Attenuation correction for cardiac dual-head γ camera coincidence imaging using segmented myocardial perfusion SPECT

被引:0
|
作者
Fukuchi, K
Sago, M
Nita, K
Fukushima, K
Toba, M
Hayashida, K
Takamiya, M
Ishida, Y
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Suita, Osaka 5658565, Japan
[2] Sumitomo Met Ind Ltd, Div Biomed, Tokyo, Japan
关键词
FDG; coincidence gamma camera imaging; PET; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic accuracy of cardiac FDG imaging obtained with the dual-head coincidence gamma camera (DHC) is impaired by artifacts induced by nonuniform attenuation. This study proposed a new method (registration and segmentation method for attenuation correction [AC-RS]) to correct these attenuations in the chest region without the need for additional hardware or expensive transmission scanning equipment. Methods: Before DHC imaging, Tc-99m-tetrofosmin SPECT was performed using dual-energy acquisition from both the photopeak and Compton scatter windows. The scatter window images of the Tc-99m-tetrofosmin were then registered 3-dimensionally with the cardiac DHC images and segmented into anatomic regions to obtain body and lung contours by applying the optimal threshold method on localized histograms. Theoretic attenuation coefficient Values were assigned to the corresponding anatomic regions, and the DHC emission images were reconstructed using these attenuation correction factors. The results were quantitatively evaluated by imaging a cardiac phantom filled with a uniform solution and placed in a chest phantom. Eight nondiabetic subjects were also examined using this technique, and the results were compared with those of measured attenuation-corrected PET images. Results: Use of this technique in phantom and clinical studies decreased the degree of artifacts seen in the inferior wall activity and corrected the emission images. When the results were compared with those of PET scans, the regional relative counts of the uncorrected DHC scan did not correlate with the results of the PET scan. However, the regional relative counts of the AG-RS-corrected DHC scan exhibited a linear correlation with the results of the PET scan (r = 0.73; P < 0.001), Conclusion: Reasonably accurate attenuation-corrected cardiac DHC images can be obtained using AC-RS without the need for transmission scanning.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 50 条
  • [21] Attenuation correction for myocardial perfusion SPECT imaging: still a controversial issue
    Cuocolo, Alberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (10) : 1887 - 1889
  • [22] Attenuation correction for myocardial perfusion SPECT imaging: still a controversial issue
    Alberto Cuocolo
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 1887 - 1889
  • [23] Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Liu, Bin
    Ou, Xiaohong
    Tian, Rong
    Li, Lin
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) : 344 - 349
  • [24] Initial coincidence imaging experience with a SPECT/PET dual head camera.
    Glass, EC
    Nelleman, P
    Hines, H
    Mandelkern, MA
    Blahd, WH
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 203 - 203
  • [25] Correction of heart motion in myocardial tomoscintigraphy with a 90 degrees dual-head camera.
    Gremillet, E
    Champailler, A
    Wartski, M
    Blasco, A
    Guillot, S
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1997, 21 (04): : 214 - 218
  • [26] Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction
    Bernd Nowak
    Michael Zimny
    Ernst Ruediger Schwarz
    Hans-Juergen Kaiser
    Wolfgang Schaefer
    Patrick Reinartz
    Juergen vom Dahl
    Udalrich Buell
    European Journal of Nuclear Medicine, 2000, 27 : 1501 - 1508
  • [27] Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction
    Nowak, B
    Zimny, M
    Schwarz, ER
    Kaiser, HJ
    Schaefer, W
    Reinartz, P
    vom Dahl, J
    Buell, U
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (10) : 1501 - 1508
  • [28] Attenuation correction of thallium myocardial perfusion SPECT
    Ryan, PJ
    Hausenlot, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1232 - 1232
  • [29] Interference of neighboring activity to coincidence imaging with non-homogeneous attenuation correction on a dual head gamma camera
    Luo, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1462 - 1462
  • [30] Synthetic Attenuation Correction Maps for SPECT Imaging using Deep Learning: A Study on Myocardial Perfusion Imaging
    Namias, M.
    Prieto Canalejo, M. A.
    San Pedro, A. Palau
    Geronazzo, R.
    Minsky, D. M.
    Juarez Orozco, L. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S270 - S271