Development of a hard X-ray split-and-delay line and performance simulations for two-color pump-probe experiments at the European XFEL

被引:48
|
作者
Lu, W. [1 ]
Friedrich, B. [2 ]
Noll, T. [2 ]
Zhou, K. [3 ,4 ]
Hallmann, J. [1 ]
Ansaldi, G. [1 ]
Roth, T. [5 ]
Serkez, S. [1 ]
Geloni, G. [1 ]
Madsen, A. [1 ]
Eisebitt, S. [2 ,6 ]
机构
[1] European Xray Free Electron Laser Facil, Holzkoppel 4, D-22869 Schenefeld, Germany
[2] Max Born Inst, Max Born Str 2A, D-12489 Berlin, Germany
[3] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] ESRF European Synchrotron, 71 Ave Martyrs, F-38000 Grenoble, France
[6] Tech Univ Berlin, Inst Opt & Atomare Phys, D-10623 Berlin, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 06期
关键词
FREE-ELECTRON LASERS; PHOTON-CORRELATION SPECTROSCOPY; PULSES; FEL; GENERATION; BANDWIDTH; SCHEME;
D O I
10.1063/1.5027071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A hard X-ray Split-and-Delay Line (SDL) under construction for the Materials Imaging and Dynamics station at the European X-Ray Free-Electron Laser (XI-EL) is presented. This device aims at providing pairs of X-ray pulses with a variable time delay ranging from -10 ps to 800 ps in a photon energy range from 5 to 10 keV for photon correlation and X-ray pump-probe experiments. A custom designed mechanical motion system including active feedback control ensures that the high demands for stability and accuracy can be met and the design goals achieved. Using special radiation configurations of the European XI-EL's SASE-2 undulator (SASE: Self-Amplified Spontaneous Emission), two-color hard x-ray pump-probe schemes with varying photon energy separations have been proposed. Simulations indicate that more than 10(9) photons on the sample per pulse-pair and up to about 10% photon energy separation can be achieved in the hard X-ray region using the SDL. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 22 条
  • [21] Probing the non-equilibrium transient state in magnetite by a jitter-free two-color X-ray pump and X-ray probe experiment
    Pontius, N.
    Beye, M.
    Trabant, C.
    Mitzner, R.
    Sorgenfrei, F.
    Kachel, T.
    Woestmann, M.
    Roling, S.
    Zacharias, H.
    Ivanov, R.
    Treusch, R.
    Buchholz, M.
    Metcalf, P.
    Schuessler-Langeheine, C.
    Foehlisch, A.
    STRUCTURAL DYNAMICS-US, 2018, 5 (05):
  • [22] Development of a compact fast CCD camera and resonant soft x-ray scattering endstation for time-resolved pump-probe experiments
    Doering, D.
    Chuang, Y. -D.
    Andresen, N.
    Chow, K.
    Contarato, D.
    Cummings, C.
    Domning, E.
    Joseph, J.
    Pepper, J. S.
    Smith, B.
    Zizka, G.
    Ford, C.
    Lee, W. S.
    Weaver, M.
    Patthey, L.
    Weizeorick, J.
    Hussain, Z.
    Denes, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (07):