Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use

被引:1
|
作者
Santoro, Amato [1 ]
Baiocchi, Claudia [1 ]
Sisti, Nicolo [1 ]
Zaca, Valerio [1 ]
Pondrelli, Carlo Renato [2 ]
Falciani, Francesca [3 ]
Lamberti, Filippo [4 ]
机构
[1] Azienda Osped Univ Senese, Div Cardiol, Siena, Italy
[2] Azienda Osped Univ Senese, Div Med, Siena, Italy
[3] Misericordia Hosp, Dept Cardiol, Grosseto, Italy
[4] San Eugenio Hosp, Div Med, Cardiovasc Sect, Rome, Italy
关键词
atrial flutter ablation; zero fluoroscopy catheter ablation; ATRIAL-FLUTTER; RADIOFREQUENCY ABLATION; TRICUSPID-VALVE; ANATOMY; ARRHYTHMIAS;
D O I
10.1002/joa3.12596
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Catheter ablation (CA) is the choice therapy of cavotricuspid isthmus (CTI) atrial flutter. The aim of this study was to describe our approach to improve the CTI ablation using a zero-fluoroscopy (ZF). The procedural difficulties could be related to anatomical characteristics of the CTI. Methods: One hundred eighty-eight patients that performed CA of CTI were retrospectively and consecutively evaluated between 2017 and 2019. The studied population was divided into two groups. Eighty-eight patients who were undergone CA using ablation catheter without shaft visualization catheter (NSV) were Group 1. One hundred patients were undergone CA using ablation catheter with a shaft visualization (SV); they were Group 2. The catheter was looped at the Eustachian ridge after 200 seconds of radiofrequencies (RF) without elimination of local electrogram. Results: A conduction line block of CTI was obtained in all patients of Group 2 using a ZF approach. In 16 patients of Group 1, the catheter inversion was obtained using fluoroscopy to avoid damages during its loop. In Group 2, a complete CTI block was obtained with a catheter inversion approach in ten patients without fluoroscopy, visualizing the shaft and the tip of the ablation catheter on the electroanatomic (EAM) map. In the overall population studied the use of SV had a linear correlation with the ZF approach (r = .629; P < .001). The duration of RF was lower in Group 2 than in Group 1 (Group 1: 27.8 +/- 6.3 vs Group 2: 15.6 +/- 7.2 minutes; P < .01). The procedure time between two groups was lower in Group 2 than in Group 1 (Group 1: 58.4 +/- 22.4 vs Group 2: 42.2 +/- 15.7 minutes; P < .01). No differences between two groups were documented regarding success and complications. Conclusions: The visualization of the shaft's catheter on the EAM permitted the catheter inversion safely in order to overcome some complex CTI anatomy and obtain bidirectional block. The SV reduced procedure time, RF applications and fluoroscopy exposition during CTI ablation.
引用
收藏
页码:1311 / 1317
页数:7
相关论文
共 50 条
  • [1] Catheter inversion during cavotricuspid isthmus catheter ablation: the new shaft visualization catheter reduces fluoroscopy use
    Sisti, Nicolo
    Santoro, Amato
    Baiocchi, Claudia
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G)
  • [2] Catheter inversion during cavotricuspid isthmus catheter ablation: the new shaft visualization catheter reduces fluoroscopy use
    Sisti, Nicolo
    Santoro, Amato
    Baiocchi, Claudia
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [3] Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus
    Da Costa, A
    Faure, E
    Thévenin, J
    Messier, M
    Bernard, S
    Abdel, K
    Robin, C
    Romeyer, C
    Isaaz, K
    CIRCULATION, 2004, 110 (09) : 1030 - 1035
  • [4] LEARNING CURVE FOR THE ZERO-FLUOROSCOPY CATHETER ABLATION OF THE CAVOTRICUSPID ISTHMUS
    Alvarez, M.
    Herrera, N.
    Tercedor, L.
    Algarra, M.
    Macias, R.
    Melgares, R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S1 - S1
  • [5] Cavotricuspid Isthmus Catheter Ablation Without the Use of Fluoroscopy as a First-Line Treatment
    Alvarez, Miguel
    Tercedor, Luis
    Herrera, Norberto
    Munoz, Luz
    Galdeano, Ricardo S.
    Valverde, Francisca
    Penas, Rocio
    Melgares, Rafael
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (06) : 656 - 662
  • [6] Is a cooled tip catheter the solution for the ablation of the cavotricuspid isthmus?
    Scavée, C
    Georger, F
    Jamart, J
    Mancini, I
    Collet, B
    Blommaert, D
    De Roy, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 328 - 331
  • [7] Effects of cavotricuspid isthmus catheter ablation on paroxysmal atrial fibrillation
    Kumagai, K
    Tojo, H
    Noguchi, H
    Yasuda, T
    Tamari, H
    Matsumoto, N
    Gondo, N
    Nakashima, H
    Saku, K
    JAPANESE HEART JOURNAL, 2001, 42 (01): : 79 - 89
  • [8] TYPICAL ATRIAL FLUTTER: RADIOFREQUENCY CATHETER ABLATION OF CAVOTRICUSPID ISTHMUS WITH COOLED-TIP CATHETER
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (01): : 21 - 26
  • [9] Predictors of recurrent atrial flutter after catheter ablation of the cavotricuspid isthmus
    Benhalla, H.
    Sorea, C.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 27 - 27
  • [10] Catheter selection for ablation of the cavotricuspid isthmus for treatment of typical atrial flutter
    Antoine Da Costa
    Yann Jamon
    Cécile Romeyer-Bouchard
    Jérôme Thévenin
    Marc Messier
    Karl Isaaz
    Journal of Interventional Cardiac Electrophysiology, 2006, 17 : 93 - 101