Electrochemical Glucose Sensors Enhanced by Methyl Viologen and Vertically Aligned Carbon Nanotube Channels

被引:42
|
作者
Brownlee, Benjamin J. [1 ]
Bahari, Meisam [2 ]
Harb, John N. [2 ]
Claussen, Jonathan C. [3 ]
Iverson, Brian D. [1 ]
机构
[1] Brigham Young Univ, Dept Mech Engn, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Chem Engn, Provo, UT 84602 USA
[3] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
关键词
electrochemical sensor; glucose; methyl viologen; vertically aligned carbon nanotubes (VACNTs); microchannel; flow injection analysis (FIA); UNDERWATER VEHICLE PROPULSION; BIOFUEL CELLS; PLATINUM NANOPARTICLES; DIABETES-MELLITUS; BIOSENSORS; OXIDATION; ELECTRODE; OXIDASE; MICRO; IMMOBILIZATION;
D O I
10.1021/acsami.8b08997
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Freestanding, vertically aligned carbon nano tubes (VACNTs) were patterned into 16 mu m diameter microchannel arrays for flow-through electrochemical glucose sensing. Non-enzymatic sensing of glucose was achieved by the chemical reaction of glucose with methyl viologen (MV) at an elevated temperature and pH (0.1 M NaOH), followed by the electrochemical reaction of reduced-MV with the VACNT surface. The MV sensor required no functionalization (including no metal) and was able to produce on average 3.4 electrons per glucose molecule. The current density of the MV sensor was linear with both flow rate and glucose concentration. Challenges with interference chemicals were mitigated by operating at a low potential of -0.2 V vs Ag/AgCl. As a comparison, enzymatic VACNT sensors with platinum nano-urchins were functionalized with glucose oxidase by covalent binding (1-ethyl-3-(-3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide) or by polymer entrapment [poly(3,4-ethylene-dioxythiophene)] and operated in phosphate buffered saline. With normalization by the overall cross-sectional area of the flow (0.713 cm(2)), the sensitivity of the MV, enzyme-in solution, and covalent sensors were 45.93, 18.77, and 1.815 mA cm(-2) mM(-1), respectively. Corresponding limits of detection were 100, 194, and 311 nM glucose. The linear sensing ranges for the sensors were 250 nM to 200 mu M glucose for the MV sensor, 500 nM to 200 mu M glucose for the enzyme-in-solution sensor, and 1 mu M to 6 mM glucose for the covalent sensor. The flow cell and sensor cross-sectional area were scaled down (0.020 cm(2)) to enable detection from 200 mu L of glucose with MV by flow injection analysis. The sensitivity of the small MV sensor was 5.002 mA cm(-2) mM(-1), with a limit of detection of 360 nM glucose and a linear range up to at least 150 mu M glucose. The small MV sensor has the potential to measure glucose levels found in 200 mu L of saliva.
引用
收藏
页码:28351 / 28360
页数:10
相关论文
共 50 条
  • [21] Growth Mechanism of Vertically Aligned Carbon Nanotube Arrays
    Zhang, Ji-cheng
    Tang, Yong-jian
    Yi, Yong
    Zhou, Min-jie
    Ma, Kang-fu
    Wu, Wei-dong
    Wang, Chao-yang
    Zhao, Yon
    Luo, Bing-chi
    Wang, Zhuo
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2015, 28 (05) : 617 - 622
  • [22] Thermoelectric Property of Vertically Aligned Carbon Nanotube Carpets
    Li, Y. R.
    Su, C. C.
    Chang, S. H.
    2015 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2015, : 310 - 313
  • [23] Modelling clustering of vertically aligned carbon nanotube arrays
    Schaber, Clemens F.
    Filippov, Alexander E.
    Heinlein, Thorsten
    Schneider, Joerg J.
    Gorb, Stanislav N.
    INTERFACE FOCUS, 2015, 5 (04)
  • [24] Frictional behaviour of vertically aligned carbon nanotube films
    Zhang, Wei
    Xu, Binshi
    Tanaka, Akihiro
    Koga, Yoshinori
    CARBON, 2009, 47 (03) : 926 - 929
  • [25] Preparation of Co-Ni Oxide/Vertically Aligned Carbon Nanotube and Their Electrochemical Performance in Supercapacitors
    Saghafi, M.
    Mahboubi, F.
    Mohajerzadeh, S.
    Holze, R.
    MATERIALS AND MANUFACTURING PROCESSES, 2015, 30 (01) : 70 - 78
  • [26] 3D Interdigitated Vertically Aligned Carbon Nanotube Electrodes for Electrochemical Impedimetric Biosensing
    Brownlee, Benjamin J.
    Claussen, Jonathan C.
    Iverson, Brian D.
    ACS APPLIED NANO MATERIALS, 2020, 3 (10) : 10166 - 10175
  • [27] Electrochemical Charge Storage Properties of Vertically Aligned Carbon Nanotube Films: Effects of Thermal Oxidation
    Brown, Billyde
    Parker, Charles B.
    Stoner, Brian R.
    Grill, Warren M.
    Glass, Jeffrey T.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (36): : 19526 - 19534
  • [28] Enhanced field emission properties of vertically aligned double-walled carbon nanotube arrays
    Chen, Guohai
    Shin, Dong Hoon
    Iwasaki, Takayuki
    Kawarada, Hiroshi
    Lee, Cheol Jin
    NANOTECHNOLOGY, 2008, 19 (41)
  • [29] Metal-modified and vertically aligned carbon nanotube sensors array for landfill gas monitoring applications
    Penza, M.
    Rossi, R.
    Alvisi, M.
    Serra, E.
    NANOTECHNOLOGY, 2010, 21 (10)
  • [30] Carbon Nanotube Selective Membranes with Subnanometer, Vertically Aligned Pores, and Enhanced Gas Transport Properties
    Labropoulos, Anastasios
    Veziri, Charitomeni
    Kapsi, Maria
    Pilatos, George
    Likodimos, Vlassis
    Tsapatsis, Michael
    Kanellopoulos, Nick K.
    Romanos, George E.
    Karanikolos, Georgios N.
    CHEMISTRY OF MATERIALS, 2015, 27 (24) : 8198 - 8210