BEAM PROFILE INVESTIGATION OF THE NEW COLLIMATOR SYSTEM FOR THE J-PET DETECTOR

被引:4
|
作者
Kubicz, E. [1 ]
Silarski, M. [1 ]
Wieczorek, A. [1 ,2 ]
Alfs, D. [1 ]
Bednarski, T. [1 ]
Bialas, P. [1 ]
Czerwinski, E. [1 ]
Gajos, A. [1 ]
Glowacz, B. [1 ]
Jasinska, B. [3 ]
Kaminska, D. [1 ]
Korcyl, G. [1 ]
Kowalski, P. [4 ]
Kozik, T. [1 ]
Krzemien, W. [5 ]
Mohammed, M. [1 ]
Moskal, I. [1 ]
Niedzwiecki, S. [1 ]
Pawlik-Niedzwiecka, M. [1 ]
Raczynski, L. [5 ]
Rudy, Z. [1 ]
Strzelecki, A. [1 ]
Wislicki, W. [5 ]
Zielinski, M. [1 ]
Zgardzinska, B. [3 ]
Moskal, P. [1 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, Lojasiewicza 11, PL-30348 Krakow, Poland
[2] Polish Acad Sci, Inst Met & Mat Sci, Reymonta 25, PL-30059 Krakow, Poland
[3] Marie Curie Sklodowska Univ, Inst Phys, Dept Nucl Methods, Pl M Curie Sklodowskiej 1, PL-20031 Lublin, Poland
[4] Natl Ctr Nucl Res, Swierk Comp Ctr, Soltana 7, PL-05400 Otwock, Poland
[5] Natl Ctr Nucl Res, Div High Energy Phys, Soltana 7, PL-05400 Otwock, Poland
来源
ACTA PHYSICA POLONICA B | 2016年 / 47卷 / 02期
关键词
HIT-POSITION RECONSTRUCTION; TIME-OF-FLIGHT; PLASTIC SCINTILLATORS; SIGNALS; LIBRARY;
D O I
10.5506/APhysPolB.47.537
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article, we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. We have shown that usage of two lead bricks with dimensions of 5 x 10 x 20 cm(3) enables to form a beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM. Determination of this characteristic is essential for designing and construction the collimator system for the 24-module J-PET prototype. Simulations of the beam profile for different collimator dimensions were performed. This allowed us to choose optimal collimation system in terms of the beam profile parameters, dimensions and weight of the collimator taking into account the design of the 24-module J-PET detector.
引用
收藏
页码:537 / 548
页数:12
相关论文
共 50 条
  • [31] MIRROR MATTER IN ORTHO-POSITRONIUM DECAY SEARCHES USING THE J-PET DETECTOR
    Mędrala-Sowa, Justyna
    Perez del Rio, Elena
    Moskal, Pawel
    Acta Physica Polonica B, Proceedings Supplement, 2024, 17 (07):
  • [32] The J-PET detector-a tool for precision studies of ortho-positronium decays
    Dulski, K.
    Bass, S. D.
    Chhokar, J.
    Chug, N.
    Curceanu, C.
    Czerwinski, E.
    Dagdar, M.
    Gajewski, J.
    Gajos, A.
    Gorgol, M.
    Del Grande, R.
    Hiesmayr, B. C.
    Jasinska, B.
    Kacprzak, K.
    Kaplon, L.
    Karimi, H.
    Kisielewska, D.
    Klimaszewski, K.
    Kopka, P.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Malczak, P.
    Mohammed, M.
    Niedzwiecki, Sz
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Pedziwiatr, M.
    Raczynski, L.
    Raj, J.
    Rucinski, A.
    Sharma, S.
    Shivani
    Shopa, R. Y.
    Silarski, M.
    Skurzok, M.
    Stepien, E. L.
    Tayefi, F.
    Wislicki, W.
    Zgardzinska, B.
    Moskal, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1008
  • [33] Multiple Scattering and Accidental Coincidences in the J-PET Detector Simulated Using GATE Package
    Kowalski, P.
    Moskal, P.
    Wislicki, W.
    Raczynski, L.
    Bednarski, T.
    Bialas, P.
    Bulka, J.
    Czerwinski, E.
    Gajos, A.
    Gruntowski, A.
    Kaminska, D.
    Kaplon, L.
    Kochanowski, A.
    Korcyl, G.
    Kowal, J.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Niedzwiecki, Sz
    Palka, M.
    Rudy, Z.
    Salabura, P.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Wochlik, I.
    Zielinski, M.
    Zon, N.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1505 - 1512
  • [34] J-PET DETECTOR APPROACH FOR TESTING CP SYMMETRY IN THE ORTHO-POSITRONIUM ANNIHILATION
    Eliyan K.V.
    Skurzok M.
    Moskal P.
    Acta Phys. Pol. B Proc. Suppl., 1899, 1 (1A11-1A111): : 1A11 - 1A111
  • [35] Simulation of Positronium Decays in View of Charge Conjugation Symmetry Test with the J-PET Detector
    Chhokar, J.
    ACTA PHYSICA POLONICA A, 2020, 137 (02) : 134 - 136
  • [36] Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
    Moskal, P.
    Krawczyk, N.
    Hiesmayr, B. C.
    Bala, M.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Gorgol, M.
    Del Grande, R.
    Jasinska, B.
    Kacprzak, K.
    Kaplon, L.
    Kisielewska, D.
    Klimaszewski, K.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Sharma, S.
    Silarski, M.
    Shivani
    Shopa, R. Y.
    Skurzok, M.
    Wislicki, W.
    Zgardzinska, B.
    EUROPEAN PHYSICAL JOURNAL C, 2018, 78 (11):
  • [37] TOWARDS IMPROVING THE SENSITIVITY OF THE CPT SYMMETRY IN POSITRONIUM DECAYS WITH THE MODULAR J-PET DETECTOR
    Chug, N.
    Gajos, A.
    ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT, 2022, 15 (04)
  • [38] Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology: A Simulation Study
    Dadgar, M.
    Parzych, S.
    Tayefi Ardebili, F.
    Baran, J.
    Chug, N.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Eliyan, K.
    Gajos, A.
    Hiesmayr, B. C.
    Kacprzak, K.
    Kaplon, L.
    Klimaszewski, K.
    Konieczka, P.
    Korcyl, G.
    Kozik, T.
    Krzemien, W.
    Kumar, D.
    Niedzwiecki, S.
    Panek, D.
    Perez del Rio, E.
    Raczynski, L.
    Sharma, S.
    Shopa, R. Y.
    Skurzok, M.
    Tayefi Ardebili, K.
    Vandenberghe, S.
    Wislicki, W.
    Stepien, E. L.
    Moskal, P.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (02) : 124 - 131
  • [39] Time Over Threshold as a measure of energy response of plastic scintillators used in the J-PET detector
    Sharma, Sushil
    MESON 2018 - 15TH INTERNATIONAL WORKSHOP ON MESON PHYSICS, 2019, 199
  • [40] Determination of the map of efficiency of the Jagiellonian Positron Emission Tomograph (J-PET) detector with the GATE package
    Kowalski, Pawel
    Raczynski, Lech
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Giergiel, Krzysztof
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kozik, Tomasz
    Krzemien, Wojciech
    Molenda, Marcin
    Moskal, Ines
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik-Niedzwiecka, Monika
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Strzelecki, Adam
    Szymanski, Konrad
    Wislicki, Wojciech
    Witkowski, Piotr
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (02) : 85 - 90