A study on seismic retrofitting method with siding board for existing timber buildings

被引:0
|
作者
Kohara, K. [1 ]
Takahashi, A. [2 ]
Fukumoto, M. [2 ]
Komoto, K. [3 ]
Imanishi, A. [3 ]
Hagiwara, S. [4 ]
Miyazawa, K. [5 ]
机构
[1] Gifu Acad Forest Sci & Culture, Gifu, Japan
[2] MOK Struct Design Unit Inc, Gifu, Japan
[3] Nonproflt Org WOOD AC, Gifu, Japan
[4] HK Off Inc, Chiba, Japan
[5] Kogakuin Univ, Tokyo, Japan
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It aims to mention about the various examinations to use an exterior siding material as a retrofitting method of construction of the existent buildings. The retrofitting methods of construction of three cases are proposed. In the Case I method, the siding is changed of the existent wall of the range (about 2.0 m) that a part reaches ground floor. In this case, a foothold cost can be reduced. In the Case 2 method, a thickness siding is raised even on the beam. In this case, it works for the improvement in the seismic performance and the fireproof performance. Because a proof stress element and finishing can be included, a restructuring cost can be reduced. The static loading test is enforced all 32 specimens. And several seismic retrofitting plans are explained as case studies. This seismic retrofitting method is effectiveness.
引用
收藏
页码:331 / +
页数:2
相关论文
共 50 条
  • [21] Seismic vulnerability reduction of existing masonry buildings. Modelling of retrofitting techniques
    Gesualdo, Antonio
    Monaco, Michela
    COST ACTION C26: URBAN HABITAT CONSTRUCTIONS UNDER CATASTROPHIC EVENTS, 2010, : 853 - 858
  • [22] Hybrid strategy for the seismic retrofitting of existing buildings through Base Isolation System
    Giuseppe, Brandonisio
    Guidi, Laura Giovanna
    Camarda, Guido
    Sorrentino, Paola
    De Luca, Antonello
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 1292 - 1299
  • [23] Integrated seismic and energy retrofitting of existing buildings: A state-of-the-art review
    Pohoryles, D. A.
    Bournas, D. A.
    Da Porto, F.
    Caprino, A.
    Santarsiero, G.
    Triantafillou, T.
    JOURNAL OF BUILDING ENGINEERING, 2022, 61
  • [25] Seismic resistance of existing buildings with added light timber structure storeys
    Jancar, Jurij
    Zafirov, Trajce
    Premrov, Miroslav
    Dujic, Bruno
    Hristovski, Viktor
    GRADEVINAR, 2022, 74 (05): : 403 - 417
  • [26] Seismic Strengthening of Existing Concrete and Masonry Buildings with Crosslam Timber Panels
    Sustersic, I.
    Dujic, B.
    MATERIALS AND JOINTS IN TIMBER STRUCTURES: RECENT DEVELOPMENTS OF TECHNOLOGY, 2014, 9 : 713 - 723
  • [27] Analysis for seismic retrofitting of buildings
    Jain, Sudhir K.
    Srikant, T.
    Indian Concrete Journal, 2002, 76 (8 SPEC.): : 479 - 484
  • [28] Seismic retrofitting of timber framed walls
    Goncalves, A. M.
    Gomes-Ferreira, J.
    Guerreiro, L.
    Branco, F.
    MATERIALES DE CONSTRUCCION, 2014, 64 (316)
  • [29] Seismic risk of existing buildings: A multidisciplinary method
    Malchoul, Nisrine B.
    Munier, Bertrand
    PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 1503 - 1506
  • [30] A generalized method for seismic evaluation of existing buildings
    Rai, Durgesh C.
    CURRENT SCIENCE, 2008, 94 (03): : 363 - 370