Use of intraoperative sodium fluorescein for diagnostic tissue biopsy of spinal cord lesions

被引:5
|
作者
Ung, Timothy H. [1 ,2 ]
Robinson, Leslie C. [1 ]
Nevzati, Edin [1 ]
Harasaki, Yasuaki [1 ,2 ]
Ormond, D. Ryan [1 ]
Lillehei, Kevin O. [1 ]
Witt, Jens-Peter [1 ,2 ]
Finn, Michael [1 ,2 ]
机构
[1] Univ Colorado, Sch Med, Dept Neurol Surg, Aurora, CO 80045 USA
[2] Univ Colorado Hosp, Spine Ctr, Aurora, CO 80045 USA
来源
INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT | 2019年 / 18卷
关键词
Fluorescein sodium; Fluorescence-guided spinal surgery; Spinal tumor resection; Spine tumor biopsy; GROSS-TOTAL RESECTION; GUIDED RESECTION; GLIOBLASTOMA-MULTIFORME; SURGERY; MICROSCOPE; ANGIOGRAPHY; ANAPHYLAXIS; GLIOMA; FILTER;
D O I
10.1016/j.inat.2019.100541
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Recent evidence suggests that fluorescein-guided microsurgery facilitates resection of intrinsic and metastatic lesions in the brain. Use of sodium fluorescein for angiography has previously been reported without non-specific diffusion into the adjacent spinal parenchyma. Diagnostic biopsy of spinal cord lesion is often challenging and the localization of such lesions intraoperatively is paramount. We present the first known report of use of sodium fluorescein for localization and diagnostic biopsy of intrinsic spinal cord lesions. Methods: Three patients with spinal cord lesions received fluorescein sodium 10% (Alcon Laboratories INC, Fort Worth, TX, USA) at 3 mg/kg prior to surgical resection. Intraoperative visualization of fluorescence was performed using a Zeiss Pentero (Carl Zeiss AG, Oberkochen, Germany) microscope equipped with a Yellow560 filter or a Leica OH6 (Leice Microsystems, Wetzlar, Germany) equipped with a FL560 filter. Results: Administration of sodium fluorescein resulted in lesional fluorescent contrast extravasation and facilitated surgical resection. The addition of sodium fluorescein allowed for identification and facilitated biopsy in three patients. In patients undergoing biopsy, tissue samples were positive for a diagnostic pathology. Conclusion: Fluorescein may be a helpful microsurgical tool in guiding resection and localization for tissue biopsy of intramedullary spinal lesions. Further research is necessary to explore fluorescein sodium applications in the resection of spinal cord lesions.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Delayed variations in the diagnostic accuracy of intraoperative neuromonitoring in the resection of intramedullary spinal cord tumors
    Kimchi, Gil
    Knoller, Nachshon
    Korn, Akiva
    Eyal-Mazuz, Yahel
    Sapir, Yechiam
    Peled, Anton
    Harel, Ran
    NEUROSURGICAL FOCUS, 2020, 50 (05) : 1 - 7
  • [32] Multimodal Intraoperative Spinal Cord Monitoring during Spinal Deformity Surgery: Efficacy, Diagnostic Characteristics, and Algorithm Development
    Tsirikos, Athanasios, I
    Duckworth, Andrew D.
    Henderson, Lindsay E.
    Michaelson, Clara
    MEDICAL PRINCIPLES AND PRACTICE, 2020, 29 (01) : 6 - 17
  • [33] Intraoperative Use of Indocyanine Green Fluorescence Videography for Resection of a Spinal Cord Hemangioblastoma
    Hwang, Steven W.
    Malek, Adel M.
    Schapiro, Robert
    Wu, Julian K.
    NEUROSURGERY, 2010, 67 (03) : 300 - 302
  • [34] IMAGING OF CYSTIC AND CAVITARY LESIONS OF THE SPINAL-CORD AND CANAL - THE VALUE OF MR AND INTRAOPERATIVE SONOGRAPHY
    KOCHAN, JP
    QUENCER, RM
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1991, 29 (04) : 867 - 911
  • [35] Results of Intraoperative Sodium Fluorescein Video Angiography and Its Repeated Use in a Series of Brain Aneurysm Surgeries
    Postalci, Lutfi Sinasi
    Erkan, Buruc
    TURKISH NEUROSURGERY, 2023, 33 (05) : 828 - 839
  • [36] A retrospective study of spinal cord lesions in goats submitted to 3 veterinary diagnostic laboratories
    Allen, Andrew L.
    Goupil, Brad A.
    Valentine, Beth A.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2012, 53 (06): : 639 - 642
  • [37] The use of the sodium fluorescein and YELLOW 560 nm filter for the resection of pediatric posterior fossa lesions
    Ott, Christian
    Proescholdt, Martin
    Friedrich, Monika
    Hoehne, Julius
    Rosengarth, Katharina
    Schmidt, Nils-Ole
    Schebesch, Karl-Michael
    CHILDS NERVOUS SYSTEM, 2023, 39 (06) : 1495 - 1500
  • [38] The use of the sodium fluorescein and YELLOW 560 nm filter for the resection of pediatric posterior fossa lesions
    Christian Ott
    Martin Proescholdt
    Monika Friedrich
    Julius Hoehne
    Katharina Rosengarth
    Nils-Ole Schmidt
    Karl-Michael Schebesch
    Child's Nervous System, 2023, 39 : 1495 - 1500
  • [39] Experimental use of somatosensory evoked potential for intraoperative identification of spinal cord blood supply
    Janusz, MT
    Qayumi, AK
    Jamieson, WRE
    Fairholm, DJ
    JOURNAL OF INVESTIGATIVE SURGERY, 1997, 10 (04) : 195 - 203
  • [40] Intraoperative Use of Indocyanine Green Fluorescence Videography for Resection of a Spinal Cord Hemangioblastoma COMMENTS
    Mahan, Mark
    Spetzler, Robert F.
    Benzel, Edward C.
    Kaiser, Michael G.
    NEUROSURGERY, 2010, 67 (03) : 302 - 303