Enhancement and integration of desiccant evaporative cooling system model calibrated and validated under transient operating conditions

被引:7
|
作者
Ali, Muzaffar [1 ,2 ]
Vukovic, Vladimir [3 ]
Sheikh, Nadeem Ahmed [4 ]
Ali, Hafiz M. [2 ]
Sahir, Mukhtar Hussain [2 ]
机构
[1] Austrian Inst Technol, Dept Energy, A-1210 Vienna, Austria
[2] Univ Engn & Technol Taxila, Dept Mech Engn, Taxila, Pakistan
[3] Univ Teesside, Sch Sci & Engn, Technol Futures Inst, Tees Valley, Middx, England
[4] Muhammad Ali Jinnah Univ, Dept Mech Engn, Karachi, Pakistan
关键词
Desiccant cooling system; Equation-based object oriented modeling; Enhanced system model; Real system operation; Dymola/Modelica; ENERGY WHEEL EFFECTIVENESS; PART II; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2014.10.064
中图分类号
O414.1 [热力学];
学科分类号
摘要
Desiccant cooling systems provide new possibilities in air conditioning technology through the use of either solid or liquid sorption air dehumidification. Such systems can be more reliable and environmental friendly than the conventional systems. The focus of current study is to enhance the existing ideal system component models of the desiccant evaporative cooling system (DEC) developed in an equation-based object-oriented modeling and simulation program, Dymola/Modelica to address the real component operation. Initially, the enhanced component models are calibrated and validated through the transient measurements obtained from the real DEC system installation. Afterward, using the validated physical models of individual components, complete system model has been experimentally calibrated and validated. The obtained results are in good agreement with the actual measurements at the both component and system levels. At the system level, in terms of specific enthalpy of supply air, the resulting maximum and minimum root mean square error (RMSE) and mean percentage error (MPE) between the simulated and measured transient performance is 0.96 kJ/kg and 1.53%. The results show that the enhanced system model is able to predict the performance of the real desiccant cooling system with good accuracy. As such, the current paper contributes to the efforts of bringing simulations closer to performance of real systems under building operating conditions. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1093 / 1105
页数:13
相关论文
共 50 条
  • [31] Experimental investigation of a hybrid photovoltaic evaporative cooling (PV/EC) system performance under arid conditions
    Mahmood, Deyaa M. N.
    Aljubury, Issam M. Ali
    RESULTS IN ENGINEERING, 2022, 15
  • [32] Investigation and assessment of the optimum conditions of solar heat source hybrid desiccant cooling system under different modes
    Seung, Dohyun
    Min, Seojun
    Caliskan, Hakan
    Hong, Hiki
    SOLAR ENERGY, 2023, 265
  • [33] Evaluation of the cooling potential of a vertical greenery system coupled to a building through an experimentally validated transient model
    Detommaso, Maurizio
    Costanzo, Vincenzo
    Nocera, Francesco
    Evola, Gianpiero
    BUILDING AND ENVIRONMENT, 2023, 244
  • [34] Analysis of a combined heating and cooling system model under different operating strategies
    Dzierzgowski, Mieczyslaw
    Zwierzchowski, Ryszard
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [35] An equivalent circuit model for simulation of the ggNMOS transient triggering under ESD operating conditions
    Grisel, R.
    Coyitangiye, L. A.
    Doukkali, A.
    Barbier, F.
    Descamps, P.
    Murray, H.
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 1704 - +
  • [36] A Unified Model for System Reliability Evaluation Under Dynamic Operating Conditions
    Xu, Ancha
    Zhou, Shirong
    Tang, Yincai
    IEEE TRANSACTIONS ON RELIABILITY, 2021, 70 (01) : 65 - 72
  • [37] Enhancing outdoor thermal comfort in hot humid climates by forming dry cool region under canopy using desiccant-evaporative cooling system
    Hatoum, Hilda
    Younes, Jaafar
    Ghali, Kamel
    Ghaddar, Nesreen
    BUILDING AND ENVIRONMENT, 2025, 277
  • [38] EXPERIMENTAL PERFORMANCE OF A TURBO-COMPRESSION COOLING SYSTEM OPERATING UNDER POWER PLANT CONDITIONS
    Garland, Shane D.
    Bandhauer, Todd M.
    5TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, TFEC 2020, 2020, : 243 - 246
  • [39] Analysis of the Performance of a Passive Downdraught Evaporative Cooling System Driven by Solar Chimneys in a Residential Building by Using an Experimentally Validated TRNSYS Model
    Soto, Andres
    Martinez, Pedro
    Soto, Victor M.
    Martinez, Pedro J.
    ENERGIES, 2021, 14 (12)
  • [40] IDENTIFICATION OF A SIMULATION-MODEL AND A CONTROL MODEL FOR A COKE-OVEN BATTERY OPERATING UNDER TRANSIENT CONDITIONS
    BENARD, C
    ROSSETLOUERAT, MM
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1992, 114 (03): : 444 - 453