Large-Area, Low-Cost, High-Efficiency Neutron Detector for Vehicle-Mounted Operation

被引:2
|
作者
Lacy, Jeffrey L. [1 ]
Martin, Christopher S. [1 ]
Athanasiades, Athanasios [1 ]
Regmi, Murari [1 ]
Vazquez-Flores, Gerson J. [1 ]
Davenport, Stephen [1 ]
King, Nicholas S. [1 ]
Lyons, Tom [1 ]
机构
[1] Proport Technol Inc, Houston, TX 77045 USA
关键词
Detector instrumentation; gamma rays; neutrons; radiation detectors; RADIATION; STRAWS;
D O I
10.1109/TNS.2016.2631451
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a large-area, low-cost, high-efficiency neutron detector for vehicle-mounted operation. The detector, which has overall dimensions 12.7 cm x 91.4 cm x 102 cm (5" x36" x40"), a sensitive area equal to 0.85 m(2) (1320 in(2)), and weight of 110 kg (242 lbs), employs an array of 90 boron-coated straw (BCS) detectors. PTI has also developed electronics to minimize cost and space while providing low-noise signal conditioning for both neutron and gamma detection channels, as well as low energy Bluetooth communication with handheld devices. Extremely low power consumption allows continuous use for 225 hours (similar to 10 days) using three AAA lithium-ion rechargeable batteries. We present radiological, mechanical, and environmental tests, collected from four full-scale prototypes. Outdoor neutron-counting tests with a moderated Cf-252 source 2 m away from the center of the detector face showed an average detection rate of 5.5 cps/ng with a standard deviation of 0.09 cps/ng over the four individual detector measurements. Measurements showed a gamma rejection ratio of 1.0 x 10(-8), and gamma absolute rejection ratio (GARRn) of 0.93. The prototypes were also operated successfully onboard a moving vehicle for high-speed tests and a long-range 1433-mile, two-day road trip from Houston, TX, USA, to Laurel, MD, USA. Using auxiliary DARPA SIGMA equipment, the GPS, timestamp, gamma and neutron data were transmitted over the cellular network with 10 Hz resolution to a server and real-time tracking website. Mechanical impact and electrostatic discharge testing produced no spurious counts in either the neutron or gamma channels. Ambient environmental temperature testing showed less than +/- 1% response variation over the range from -30 degrees C to + 55 degrees C.
引用
收藏
页码:1696 / 1703
页数:8
相关论文
共 50 条
  • [41] Design Issues and Possible Solutions for Low-Cost and High-Efficiency LSIs
    Mizuno, Masayuki
    2009 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, 2009, : 417 - 417
  • [42] A low-cost, high-efficiency and durable homogeneous system for molecular hydrogen
    Liu, Qifeng
    Liu, Bingrui
    Zhang, Qian
    Gao, Jianping
    Ma, Jingjun
    MATERIALS LETTERS, 2018, 221 : 46 - 50
  • [43] Rapid processing of low-cost, high-efficiency silicon solar cells
    A Rohatgi
    P Doshi
    A Ebong
    S Narasimha
    T Krygowski
    J Moschner
    Bulletin of Materials Science, 1999, 22 : 383 - 390
  • [44] BIFACIAL SOLAR-CELLS ON LARGE-AREA LOW-COST SILICON-WAFERS
    SILARD, A
    NANI, G
    IEEE ELECTRON DEVICE LETTERS, 1988, 9 (01) : 20 - 22
  • [45] Large-area, low-cost, highly durable solar evaporators for sustainable solarizing seawater
    Zhao, Xinping
    Wang, Ziman
    Li, Jie
    Wang, Haiyang
    Xing, Shijie
    Ji, Zhi-yong
    Zhang, Panpan
    CHEMICAL ENGINEERING JOURNAL, 2024, 494
  • [46] Development of Low-cost and Large-area Nanopatterned Vitreous Carbon Stamp for Glass Nanoreplication
    Ju, Jonghyun
    Han, Yunah
    Seok, Jongwon
    Kim, Seok-min
    2012 12TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2012,
  • [47] Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
    Perez, Kerstin
    Aramaki, Tsuguo
    Hailey, Charles J.
    Carr, Rachel
    Erjavec, Tyler
    Fuke, Hideyuki
    Garvin, Amani
    Harper, Cassia
    Kewley, Glenn
    Madden, Norman
    Mechbal, Sarah
    Rogers, Field
    Saffold, Nathan
    Tajiri, Gordon
    Tokuda, Katsuhiko
    Williams, Jason
    Yamada, Minoru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 905 : 12 - 21
  • [48] Large-Area and Low-Cost Force/Tactile Capacitive Sensor for Soft Robotic Applications
    Pagoli, Amir
    Chapelle, Frederic
    Corrales-Ramon, Juan-Antonio
    Mezouar, Youcef
    Lapusta, Yuri
    SENSORS, 2022, 22 (11)
  • [49] The development of a low-cost large-area high-resolution breast positron emission mammography (PEM) camera
    Zhang, Yuxuan
    Ramirez, Racio
    Li, Hongdi
    Liu, Shitao
    An, Shaohui
    Wang, Chao
    Baghaei, Hossain
    Wong, Wai-Hoi
    Jan, Meei-Ling
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [50] Large-area Low-cost Substrate Compatible CNT Schottky Diode for THz Detection
    Yang, Xianbo
    Chahal, Prem
    2011 IEEE 61ST ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2011, : 2158 - 2164