A Three-Dimensional Resonant Triggering Probe for Micro-CMM

被引:16
|
作者
Huang, Qiangxian [1 ]
Chen, Chen [1 ]
Wu, Kui [1 ]
Zhang, Liansheng [1 ]
Li, Ruijun [1 ]
Fan, Kuang-Chao [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Instrument Sci & Optoelect Engn, 193 Tunxi Rd, Hefei 230009, Peoples R China
[2] Natl Taiwan Univ, Dept Mech Engn, 1,Sect 4,Roosevelt Rd, Taipei 10617, Taiwan
来源
APPLIED SCIENCES-BASEL | 2017年 / 7卷 / 04期
基金
中国国家自然科学基金;
关键词
3D resonant trigger probe; quartz tuning fork; interfacial force; resonant vibration; micro/nano CMM; 3D profile measurement; FORCE MICROSCOPY; SCANNING PROBE; SYSTEM; MODE; SILICON; SENSOR;
D O I
10.3390/app7040403
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
To achieve true 3D nano-measurement with sub-nanometer resolution and very low touch force through a micro/nano coordinate measuring machine, a new 3D resonant trigger probe based on a quartz tuning fork is proposed. In this trigger probe, a quartz tuning fork with a microsphere tip vibrates at its resonant frequency, and is used as the sensing element. The resonance parameters of this quartz tuning fork (e.g., vibrating amplitude and resonant frequency) are extremely sensitive to external 3D microforces. The distinguished feature of this probe is its ability to interact with the sample surface in the actual three directions. The microsphere tip of the probe interacts with the sample surface in tapping mode in the Z direction, whereas it interacts in friction mode in the X and Y directions. The dynamic contact mechanism of the probe is based on interfacial force theory, and mechanical models of the interactions between the microsphere tip and sample surface in the X, Y, and Z directions are constructed and simulated. The experiment shows that the probe has sub-nanometer resolution in 3D directions and triggers repeatability of approximately 40 nm in each direction. Theoretical analysis and experimental results verify that this 3D resonant trigger probe can be used for true 3D profile measurement.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Resonant motions of the three-dimensional elastic pendulum
    Lynch, P
    INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2002, 37 (02) : 345 - 367
  • [32] Mie-Resonant Three-Dimensional Metacrystals
    Kim, Seokhyoung
    Zheng, Cindy Y.
    Schatz, George C.
    Aydin, Koray
    Kim, Kyoung-Ho
    Mirkin, Chad A.
    NANO LETTERS, 2020, 20 (11) : 8096 - 8101
  • [33] Three-dimensional simulation of micro pumps
    Xu, Y
    Kong, YP
    Zhang, XX
    Yao, K
    Choong, WO
    Tay, FEH
    Wang, WP
    MICROFLUIDICS AND BIOMEMS, 2001, 4560 : 61 - 66
  • [34] Three-dimensional layout in micro factories
    Scholz-Reiter, Bernd
    Brenner, Nele
    Lütjen, Michael
    Keck, Martin
    ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, 2009, 104 (09): : 791 - 795
  • [35] Three-dimensional fiber probe based on orthogonal micro focal-length collimation for the measurement of micro parts
    Cui, Jiwen
    Li, Junying
    Feng, Kunpeng
    Tan, Jiubin
    OPTICS EXPRESS, 2015, 23 (20): : 26386 - 26398
  • [36] On a Generalized Noncommutative Three-Dimensional Three Wave Resonant Equation
    Li, Chun-Xia
    Nimmo, Jonathan J. C.
    Wang, Hong-Yan
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2022, 91 (10)
  • [37] Interface analysis with the three-dimensional atom probe
    Miller, MK
    SURFACE AND INTERFACE ANALYSIS, 2001, 31 (07) : 593 - 598
  • [38] Performance of the IMR three-dimensional atom probe
    Hono, K.
    Okano, R.
    Saeda, T.
    Sakurai, T.
    Applied Surface Science, 1995, 87-88 (1-4): : 453 - 459
  • [39] Ultrasonic probe for detecting a three-dimensional vibration
    Mizutani, K
    Wakatsuki, N
    Nagai, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B): : 3160 - 3161
  • [40] A new design for a three-dimensional measurement probe
    Sohn, A
    Dow, TA
    Marino, EA
    PROCEEDINGS OF THE FIFTEENTH ANNUAL MEETING OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 2000, : 537 - 541