Sensor Application Using Longitudinal Mode of Screen-Printed PZT Cantilever

被引:8
|
作者
Castille, C. [1 ]
Dufour, I. [1 ]
Maglione, M. [2 ]
Debeda, H. [1 ]
Pellet, C. [1 ]
Lucat, C. [1 ]
机构
[1] Univ Bordeaux, CNRS, UMR 5218, Lab IMS, F-33405 Talence, France
[2] Univ Bordeaux, ICMCB, CNRS, F-33608 Pessac, France
来源
关键词
Cantilever; Gas Detection; Self-Actuated piezoelectric; Thick-film; MICROCANTILEVERS; LAYER;
D O I
10.1016/j.proche.2009.07.242
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
High gas sensitivity, expected when using the unusual longitudinal vibration mode of PZT cantilever for such application, is based on its higher resonant frequency when compared to transversal bending mode. For this purpose, a new PZT cantilever structure has been fabricated with thick-film technology based on the sacrificial layer method. This structure is well adapted to generate the 31's longitudinal vibration. Studies of the composition and microstructure of Au/PZT/Au beam show the harmlessness of the process. Advantage of the 31's longitudinal mode for gas detection is confirmed by the values of resonant frequency and good quality factor for a 8x2x0.08 mm(3) PZT based cantilever. Indeed, taking a 0.1Hz frequency resolution for the second 31 mode, the limit of detection of 6 ppm toluene is reached with a 44 mu m PEUT coating.
引用
收藏
页码:971 / +
页数:2
相关论文
共 50 条
  • [21] Lead Sensor Using Gold Nanostructured Screen-Printed Carbon Electrodes as Transducers
    Martinez-Paredes, Graciela
    Begona Gonzalez-Garcia, Maria
    Costa-Garcia, Agustin
    ELECTROANALYSIS, 2009, 21 (08) : 925 - 930
  • [22] Screen printed PZT/PZT thick film bimorph MEMS cantilever device for vibration energy harvesting
    Xu, R.
    Lei, A.
    Dahl-Petersen, C.
    Hansen, K.
    Guizzetti, M.
    Birkelund, K.
    Thomsen, E. V.
    Hansen, O.
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 188 : 383 - 388
  • [23] Application of screen-printed electrodes as transducers in affinity flow-through sensor systems
    Romero, JMF
    Stiene, M
    Kast, R
    de Castro, MDL
    Bilitewski, U
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (10): : 1107 - 1115
  • [24] Structural and functional properties of screen-printed PZT-PVDF-TrFE composites
    Dietze, Matthias
    Es-Souni, Mohammed
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) : 329 - 334
  • [25] Performance comparison of screen-printed piezoelectric structures on porous PZT and alumina substrates
    Marechal, P.
    Kuscer, D.
    Levassort, F.
    Tran-Huu-Hue, L. P.
    Holc, J.
    Kosec, M.
    Lethiecq, A.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1464 - +
  • [26] Electrochemiluminescence Biosensors Using Screen-Printed Electrodes
    Martinez-Perinan, Emiliano
    Gutierrez-Sanchez, Cristina
    Garcia-Mendiola, Tania
    Lorenzo, Encarnacion
    BIOSENSORS-BASEL, 2020, 10 (09):
  • [27] APPLICATION OF SCREEN-PRINTED ELECTRODES IN BIOCHEMICAL-ANALYSIS
    SCHMIDT, A
    ROHM, I
    RUGER, P
    WEISE, W
    BILITEWSKI, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (8-9): : 607 - 612
  • [28] Dust accumulation sensing system with a screen-printed interdigitated sensor
    Vilmi, Pauliina
    Schuss, Christian
    Hannila, Esa
    Sliz, Rafal
    Fabritius, Tapio
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [29] Screen-printed gold thick films for electrochemical sensor applications
    Rabbow, T. J.
    Junker, N.
    Schneider, M.
    Michaelis, A.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2011, 42 (09) : 777 - 783
  • [30] Screen-printed transcutaneous oxygen sensor employing polymer electrolytes
    Y. Z. Lam
    J. K. Atkinson
    Medical and Biological Engineering and Computing, 2003, 41 : 456 - 463