Performance of the Fourier rebinning algorithm for PET with large acceptance angles

被引:42
|
作者
Matej, S [1 ]
Karp, JS [1 ]
Lewitt, RM [1 ]
Becher, AJ [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 04期
关键词
D O I
10.1088/0031-9155/43/4/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recently proposed Fourier rebinning (FORE) technique of 3D PET reconstruction is investigated over a wide range of axial acceptance angles. In this study we evaluate the performance of the FORE technique using spatial resolution, contrast and noise figures of merit and compare reconstruction performance of the FORE (followed by multislice 2D reconstruction) to the 3D-RP technique for large-acceptance-angle data (+/-26.25 degrees). Our results show that the FORE technique does not affect the transverse resolution. On the other hand the axial resolution using FORE deteriorates faster, compared with the 3D-RP, at large radii as the acceptance angle increases. Concerning the noise behaviour, we have found that filtering has better ability to suppress the noise in the FORE reconstruction, compared with the 3D-RP reconstruction, especially in the slices near the edge of the axial field of view. Overall, the combination of good performance and fast reconstruction time makes the FORE technique a practical choice for 3D PET applications.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 50 条
  • [21] Performance Improvements in Microsystems Enabled Photovoltaics with Wider Acceptance Angles
    Agrawal, Gautam
    Lentine, Anthony L.
    Gu, Tian
    Nielson, Gregory N.
    Haney, Michael W.
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 444 - 449
  • [22] Fully-3D binning and Fourier-space rebinning of PET data acquired with rotating planar detectors.
    Kadrmas, DJ
    Di Bella, EV
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 196P - 196P
  • [23] Optimized Weighting for Fourier Rebinning of Three-Dimensional Time-of-Flight PET Data to Non-Time-of-Flight
    Ahn, Sangtae
    Cho, Sanghee
    Li, Quanzheng
    Leahy, Richard M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2989 - 2996
  • [24] A GPU-based Architecture for Improved Online Rebinning Performance in Clinical 3-D PET
    Patlolla, Dilip R.
    Breeding, Eric
    Jones, William F.
    Everman, Jimmy
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3135 - 3139
  • [25] Simultaneous multiple surface concentrators for large acceptance angles and gap losses control
    Canavarro, Diogo
    Chaves, Julio
    Borges, Henry
    Santos, Andre
    Collares-Pereira, Manuel
    OPTIK, 2021, 242
  • [26] Iterative image reconstruction using inverse Fourier rebinning for fully 3-D PET (vol 26, pg 347, 2007)
    Cho, Sanghee
    Li, Quanzheng
    Ahn, Sangtae
    Bai, Bing
    Leahy, Richard M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (05) : 745 - 756
  • [27] PET scanner performance: Quality assurance and acceptance testing
    Kemp, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2074 - 2074
  • [28] PET scanner performance, quality assurance and acceptance testing
    Kemp, B
    MEDICAL PHYSICS, 2004, 31 (06) : 1765 - 1765
  • [29] A new weighted multi-slice rebinning algorithm using orthogonal projection in 3D PET.
    Hsu, C
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 214P - 214P
  • [30] PERFORMANCE OF AN ENERGY COMPENSATOR WITH A LARGE ACCEPTANCE ANGLE
    ANDREN, HO
    JOURNAL DE PHYSIQUE, 1986, 47 (C-7): : 483 - 488