Cyclic loading of implant-supported prostheses: Changes in component fit over time

被引:84
|
作者
Hecker, DM
Eckert, SE
机构
[1] Univ Minnesota, Sch Dent, Maxillofacial Prosthet Serv, Minneapolis, MN 55455 USA
[2] Mayo Clin & Mayo Grad Sch Med, Rochester, MN 55901 USA
[3] Univ Minnesota, Sch Dent, Dept Restorat Sci, Minneapolis, MN 55455 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 89卷 / 04期
关键词
D O I
10.1067/mpr.2003.71
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Dental literature suggests that an implant-supported prosthesis must exhibit a passive fit to prevent implant fracture, component breakage, and screw loosening. From a practical standpoint, passive fit is impossible to achieve; instead, minimal misfit may be the clinical goal. To date no specific range of misfit (below which problems are minimal and above which catastrophic failure occurs) has been established. Purpose. The purpose of this study was to determine whether the fit of an implant-supported prosthesis changes through cyclic loading and to quanti, the amount of change between the gold cylinder and implant abutment over time. Materials and methods. Fifteen implant-supported frameworks were fabricated with conventional casting techniques and were cyclically loaded under 3 different loading conditions. Five frameworks were loaded on the anterior portion of the framework, 5 were loaded on the left unilateral posterior cantilever, and 5 were loaded bilaterally on the posterior cantilevers with a servohydraulic testing machine. A cyclical load of 200 N was applied to each framework for up to 200,000 cycles. Linear measurements were made in micrometers of the gap between the prosthetic cylinder and the implant-supported abutment at 4 predetermined reference points. These measurements were recorded before the application of the cyclical load, after 50,000 cycles, and after 200,000 cycles. A repeated measures of variance model was fit separately to the data for each load location (P<.05). Results. There was a significant (P=.024) decrease in gap dimensions at individual reference points and a significant (P=.031) decrease in the average gap when the load was applied to the anterior portion of the framework. When the load was applied unilaterally or bilaterally on the posterior cantilever, significant gap closure was not observed (P=.33 and P=.35, respectively). Conclusion. Within the limitations of this study, the fit between the prosthetic superstructure and the implant-supported abutment changed when simulated functional loading of the anterior portion of the prosthesis was performed. Simulated functional loading applied unilaterally or bilaterally to the posterior cantilever portion of the prosthesis did not result in changes in the measured gap sizes.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 50 条
  • [21] Evaluation of the marginal fit of implant-supported crowns
    Akmal N.L.H.B.I.
    Duraisamy R.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (03): : 165 - 172
  • [22] In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after cyclic loading
    Sananez, Andreina
    Lefebvre, Carol
    Looney, Stephen
    Baker, Philip
    Mettenburg, Don
    Rueggeberg, Frederick A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05): : 432 - 439
  • [23] Digital Impressions for Implant-Supported Fixed Dental Prostheses
    Lee S.J.
    Lee J.D.
    Current Oral Health Reports, 2017, 4 (2) : 136 - 141
  • [24] A Study on Materials Used and Longevity of Implant-Supported Prostheses
    Perti, Sonali
    Singh, Rashi
    Choithani, Kishan K.
    Duseja, Sareen
    Mitthra, Suresh
    Dewan, Harisha
    Tiwari, Rahul
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2730 - S2732
  • [25] IMPLANT-SUPPORTED FIXED DISTAL-EXTENSION PROSTHESES
    WATSON, RM
    DAVIS, DM
    ECKHARDT, P
    NEWMAN, P
    ROGERS, JO
    BRITISH DENTAL JOURNAL, 1994, 176 (09) : 351 - 355
  • [26] Implant-supported fixed partial prostheses:: A retrospective study
    Johansson, LÅ
    Ekfeldt, A
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (02) : 172 - 176
  • [27] Completely implant-supported telescopic maxillofacial prostheses.
    Weischer, T
    Mohr, C
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 296 - 296
  • [28] Cement retention for retrievable implant-supported prostheses.
    Alfaro, MA
    Papazoglou, E
    Beck, M
    McGlumphy, EA
    Holloway, JA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 530 - 530
  • [29] Implant-supported fixed and removable prostheses in the fibular mandible
    Nguyen, Truc Thi Hoang
    Eo, Mi Young
    Myoung, Hoon
    Kim, Myung-Joo
    Kim, Soung Min
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [30] Study of occlusal patterns in completely implant-supported prostheses
    Tortamano, P
    Saito, T
    Boruszewski, W
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1180 - 1180