Trabecular Metal Augments for Severe Acetabular Defects in Revision Hip Arthroplasty: A Long-Term Follow-Up

被引:22
|
作者
Russell, Shane P. [1 ,2 ]
O'Neill, Cathleen J. [1 ,2 ]
Fahey, Eoin J. [1 ,2 ]
Guerin, Shane [1 ,3 ]
Gul, Rehan [1 ,3 ]
Harty, James A. [1 ,3 ]
机构
[1] Victoria Univ Hosp, Dept Trauma & Orthopaed, South Infirm, Cork, Ireland
[2] Royal Coll Surgeons Ireland, Dublin, Ireland
[3] Univ Coll Cork, Cork, Ireland
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 05期
关键词
trabecular metal augments; revision hip arthroplasty; acetabular defects; hip center of rotation; osseointegration; osteolysis; BONE LOSS; COMPONENT; SELECTION;
D O I
10.1016/j.arth.2020.12.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Paprosky type IIIa and IIIb acetabular defects remain technically challenging during revision hip arthroplasty. Numerous surgical options exist to counter extensive acetabular bone loss with high postoperative complication and revision rates reported. Our aim was to report comprehensive long-term outcomes of our experience with Trabecular Metal (TM) augments for these difficult cases. Methods: 38 patients underwent revision total hip arthroplasty at our institution from 2009 to 2014 where a TM augment was used for acetabular deficiency. Prospective radiographic and Patient-Reported Outcome Measures were recorded and analyzed to a mean of 7.3 years (range: 5.4 to 10.8). Results: No patient was excluded or lost to follow-up. Complications included 3 intraoperative fractures, 1 early infection requiring washout with implant retention, 1 early revision due to allograft resorption, and 6 patients who required late repeat revision surgery: 3 for late infection, 2 for aseptic loosening with augment fracture or dislocation, and 1 for recurrent dislocation. The estimated mean implant survivorship was 8.99 years. 93.5% of augments remaining were well osseointegrated while 97% of the acetabular shells were osseointegrated. Hip center of rotation was restored by a mean of 14 mm inferiorly without significant medialization. Short Form-12 (SF-12) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were significantly reduced postoperatively to a level comparable to the average individual. Conclusion: This long-term study details our experience of TM augments for the most severe acetabular defects. For such cases, no excellent surgical solution exists; in comparison to alternative methods, we advocate that this technique is reasonably safe and effective. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1740 / 1745
页数:6
相关论文
共 50 条
  • [21] Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study
    Huang, De-Yong
    Zhang, Liang
    Zhou, Yi-Xin
    Zhang, Chun-Yu
    Xu, Hui
    Huang, Yong
    CHINESE MEDICAL JOURNAL, 2016, 129 (08) : 903 - 908
  • [22] Mid-Term Outcomes of Revision Hip Arthroplasty with Acetabular Augments
    Korytkin, A. A.
    Novikova, Ya S.
    Kovaldov, K. A.
    Korolev, S. B.
    Zykin, A. A.
    Gerasimov, S. A.
    Gerasimov, E. A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2019, 25 (01): : 9 - 18
  • [23] Treatment of Severe Acetabular Defects With an Antiprotrusio Cage and Trabecular Metal Augments - Clinical and Radiographic Results After a Mean Follow-Up of 6.6 Years
    Bellova, Petri
    Reich, Marie-Christin
    Grothe, Tim
    Guenther, Klaus-Peter
    Stiehler, Maik
    Goronzy, Jens
    JOURNAL OF ARTHROPLASTY, 2023, 38 (11): : 2415 - 2422
  • [24] Revision hip arthroplasty using impacted cancellous bone and cement: a long-term follow-up study
    Arumugam G.
    Nanjayan S.K.
    Quah C.
    Wraighte P.
    Howard P.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1279 - 1284
  • [25] Acetabular Revision Using Trabecular Metal Augments for Paprosky Type 3 Defects
    O'Neill, Cathleen J.
    Creedon, Stephen B.
    Brennan, Stephen A.
    O'Mahony, Fiona J.
    Lynham, Rosanne S.
    Guerin, Shane
    Gul, Rehan
    Harty, James A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 823 - 828
  • [26] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Mitchell Bernstein
    Nicholas M. Desy
    Alain Petit
    David J. Zukor
    Olga L. Huk
    John Antoniou
    International Orthopaedics, 2012, 36 : 1807 - 1812
  • [27] Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty
    Bernstein, Mitchell
    Desy, Nicholas M.
    Petit, Alain
    Zukor, David J.
    Huk, Olga L.
    Antoniou, John
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1807 - 1812
  • [28] Reconstruction of Proximal Metaphyseal Femoral Defects Using Trabecular Metal Augments in Revision Total Hip Arthroplasty
    Simon, Sebastian
    Frank, Bernhard J. H.
    Aichmair, Alexander
    Dominkus, Martin
    Hofstaetter, Jochen G.
    ARTHROPLASTY TODAY, 2021, 8 : 216 - 221
  • [29] Phosphocalcium ceramics are efficient in the management of severe acetabular loss in revision hip arthroplasties. A 22 cases long-term follow-up study
    Schwartz C.
    Vautrin M.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (2) : 227 - 232
  • [30] Titanium cage reconstruction of acetabular defects in revision hip arthroplasty results in favourable outcomes: up to 17 years follow-up
    Akel, Ibrahim
    Caglar, Omur
    Tokgozoglu, A. Mazhar
    Atilla, Bulent
    HIP INTERNATIONAL, 2020, 30 (05) : 617 - 621