BEAM PROFILE INVESTIGATION OF THE NEW COLLIMATOR SYSTEM FOR THE J-PET DETECTOR

被引:4
|
作者
Kubicz, E. [1 ]
Silarski, M. [1 ]
Wieczorek, A. [1 ,2 ]
Alfs, D. [1 ]
Bednarski, T. [1 ]
Bialas, P. [1 ]
Czerwinski, E. [1 ]
Gajos, A. [1 ]
Glowacz, B. [1 ]
Jasinska, B. [3 ]
Kaminska, D. [1 ]
Korcyl, G. [1 ]
Kowalski, P. [4 ]
Kozik, T. [1 ]
Krzemien, W. [5 ]
Mohammed, M. [1 ]
Moskal, I. [1 ]
Niedzwiecki, S. [1 ]
Pawlik-Niedzwiecka, M. [1 ]
Raczynski, L. [5 ]
Rudy, Z. [1 ]
Strzelecki, A. [1 ]
Wislicki, W. [5 ]
Zielinski, M. [1 ]
Zgardzinska, B. [3 ]
Moskal, P. [1 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, Lojasiewicza 11, PL-30348 Krakow, Poland
[2] Polish Acad Sci, Inst Met & Mat Sci, Reymonta 25, PL-30059 Krakow, Poland
[3] Marie Curie Sklodowska Univ, Inst Phys, Dept Nucl Methods, Pl M Curie Sklodowskiej 1, PL-20031 Lublin, Poland
[4] Natl Ctr Nucl Res, Swierk Comp Ctr, Soltana 7, PL-05400 Otwock, Poland
[5] Natl Ctr Nucl Res, Div High Energy Phys, Soltana 7, PL-05400 Otwock, Poland
来源
ACTA PHYSICA POLONICA B | 2016年 / 47卷 / 02期
关键词
HIT-POSITION RECONSTRUCTION; TIME-OF-FLIGHT; PLASTIC SCINTILLATORS; SIGNALS; LIBRARY;
D O I
10.5506/APhysPolB.47.537
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article, we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. We have shown that usage of two lead bricks with dimensions of 5 x 10 x 20 cm(3) enables to form a beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM. Determination of this characteristic is essential for designing and construction the collimator system for the 24-module J-PET prototype. Simulations of the beam profile for different collimator dimensions were performed. This allowed us to choose optimal collimation system in terms of the beam profile parameters, dimensions and weight of the collimator taking into account the design of the 24-module J-PET detector.
引用
收藏
页码:537 / 548
页数:12
相关论文
共 50 条
  • [1] Time Calibration of the J-PET Detector
    Skurzok, M.
    Silarski, M.
    Alfs, D.
    Bialas, P.
    Shivani
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska-Kaminska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Mohammed, Muhsin
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Sharma, N. G.
    Sharma, S.
    Shopa, R. Y.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA A, 2017, 132 (05) : 1641 - 1644
  • [2] Sensitivity of Discrete Symmetry Tests in the Positronium System with the J-PET Detector
    Gajos, Aleksander
    SYMMETRY-BASEL, 2020, 12 (08):
  • [3] Mirror Matter Searches with the J-PET Detector
    del Rio, E. Perez
    Krzemien, W.
    Klosek, B.
    ACTA PHYSICA POLONICA A, 2022, 142 (03) : 386 - 390
  • [4] J-PET detector system for studies of the electron-positron annihilations
    Pawlik-Niedzwiecka, M.
    Khreptak, O.
    Gajos, A.
    Wieczorek, A.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Glowacz, B.
    Gupta-Sharma, N.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kaminska, D.
    Korcyl, G.
    Kowalski, P.
    Krzmien, W.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Raczynski, L.
    Rudy, Z.
    Silarski, M.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    MESON 2016 - 14TH INTERNATIONAL WORKSHOP ON MESON PRODUCTION, PROPERTIES AND INTERACTION, 2016, 130
  • [5] Calibration of photomultipliers gain used in the J-PET detector
    Bednarski, Tomasz
    Czerwinski, Eryk
    Moskal, Pawel
    Bialas, Piotr
    Giergiel, Krzysztof
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Molenda, Marcin
    Moskal, Ines
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha Gupta
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Strzelecki, Adam
    Szymanski, Konrad Jan
    Wislicki, Wojciech
    Witkowski, Piotr
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 13 - 17
  • [6] Preliminary Studies of J-PET Detector Spatial Resolution
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Alfs, D.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Palka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Shivani
    Silarski, M.
    Skurzok, M.
    Sharma, N. G.
    Sharma, S.
    Shopa, R. Y.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA A, 2017, 132 (05) : 1645 - 1648
  • [7] Physics beyond the Standard Model with the J-PET detector
    Pérez del Río, Elena
    arXiv, 2021,
  • [8] J-PET analysis framework for the prototype TOF-PET detector
    Krzemien, Wojciech
    Silarski, Michal
    Stola, Karol
    Trybek, Damian
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kowalski, Pawel
    Kozik, Tomasz
    Molenda, Marcin
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha Gupta
    Slomski, Artur
    Smyrski, Jerzy
    Strzelecki, Adam
    Wislicki, Wojciech
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 33 - 36
  • [9] Tests of discrete symmetries in positronium decays with the J-PET detector
    Czerwinski, E.
    6TH SYMPOSIUM ON PROSPECTS IN THE PHYSICS OF DISCRETE SYMMETRIES - DISCRETE 2018, 2020, 1586
  • [10] Tests of discrete symmetries in positronium decays with the J-PET detector
    Silarski, Michal
    MESON 2018 - 15TH INTERNATIONAL WORKSHOP ON MESON PHYSICS, 2019, 199