelli, F
    Menk, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3): : 489 - 498
  • [24] Bent Laue crystal monochromator for monochromatic radiography with an area beam
    Zhong, Z.
    Chapman, D.
    Thomlinson, W.
    Arfelli, F.
    Menk, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 399 (2-3): : 489 - 498
  • [25] A SIMPLE METHOD FOR OBTAINING A BENT LIF X-RAY MONOCHROMATOR
    OHSHIMA, KI
    TANAKA, M
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1981, 14 (FEB) : 75 - 75
  • [26] A High Quality Bent Crystal Monochromator based on Asymmetric Laue Geometry
    Hu, Hua-Chen
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C142 - C142
  • [27] A BENT CRYSTAL X-RAY SPECTROGRAPH
    DEODHAR, GB
    KARNATAK, RC
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1957, 34 (01): : 21 - 23
  • [28] Bent crystal X-ray optics
    Förster, E.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2007, 15 (12): : 1823 - 1828
  • [29] BENT CRYSTAL X-RAY MONOCHROMATORS
    WARREN, BE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (01): : 102 - 102
  • [30] BENT CRYSTAL X-RAY SPECTROGRAPH
    BOSTER, TA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (04): : 546 - &