Is a cooled tip catheter the solution for the ablation of the cavotricuspid isthmus?

被引:14
|
作者
Scavée, C [1 ]
Georger, F [1 ]
Jamart, J [1 ]
Mancini, I [1 ]
Collet, B [1 ]
Blommaert, D [1 ]
De Roy, L [1 ]
机构
[1] Univ Louvain, UCL Mt Godinne, Yvoir, Belgium
来源
关键词
atrial flutter; catheter ablation; cool tip catheter;
D O I
10.1046/j.1460-9592.2003.00043.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To test the theoretical superiority of irrigated tip catheters to achieve complete cavotricuspid isthmus block, a 4-mm cooled tip catheter was compared to a conventional 8-mm tip catheter with a double temperature sensor in the cavotricuspid isthmus (CTI) ablation. The study prospectively enrolled 60 patients (47 men, mean 65 10 years) with common flutter divided in group 1 (n = 30) assigned to an 8-mm tip catheter versus group 2 (n = 30), assigned to an internal circuit, irrigated tip catheter. Linear radio frequency applications were performed in a point-by-point protocol to achieve complete CTI block. Complete CTI block was achieved in 29 patients in each group. Mean durations of procedure and fluoroscopy were 91 versus 90 and 40 versus 33 minutes in group 1 versus 2, respectively, (NS). The mean number/patient of RFpulses to interrupt atrialflutter was four in group 1 and eight in group 2 (P = 0.034), and 11 and 13, respectively, to interrupt CTI conduction (NS). The total energy delivered was similar in both groups (29,237 vs 23,236 W/s, NS). CTI ablation with a conventional 8-mm tip catheter versus an irrigated tip catheter was associated with similar success rates, procedure duration, and fluoroscopic exposure. The technical complexity of the cooled tip catheter renders it less competitive. (PACE 2003; 26[Pt. II]:328-331).
引用
收藏
页码:328 / 331
页数:4
相关论文
共 50 条
  • [1] TYPICAL ATRIAL FLUTTER: RADIOFREQUENCY CATHETER ABLATION OF CAVOTRICUSPID ISTHMUS WITH COOLED-TIP CATHETER
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (01): : 21 - 26
  • [2] Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus
    Da Costa, A
    Faure, E
    Thévenin, J
    Messier, M
    Bernard, S
    Abdel, K
    Robin, C
    Romeyer, C
    Isaaz, K
    CIRCULATION, 2004, 110 (09) : 1030 - 1035
  • [3] Comparison of the efficacy of cooled-tip and 8-mm-tip catheters for radiofrequency catheter ablation of the cavotricuspid isthmus:: A meta-analysis
    Da Costa, A
    Cucherat, M
    Pichon, N
    Messier, M
    Laporte, S
    Roméyer-Bouchard, C
    Mismetti, P
    Lopez, M
    Isaaz, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (10): : 1081 - 1087
  • [4] Irrigated tip catheters: experimental study on the ablation of the cavotricuspid isthmus
    Rebollo, JG
    Madrid, A
    del Rey, JM
    Alvarez, T
    Correa, C
    Chercoles, AI
    Lobelo, R
    Socas, A
    Pena, G
    Moro, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 445 - 445
  • [5] Effects of cavotricuspid isthmus catheter ablation on paroxysmal atrial fibrillation
    Kumagai, K
    Tojo, H
    Noguchi, H
    Yasuda, T
    Tamari, H
    Matsumoto, N
    Gondo, N
    Nakashima, H
    Saku, K
    JAPANESE HEART JOURNAL, 2001, 42 (01): : 79 - 89
  • [6] Gold-tip versus contact-sensing catheter for cavotricuspid isthmus ablation: A comparative study
    Gul, Enes Elvin
    Boles, Usama
    Haseeb, Sohaib
    Hopman, Wilma M.
    Chacko, Sanoj
    Simpson, Chris
    Abdollah, Hoshiar
    Michael, Kevin
    Baranchuk, Adrian
    Redfearn, Damian
    Glover, Benedict
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (06): : 464 - 470
  • [7] Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study
    Lewalter, Thorsten
    Weiss, Christian
    Spencker, Sebastian
    Jung, Werner
    Haverkamp, Wilhelm
    Willems, Stephan
    Deneke, Thomas
    Kautzner, Josef
    Wiedemann, Michael
    Siebels, Juergen
    Pitschner, Heinz Friedrich
    Hoffmann, Ellen
    Hindricks, Gerd
    Zabel, Markus
    Vester, Ernst
    Schwacke, Harald
    Mittmann-Braun, Erica
    Lickfett, Lars
    Hoffmeister, Sabine
    Proff, Jochen
    Mewis, Christian
    Bauer, Wolfgang
    EUROPACE, 2011, 13 (01): : 102 - 108
  • [8] Randomized Comparison of Cavotricuspid Isthmus Ablation for Atrial Flutter Using an Open Irrigation-Tip versus a Large-Tip Radiofrequency Ablation Catheter
    Ilg, Karl J.
    Kuehne, Michael
    Crawford, Thomas
    Chugh, Aman
    Jongnarangsin, Krit
    Good, Eric
    Pelosi, Frank, Jr.
    Bogun, Frank
    Morady, Fred
    Oral, Hakan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (09) : 1007 - 1012
  • [9] Predictors of recurrent atrial flutter after catheter ablation of the cavotricuspid isthmus
    Benhalla, H.
    Sorea, C.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 27 - 27
  • [10] Cavotricuspid isthmus catheter ablation across an inferior vena cava filter
    Haman, L
    Parizek, P
    Maly, R
    Vojacek, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (03): : 331 - 333