Anatomic factors affecting microkeratome placement in laser in situ keratomileusis

被引:8
|
作者
Booranapong, W [1 ]
Malathum, P [1 ]
Slade, SG [1 ]
机构
[1] Ctr Laser, Houston, TX 77027 USA
来源
关键词
D O I
10.1016/S0886-3350(00)00502-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify the significant anatomic factors that affect placement of 2 microkeratomes and compare the ease of their placement. Setting: The Laser Center, Houston, Texas, USA. Methods: Anatomic factors affecting microkeratome placement were evaluated in 250 eyes of 137 myopic patients in a prospective consecutive-enrollment study. Anatomic factors measured included vertical orbital width, horizontal interpalpebral fissure (HPF), corneal diameter, and position of the corneal apex relative to the lateral orbital rim (PCL). Vertical orbital width and HPF were measured with a micrometer caliper (Mitutoyo); corneal diameter, with Orbscan topography (Bausch & Lomb Surgical); and PCL, with a Hertel exophthalmometer. Patients were randomly divided into 2 groups (125 eyes/group) to have surgery with the Automated Corneal Shaper(R) (ACS) (Bausch & Lomb Surgical) or Hansatome (Bausch & Lomb Surgical) microkeratome. Microkeratome placement was graded by 1 surgeon as "easy" (grades 1, 2, and 3) or "difficult" (grades 4 and 5). Results were correlated with anatomic factors to evaluate possible anatomic influences on the difficulty of microkeratome placement. Results: The PCL and vertical orbital width were statistically significant factors in predicting the difficulty of ACS microkeratome placement (P < .05). For the Hansatome microkeratome, since only 1 eye was graded as a difficult placement, the anatomic parameters affecting placement could not be evaluated. There were no statistically significant between-group differences in mean age and means of all anatomic factors measured (independent t test, P > .05). Difficult applanations were encountered in the ACS group (8/125 eyes, 6.4%) more than in the Hansatome group (1/125 eyes, 0.8%), which was a statistically significant difference by the Pearson chi-square test (P < .05). Conclusions: The PCL and vertical orbital width were significant anatomic factors affecting placement of the ACS microkeratome. The anatomic factors affecting Hansatome microkeratome placement could not be determined. The percentage of difficult placements was significantly lower with the Hansatome than with the ACS. (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:1319 / 1325
页数:7
相关论文
共 50 条
  • [41] Laser in situ keratomileusis flap complications using mechanical microkeratome versus femtosecond laser: Retrospective comparison
    Moshirfar, Majid
    Gardiner, Jeffrey P.
    Schliesser, Joshua A.
    Espandar, Ladan
    Feiz, Vahid
    Mifflin, Mark D.
    Chang, Joann C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (11): : 1925 - 1933
  • [42] Thin-Flap Laser In Situ Keratomileusis-Associated Dry Eye: A Comparative Study Between Femtosecond Laser and Mechanical Microkeratome-Assisted Laser In Situ Keratomileusis
    Abdel-Radi, Mahmoud
    Abdelmotaal, Hazem
    Anwar, Mohamed
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (01): : 20 - 26
  • [43] Risk factors for early flap misalignment following microkeratome-assisted laser in situ keratomileusis: A retrospective large database analysis
    Friehmann, Asaf
    Mimouni, Michael
    Assad, Negme
    Rabina, Gilad
    Spierer, Oriel
    Nemet, Achia
    Kaiserman, Igor
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 385 - 389
  • [44] COMPARATIVE-STUDY OF LASER AND MICROKERATOME INSITU KERATOMILEUSIS
    BECHARA, SJ
    WARING, GO
    THOMPSON, KP
    GROSSNIKLAUS, HE
    KIM, EK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 799 - 799
  • [45] Corneal flap thickness in laser in situ keratomileusis using the Summit Krumeich-Barraquer microkeratome
    Uçakhan, OO
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 798 - 804
  • [46] Corneal flap thickness in laser in situ keratomileusis using the Moria M2 microkeratome
    Muallem, MS
    Yoo, SY
    Romano, AC
    Schiffman, JC
    Culbertson, WW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09): : 1902 - 1908
  • [47] Subbasal Nerve Density and Corneal Sensitivity After Laser In Situ Keratomileusis Femtosecond Laser vs Mechanical Microkeratome
    Patel, Sanjay V.
    McLaren, Jay W.
    Kittleson, Katrina M.
    Bourne, William M.
    ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (11) : 1413 - 1419
  • [48] Differences in the corneal biomechanical effects of surface ablation compared with laser in situ keratomileusis using a microkeratome or femtosecond laser
    Hamilton, D. Rex
    Johnson, R. Duncan
    Lee, Nancy
    Bourla, Nirit
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12): : 2049 - 2056
  • [49] Clinical analysis of the neodymium:YLF picosecond laser as a microkeratome for laser in situ keratomileusis -: Partially sighted eye study
    Krueger, RR
    Marchi, V
    Gualano, A
    Juhasz, T
    Speaker, M
    Suarez, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (11): : 1434 - 1440
  • [50] Inadvertent inversion of corneal flap following microkeratome-assisted laser-assisted in situ keratomileusis
    Sharma, Ashok
    Sharma, Rajan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3031 - 3032