Pulmonary nodules: Effect on detection of spiral CT pitch

被引:33
|
作者
Wright, AR [1 ]
Collie, DA [1 ]
Williams, JR [1 ]
HashemiMalayeri, B [1 ]
Stevenson, AJM [1 ]
Turnbull, CM [1 ]
机构
[1] WESTERN GEN HOSP,DEPT MED PHYS & MED ENGN,EDINBURGH EH4 2XU,MIDLOTHIAN,SCOTLAND
关键词
lung; nodule; 60.332; 60.333; lung neoplasms; CT; 60.12115; staging;
D O I
10.1148/radiology.199.3.8638014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare spiral computed tomography (CT) performed at increased pitch with spiral CT performed at standard pitch in the detection of pulmonary nodules. MATERIALS AND METHODS: Spiral CT scanning of the thorax was performed with a pitch of 1.0 in 109 patients with pulmonary nodules due to metastases. The patients were also randomly assigned to undergo further scanning with a pitch of 1.2 (n = 34), 1.5 (n = 37), or 2.0 (n = 38) at the same scanning session. The scan pairs were analyzed for number, size, and distribution of nodules. RESULTS: A bias toward undercounting was noted on scans with a pitch of 1.5 and 2.0; however, this was not statistically significant. Correlation coefficients were r = .982, r = .977, and r = .989 for scans of pitch 1.2, 1.5, and 2.0, respectively. Disease in one patient would have been prospectively understaged from findings on a scan of pitch 2.0 because of poor conspicuity of a small solitary nodule. CONCLUSION: Findings from scans with increased pitch generally agree well with those from scans with standard pitch; however, there is a greater risk of understaging of disease in patients with solitary nodules as pitch increases. Pitch should be limited to no greater than 1.5 for initial staging of pulmonary metastatic disease.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [21] Application effect of low-dose spiral CT on pulmonary nodules and its diagnostic value for benign and malignant nodules
    Zheng, Chengquan
    Wang, Haofeng
    Liu, Qiaozheng
    Han, Dong
    Xin, Yufei
    Lu, Weina
    Yan, Zhenchong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (01): : 256 - 263
  • [22] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Dag Wormanns
    Martin Fiebich
    Mustafa Saidi
    Stefan Diederich
    Walter Heindel
    European Radiology, 2002, 12 : 1052 - 1057
  • [23] Dose reduction in spiral CT of the thorax: Detection of pulmonary nodules with and without anatomically adapted current modulation
    Greess, H
    Baum, U
    Lell, M
    Wolf, H
    Kalender, WA
    Bautz, WA
    RADIOLOGY, 1999, 213P : 304 - 304
  • [24] Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system
    Wormanns, D
    Fiebich, M
    Saidi, M
    Diederich, S
    Heindel, W
    EUROPEAN RADIOLOGY, 2002, 12 (05) : 1052 - 1057
  • [25] Dose reduction in spiral CT:: Detection of pulmonary nodules with and without anatomic adaptation of tube current.
    Greess, H
    Baum, U
    Wolf, H
    Lell, M
    Nömayr, A
    Schmidt, B
    Kalender, WA
    Bautz, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05): : 466 - 470
  • [26] Computerized detection of pulmonary nodules in CT scans
    Armato, SG
    Giger, ML
    Moran, CJ
    Doi, K
    MacMahon, H
    RADIOLOGY, 1998, 209P : 161 - 161
  • [27] Computerized detection of pulmonary nodules on CT scans
    Armato, SG
    Giger, ML
    Moran, CJ
    Blackburn, JT
    Doi, K
    MacMahon, H
    RADIOGRAPHICS, 1999, 19 (05) : 1303 - 1311
  • [28] Automated detection of pulmonary nodules in CT scans
    Antonelli, M.
    Frosini, G.
    Lazzerini, B.
    Marcelloni, F.
    INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE FOR MODELLING, CONTROL & AUTOMATION JOINTLY WITH INTERNATIONAL CONFERENCE ON INTELLIGENT AGENTS, WEB TECHNOLOGIES & INTERNET COMMERCE, VOL 2, PROCEEDINGS, 2006, : 799 - +
  • [29] Optimal pitch of spiral CT
    Wang, G
    Vannier, MW
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 79 - 82
  • [30] Spiral CT of pulmonary nodules: interobserver variation in assessment of lesion size
    D. Wormanns
    S. Diederich
    M. G. Lentschig
    F. Winter
    W. Heindel
    European Radiology, 2000, 10 : 710 - 713