A reconstruction concept for ECG-gated multi-slice spiral CT cf the heart with pulse-rate adaptive optimization of spatial and temporal resolution

被引:0
|
作者
Flohr, TG
Ohnesorge, BM
Becker, CD
Kopp, AF
Halliburton, SS
Knez, A
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
974
引用
收藏
页码:438 / 438
页数:1
相关论文
共 27 条
  • [21] Evaluation of coronary arterial stenosis rate using simulated coronary arterial stenosis phantoms with retrospective ECG-gated reconstruction employing multi-slice (4-row) CT
    Taniguchi, A
    Jinzaki, M
    Kuribayashi, S
    Watanabe, N
    Kataoka, T
    Nobuta, Y
    RADIOLOGY, 2002, 225 : 193 - 193
  • [22] Cardiac multidetector-row CT:: Retrospectively ECG-gated spiral with optimized temporal and spatial resolution:: First clinical results.
    Kopp, AF
    Ohnesorge, B
    Flohr, T
    Georg, C
    Schröder, S
    Küttner, A
    Martensen, J
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (05): : 429 - 435
  • [23] Coronary artery visualization by multi-slice spiral CT: Influence of heart rate on the position of the optimal data reconstruction window
    Giesler, T
    Mennicke, M
    Wenkel, E
    Pohle, K
    Ulzheimer, S
    Bautz, W
    Kalender, WA
    Baum, U
    CIRCULATION, 2002, 106 (19) : 516 - 516
  • [24] Efficacy of the ECG-gated reconstruction technique in 3D-CTA using multi-slice helical CT for the preoperative assessment of the ascending aorta in patients with aortic diseases
    Kobayashi, Y
    Tanaka, O
    Imai, N
    Adachi, H
    Hiraoka, M
    Taguchi, K
    RADIOLOGY, 2000, 217 : 134 - 135
  • [25] Influence of tube voltage and heart rate on the Agatston calcium score using an in vitro, novel ECG-gated dual energy reconstruction 320 slice CT technique
    Funabashi, Nobusada
    Irie, Ryosuke
    Namihira, Yasuaki
    Morimoto, Ryo
    Aiba, Miki
    Ozawa, Koya
    Takaoka, Hiroyuki
    Ohta, Joji
    Masuda, Yoshitada
    Kobayashi, Yoshio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 180 : 218 - 220
  • [26] ECG-gated spiral scanning of the lung and mediastinal vessels with optimized temporal resolution and cone-correction on a 16-slice CT-system: Performance evaluation and initial clinical results
    Flohr, TG
    Bruder, HK
    Kuettner, A
    Heuschmid, M
    Schaller, S
    Ohnesorge, BM
    RADIOLOGY, 2002, 225 : 449 - 450
  • [27] Analysis of heart rate and its variation affecting image quality and optimized reconstruction window in retrospective ECG-gated coronary angiography using multi-detector row CT
    Lee, SH
    Choi, BW
    Kim, HJ
    Jung, H
    Son, HK
    Kang, WS
    Yoo, SK
    Choe, KO
    Yoo, HS
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1622 - 1626