Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography

被引:0
|
作者
Zhang, X. [1 ]
Tilley, S. [1 ]
Xu, S. [1 ]
Mathews, A. [1 ]
McVeigh, E. R. [2 ]
Stayman, J. W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Univ Calif San Diego, Dept Bioengn, Med, Radiol, La Jolla, CA 92093 USA
关键词
CT reconstruction; implant imaging; metal artifact reduction; penalized-likelihood estimation; METAL ARTIFACT REDUCTION;
D O I
10.1117/12.2255303
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Atherosclerosis detection remains challenging in coronary CT angiography for patients with cardiac implants. Pacing electrodes of a pacemaker or lead components of a defibrillator can create substantial blooming and streak artifacts in the heart region, severely hindering the visualization of a plaque of interest. We present a novel reconstruction method that incorporates a deformable model for metal leads to eliminate metal artifacts and improve anatomy visualization even near the boundary of the component. Methods: The proposed reconstruction method, referred as STF-dKCR, includes a novel parameterization of the component that integrates deformation, a 3D-2D preregistration process that estimates component shape and position, and a polyenergetic forward model for x-ray propagation through the component where the spectral properties are jointly estimated. The methodology was tested on physical data of a cardiac phantom acquired on a CBCT testbench. The phantom included a simulated vessel, a metal wire emulating a pacing lead, and a small Teflon sphere attached to the vessel wall, mimicking a calcified plaque. The proposed method was also compared to the traditional FBP reconstruction and an interpolation-based metal correction method (FBP-MAR). Results: Metal artifacts presented in standard FBP reconstruction were significantly reduced in both FBP-MAR and STF-dKCR, yet only the STF-dKCR approach significantly improved the visibility of the small Teflon target (within 2 mm of the metal wire). The attenuation of the Teflon bead improved to 0.0481 mm(-1) with STF-dKCR from 0.0166 mm(-1) with FBP and from 0.0301 mm(-1) with FBP-MAR - much closer to the expected 0.0414 mm(-1). Conclusion: The proposed method has the potential to improve plaque visualization in coronary CT angiography in the presence of wire-shaped metal components.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Kuya, Keita
    Shinohara, Yuki
    Sakamoto, Makoto
    Iwata, Naoki
    Kishimoto, Junichi
    Fujii, Shinya
    Kaminou, Toshio
    Watanabe, Takashi
    Ogawa, Toshihide
    NEURORADIOLOGY, 2014, 56 (11) : 947 - 953
  • [22] CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Keita Kuya
    Yuki Shinohara
    Makoto Sakamoto
    Naoki Iwata
    Junichi Kishimoto
    Shinya Fujii
    Toshio Kaminou
    Takashi Watanabe
    Toshihide Ogawa
    Neuroradiology, 2014, 56 : 947 - 953
  • [23] Geometrically deformable models for model-based reconstruction of objects from range images
    Gurke, S
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 824 - 829
  • [24] Improved Delineation of the Anterior Spinal Artery With Model-Based Iterative Reconstruction in CT Angiography: A Clinical Pilot Study
    Machida, Haruhiko
    Tanaka, Isao
    Fukui, Rika
    Kita, Kazuyo
    Shen, Yun
    Ueno, Eiko
    Suzuki, Shigeru
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) : 442 - 446
  • [25] Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography
    Karolyi, Mihaly
    Szilveszter, Balint
    Kolossvary, Marton
    Takx, Richard A. P.
    Celeng, Csilla
    Bartykowszki, Andrea
    Jermendy, Adam L.
    Panajotu, Alexisz
    Karady, Jlia
    Raaijmakers, Rolf
    Giepmans, Walter
    Merkely, Bela
    Maurovich-Horvat, Pal
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 83 - 89
  • [26] Deformable model-based segmentation of 3D CT by matching distributions
    Radke, R
    Freedman, D
    Zhang, T
    Jeong, Y
    Chen, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1846 - 1846
  • [27] Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique
    Scheffel, Hans
    Stolzmann, Paul
    Schlett, Christopher L.
    Engel, Leif-Christopher
    Major, Gyoengi Petra
    Karolyi, Mihaly
    Do, Synho
    Maurovich-Horvat, Pal
    Hoffmann, Udo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E363 - E369
  • [28] Model-Based Reconstruction of Spectral and Spatial Source Distribution for Objects With Known Motion
    Jaworski, Jason M.
    Wahl, Christopher G.
    Wang, Weiyi
    Fessler, Jeffrey A.
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3981 - 3989
  • [29] Coronary Artery Stent Evalurtion with Modell-based lteratilve Reconstruction Coronary CT Angiography
    Tatsugami, Fuminari
    Higaki, Toru
    Sakane, Hiroaki
    Fukumoto, Wataru
    Kaichi, Yoko
    Iida, Makoto
    Baba, Yasutaka
    Kiguchi, Masao
    Kihara, Yasuki
    Tsushima, So
    Awai, Kazuo
    ACADEMIC RADIOLOGY, 2017, 24 (08) : 975 - 981
  • [30] A General CT Reconstruction Algorithm for Model-Based Material Decomposition
    Tilley, Steven
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573