FEERIC, a very-front-end ASIC for the ALICE Muon Trigger Resistive Plate Chambers

被引:0
|
作者
Manen, S. [1 ]
Dupieux, P. [1 ]
Joly, B. [1 ]
Jouve, F. [1 ]
Vandaele, R. [1 ]
机构
[1] LPC Clermont Ferrand, Clermont Ferrand, France
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ALICE Collaboration at the CERN-LHC has started a vast program of upgrades in the context of the increase of the luminosity of the LHC from 2018 on. The present very front-end electronics (VFE) of the Muon Trigger, whose acronym is ADULT, must be replaced to prevent the aging of the Resistive Plate Chamber (RPC) detector in the future expected operating conditions. The new VFE, FEERIC (Front-End Electronics Rapid Integrated Circuit), will have to perform amplification of the analog input signal (this is not the case for ADULT). This will allow for RPC operation in a low-gain avalanche mode, with a much smaller (factor 3-5) charge deposit in the detector with respect to the present conditions. The purpose is to discriminate RPC signals with a charge threshold around 100 fC, in both polarities. The VFE system consists of 21,000 channels, distributed over 2400 electronics cards equipped with one or two ASICs. A total of 3000 ASICs of 8 channels each is necessary. The future ASIC has to insure mainly the following functions: amplification, discrimination and LVDS output stage. FEERIC will be capable of handling bipolar signals varying from +/- 20 fC up to +/- 3 pC with a fixed threshold of typically 100 fC. A prototype chip has been designed using the 0.35 mu m CMOS technology of AMS. The time resolution is less than 500 ps rms for an input charge of +/- 100 fC. The time resolution is 30 ps rms for an input charge of +/- 3 pC. The cross-talk is less than 2% for an input charge of +/- 3.5 pC and a threshold of +/- 20 mV (corresponding to approximate to 70 fC). The global power consumption per channel is 60 mW, with a 3 V power supply.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Experience gained about Resistive Plate Chambers ageing from the ALICE Muon TRigger/IDentifier detector
    Ferretti, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1068
  • [2] Final results of the tests on the resistive plate chambers for the ALICE muon arm
    Arnaldi, R.
    Baldit, A.
    Barret, V.
    Bastid, N.
    Blanc, A.
    Blanchard, G.
    Chiavassa, E.
    Cortese, P.
    Crochet, P.
    Dellacasa, G.
    De Marco, N.
    Devaux, A.
    Dupieux, P.
    Ferretti, A.
    Gallio, M.
    Gemme, R.
    Grygorian, S.
    Insa, C.
    Jouve, F.
    Lopez, X.
    Manceau, L.
    Manso, F.
    Mereu, P.
    Musso, A.
    Oppedisano, C.
    Piccotti, A.
    Poggio, F.
    Rosnet, P.
    Royer, L.
    Saturnini, P.
    Scomparin, E.
    Stocco, D.
    Vercellin, E.
    Vulpescu, B.
    Yermia, F.
    Gagliardi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (03): : 740 - 743
  • [3] Commissioning and first performance of the resistive plate chambers for the ALICE muon arm
    Gagliardi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 : S45 - S49
  • [4] Aging study for resistive plate chambers of the CMS muon trigger detector
    Abbrescia, M
    Colaleo, A
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Altieri, S
    Belli, G
    Bruno, G
    Guida, R
    Ratti, SP
    Riccardi, C
    Torre, P
    Vitulo, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 515 (1-2): : 342 - 347
  • [5] A prototype front end chip for the CMS resistive plate chambers
    Abbrescia, M
    Colaleo, A
    Guarrasi, L
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Altieri, S
    Belli, G
    Bruno, G
    Gianini, G
    Ratti, SP
    Riccardi, C
    Torre, P
    Viola, L
    Vitulo, P
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 457 - 461
  • [6] Aging tests and chemical analysis of Resistive Plate Chambers for the trigger of the ALICE dimuon arm
    Arnaldi, R
    Chiavassa, E
    Colla, A
    Cortese, P
    Dellacasa, G
    De Marco, N
    Ferretti, A
    Gallio, M
    Guernane, R
    Mereu, P
    Musso, A
    Oppedisano, C
    Piccotti, A
    Poggio, F
    Scomparin, E
    Sigaudo, F
    Travaglia, G
    Vercellin, E
    Yermia, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (1-2): : 112 - 115
  • [7] STUDY OF THE CHARACTERISTICS OF SINGLE AND DOUBLE GAP RESISTIVE PLATE CHAMBERS FOR A MUON TRIGGER AT LHC
    PONTECORVO, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (01): : 105 - 109
  • [8] Performance of the Resistive Plate Chambers as LVL1 ATLAS muon trigger detectors
    Bianco, M.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 426 - 430
  • [9] The MAD, a full custom ASIC for the CMS barrel muon chambers front end electronics
    Gonella, F
    Pegoraro, M
    PROCEEDINGS OF THE SEVENTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2001, 2001 (05): : 204 - 208
  • [10] Characterization of tetrafluoropropene-based gas mixtures for the Resistive Plate Chambers of the ALICE muon spectrometer
    Bianchi, A.
    Delsanto, S.
    Dupieux, P.
    Ferretti, A.
    Gagliardi, M.
    Joly, B.
    Manen, S. P.
    Marchisone, M.
    Micheletti, L.
    Rosano, A.
    Vercellin, E.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (11)