Experimental study on distributed optical-fiber cable for high-pressure buried natural gas pipeline leakage monitoring

被引:34
|
作者
Zhou, Zhaoming [1 ]
Zhang, Jia [1 ]
Huang, Xuesong [2 ]
Guo, Xishui [2 ]
机构
[1] Southwest Petr Univ, Sch Mechatron Engn, Xindu Ave 8, Chengdu 610500, Sichuan, Peoples R China
[2] Petr Engn Technol Res Inst Sinopec Zhongyuan Oilf, Puyang 457000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical cable; Natural gas pipeline; Leak detection; Raman optical time domain reflect (ROTDR); Numerical analysis; SENSOR; OIL;
D O I
10.1016/j.yofte.2019.102028
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At present, fiber-optic cable monitoring technology uses an fiber-optic cable located at 300 mm above a buried natural gas pipeline to collect gas leakage information. However, the change in soil temperature caused by natural gas leakage is not tested and verified. This prevents the installment of an fiber-optic cable for monitoring gas leakage in the field. To improve the sensitivity of fiber-optic cable leakage monitoring and reduce the failure rate, the laying mode of fiber-optic cable should be verified and analyzed. In this study, Peng-Robinson (PR) real gas state equation, a Raman optical time-domain reflectometer (ROTDR), and finite element method (FEM) were combined to simulate the gas leakage of buried pipelines. The trend of soil temperature around the leak hole and laying mode of fiber-optic cable was studied. It can be concluded that the higher the pressure of pipeline and leakage hole, the greater the temperature change at 100 mm directly above the pipeline. On this basis, a field test was carried out to study the leakage of a buried high-pressure natural gas pipeline. The experimental results show that the gas leakage can be detected by an fiber-optic cable located at 100 mm above the pipeline, and it is difficult to detect the change in soil temperature when the fiber-optic cable is located 200 mm or farther. The experimental results are consistent with the simulation results. This indicates that the simulation method is correct and feasible. Thus, the fiber-optic cable needs to be placed 100 mm or closer to the buried pipeline to monitor the temperature change. The result of the test and the simulation result are coincident approximately. The conclusion is: evenly lay 4 optical cables within 100 mm around the pipe, and each cable can monitor the temperature change in the 90 degrees range above the leakage hole. This method can accurately monitor the leakage of the whole pipe section. The study results can guide the laying plan of fiber-optic cables and construction of natural gas pipelines and prevent accidents.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Monitoring of soil temperature field due to leakage of buried thermal pipeline using distributed fiber optic sensor
    Chen S.
    Li S.
    Huang D.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (03): : 138 - 145
  • [22] Study on oil and gas pipeline leakage real-time inspection system based on distributed optical fiber
    Zhou, J.Y.
    Jin, S.J.
    Feng, H.
    Zeng, Z.M.
    Qu, Z.G.
    Key Engineering Materials, 2008, 381-382 : 447 - 450
  • [23] Feature extraction and identification in distributed optical-fiber vibration sensing system for oil pipeline safety monitoring
    Huijuan Wu
    Ya Qian
    Wei Zhang
    Chenghao Tang
    Photonic Sensors, 2017, 7 : 305 - 310
  • [24] Feature Extraction and Identification in Distributed Optical-Fiber Vibration Sensing System for Oil Pipeline Safety Monitoring
    Wu, Huijuan
    Qian, Ya
    Zhang, Wei
    Tang, Chenghao
    PHOTONIC SENSORS, 2017, 7 (04) : 305 - 310
  • [25] A new real-gas model to characterize and predict gas leakage for high-pressure gas pipeline
    Yuan, Fang
    Zeng, Yan
    Khoo, Boo Cheong
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2022, 74
  • [26] Risk assessment for a high-pressure natural gas pipeline in an urban area
    Jo, YD
    Park, KS
    Ahn, BJ
    SUSTAINABLE CITY III: URBAN REGENERATION AND SUSTAINABILITY, 2004, 18 : 541 - 547
  • [27] Response of a high-pressure natural gas pipeline to coal nune blasts
    Aimone-Martin, C
    Clah, E
    PROCEEDINGS OF THE TWENTY-NINTH ANNUAL CONFERENCE ON EXPLOSIVES AND BLASTING TECHNIQUE, VOL 2, 2003, : 213 - 222
  • [28] Application of distributed optical fiber sensing technologies to the monitoring of leakage and abnormal disturbance of oil pipeline
    Yang Xiaojun
    Zhu Xiaofei
    Deng Chi
    Li Junyi
    Liu Cheng
    Yu Wenpeng
    Luo Hui
    AOPC 2017: FIBER OPTIC SENSING AND OPTICAL COMMUNICATIONS, 2017, 10464
  • [29] Experimental study of near-field characteristics of high-pressure CO2 pipeline leakage
    Wang, Jiaqiang
    Yan, Liguo
    Xiao, Chenhuan
    Zhang, Zixuan
    Liu, Dongrun
    Yao, Shujian
    Lu, Zhaijun
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2024, 137
  • [30] Experimental Study of Leakage Monitoring of Diaphragm Walls Based on Distributed Optical Fiber Temperature Measurement Technology
    Liu, Tao
    Sun, Wenjing
    Kou, Hailei
    Yang, Zhongnian
    Meng, Qingsheng
    Zheng, Yuqian
    Wang, Haotong
    Yang, Xiaotong
    SENSORS, 2019, 19 (10):