Forensic Analysis of a Contact Lens in a Murder Case

被引:3
|
作者
Zwerling, Charles S. [1 ]
机构
[1] Goldsboro Eye Clin, 2709 Med Off Pl, Goldsboro, NC 27534 USA
关键词
forensic science; forensic ophthalmology; forensic contact lenses; forensic murder exhumation; abaroa murder; forensic simulated burial; forensic inversion marks; HYDROGEL LENSES;
D O I
10.1111/1556-4029.13021
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations.
引用
收藏
页码:534 / 539
页数:6
相关论文
共 50 条
  • [41] Effect of a Warming Device on Contact Lens Case Contamination
    Willcox, Mark D. P.
    Zhu, Hua
    Vijay, Ajay K.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (06): : 394 - 399
  • [42] CASE REPORT - UNDERWATER CONTACT-LENS CORRECTION
    HURLOCK, R
    MALIN, AH
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (08): : 653 - 655
  • [43] A Case of Contact Lens Induced Acute Red Eye
    Lee, Jun Young
    Kim, Hui Kyung
    Jo, Yeon Ji
    Lee, Jong Soo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (04): : 350 - 354
  • [44] Case of bilateral Wessely rings in a contact lens wearer
    Qiao, Grace L.
    O'Donnell, Heather
    Yeung, Sonia N.
    Iovieno, Alfonso
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2019, 54 (04): : E182 - E183
  • [45] Bringing Sustainability Into Focus: The Case for Contact Lens Recycling
    Bhatnagar, Priyanka
    Devireddy, Nitya
    Tharp, Margaret
    Chen, Stephanie P.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (12): : 527 - 528
  • [46] Contact Lens Storage Case Hygiene Practice and Storage Case Contamination
    Vijay, Ajay Kumar
    Willcox, Mark
    Zhu, Hua
    Stapleton, Fiona
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (02): : 91 - 97
  • [47] Isolation of Staphylococcus aureus from a contact lens at the time of a contact lens-induced peripheral ulcer:: Case report
    Jalbert, I
    Willcox, MDP
    Sweeney, DF
    CORNEA, 2000, 19 (01) : 116 - 120
  • [48] Basics of Practical Contact Lens Fitting (Part 2: Practical Process of Contact Lens Fitting, Troubleshooting and Case Reports)
    von Livonius, Bettina
    Emminger, Ralf
    Ring-Mangold, Theresia
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2021, 238 (04) : 523 - 537
  • [49] Myopia progression before and after fitting with the NaturalVue multifocal contact lens - a case series analysis
    Aller, Thomas A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [50] Effect of Water Exposure on Contact Lens Storage Case Contamination in Soft Lens Wearers
    Arshad, Memoona
    Carnt, Nicole
    Tan, Jacqueline
    Stapleton, Fiona
    OPTOMETRY AND VISION SCIENCE, 2021, 98 (09) : 1002 - 1010