Diode dosimetry for the routine quality assurance in IMRT

被引:0
|
作者
Xu, Z.
Yang, G.
Li, W.
机构
[1] SUNY Stony Brook, Stony Brook, NY 11794 USA
[2] Mem Sloan Kettering Canc Ctr, Commack, NY USA
[3] Long Isl Jewish Med Ctr, Queens Hosp Ctr, Jamaica, NY 11432 USA
关键词
D O I
10.1118/1.2760817
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Due to the complexity of IMRT dosimetry, dose evaluation is usually done using a QA phantom for MU and isodose line measurement. However, the actual treatment fields to be delivered to the patients are not usually evaluated. This is because with Varis one has to implement a work‐around to perform IMRT QA, i.e., separately sending the entire data set to a separate “QA course” in which case one never really QAs what the patient is being treated but instead a copy of the patient data. In this case, errors could occur in the original data transfer that would not be picked up in the QA exercise. Method and Materials: IMRT planning was done using Eclipse and exported to VARIS. A Varian 21EX Linac was used for IMRT treatment. VeriDose diode detector was used for in vivo measurement. A MapCheck, Ion chamber and a solid water were used for MU and isodose line check. Our diode reference readings were obtained at the time of IMRT QA and measured on the phantom on the CAX at the corresponding patient's SSD with the same fields as for “QA course”. Results: For prostate IMRT treatments, the ratios of the measured diode dose on phantom to dose on patient are all within ±5%, but individual field measurements exhibit excursions of up to ±8%. The difference is greater for Breast and H&N IMRT with the maximum discrepancy of about ±8% % and ±10%, respectively. Conclusions: We have evaluated the use of diodes for application to IMRT in vivo dosimetry. Phantom and patient measurements are compared to be in agreement to generally better than 10%. We believe that in vivo diode dosimetry adds a necessary component to IMRT QA by allowing us to make the link between the detailed phantom measurements with the actual treatment situation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2437 / 2437
页数:1
相关论文
共 50 条
  • [21] THE STATISTICAL ANALYSIS OF PATIENT SPECIFIC DOSIMETRY QUALITY ASSURANCE (DQA) OF IMRT PLANS
    Chung, J. B.
    Kim, J. S.
    Kim, I. A.
    Park, J. M.
    Park, Y. G.
    Kim, H. J.
    Wu, H. G.
    Kim, I. H.
    Chie, E. K.
    Suh, T. S.
    Ye, S. J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S394 - S394
  • [22] Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance
    Narayanasamy, Ganesh
    Zalman, Travis
    Ha, Chul S.
    Papanikolaou, Niko
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 329 - 338
  • [23] The statistical analysis of patient specific dosimetry quality assurance (DQA) of IMRT plans
    Kim, J.
    Chung, J.
    Kim, I.
    Kim, I.
    Ye, S.
    Suh, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S670 - S670
  • [24] Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline
    Chung, Jin Beom
    Kim, Jae Sung
    Ha, Sung Whan
    Ye, Sung-Joon
    RADIATION ONCOLOGY, 2011, 6
  • [25] Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline
    Jin Beom Chung
    Jae Sung Kim
    Sung Whan Ha
    Sung-Joon Ye
    Radiation Oncology, 6
  • [26] Quality assurance of IMRT
    Chui, CS
    LoSasso, T
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 168 - 169
  • [27] EPID dosimetry must soon become an essential component of IMRT quality assurance
    van Elmpt, Wouter
    Ezzell, Gary A.
    Orton, Colin G.
    MEDICAL PHYSICS, 2009, 36 (10) : 4325 - 4327
  • [28] Response to "Comment on 'In vivo dosimetry for routine quality assurance in IMRT"' -: [Med. Phys. 31, 1642-1643 (2004)]
    Higgins, PD
    Alaei, P
    Gerbi, BJ
    Dusenbery, KE
    MEDICAL PHYSICS, 2004, 31 (06) : 1644 - 1644
  • [29] Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer
    Wertz, Hansjoerg
    Boda-Heggemann, Judit
    Walter, Cornelia
    Dobler, Barbara
    Mai, Sabine
    Wenz, Frederik
    Lohr, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (01): : 288 - 295
  • [30] Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry
    Silveira, M. A.
    Pavoni, J. F.
    Baffa, O.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 1 - 6