Electrochemical Glucose Sensors Enhanced by Methyl Viologen and Vertically Aligned Carbon Nanotube Channels

被引:42
|
作者
Brownlee, Benjamin J. [1 ]
Bahari, Meisam [2 ]
Harb, John N. [2 ]
Claussen, Jonathan C. [3 ]
Iverson, Brian D. [1 ]
机构
[1] Brigham Young Univ, Dept Mech Engn, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Chem Engn, Provo, UT 84602 USA
[3] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
关键词
electrochemical sensor; glucose; methyl viologen; vertically aligned carbon nanotubes (VACNTs); microchannel; flow injection analysis (FIA); UNDERWATER VEHICLE PROPULSION; BIOFUEL CELLS; PLATINUM NANOPARTICLES; DIABETES-MELLITUS; BIOSENSORS; OXIDATION; ELECTRODE; OXIDASE; MICRO; IMMOBILIZATION;
D O I
10.1021/acsami.8b08997
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Freestanding, vertically aligned carbon nano tubes (VACNTs) were patterned into 16 mu m diameter microchannel arrays for flow-through electrochemical glucose sensing. Non-enzymatic sensing of glucose was achieved by the chemical reaction of glucose with methyl viologen (MV) at an elevated temperature and pH (0.1 M NaOH), followed by the electrochemical reaction of reduced-MV with the VACNT surface. The MV sensor required no functionalization (including no metal) and was able to produce on average 3.4 electrons per glucose molecule. The current density of the MV sensor was linear with both flow rate and glucose concentration. Challenges with interference chemicals were mitigated by operating at a low potential of -0.2 V vs Ag/AgCl. As a comparison, enzymatic VACNT sensors with platinum nano-urchins were functionalized with glucose oxidase by covalent binding (1-ethyl-3-(-3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide) or by polymer entrapment [poly(3,4-ethylene-dioxythiophene)] and operated in phosphate buffered saline. With normalization by the overall cross-sectional area of the flow (0.713 cm(2)), the sensitivity of the MV, enzyme-in solution, and covalent sensors were 45.93, 18.77, and 1.815 mA cm(-2) mM(-1), respectively. Corresponding limits of detection were 100, 194, and 311 nM glucose. The linear sensing ranges for the sensors were 250 nM to 200 mu M glucose for the MV sensor, 500 nM to 200 mu M glucose for the enzyme-in-solution sensor, and 1 mu M to 6 mM glucose for the covalent sensor. The flow cell and sensor cross-sectional area were scaled down (0.020 cm(2)) to enable detection from 200 mu L of glucose with MV by flow injection analysis. The sensitivity of the small MV sensor was 5.002 mA cm(-2) mM(-1), with a limit of detection of 360 nM glucose and a linear range up to at least 150 mu M glucose. The small MV sensor has the potential to measure glucose levels found in 200 mu L of saliva.
引用
收藏
页码:28351 / 28360
页数:10
相关论文
共 50 条
  • [1] Electrochemical modification of vertically aligned carbon nanotube arrays
    Ye, X. R.
    Chen, L. H.
    Wang, C.
    Aubuchon, J. F.
    Chen, I. C.
    Gapin, A. I.
    Talbot, J. B.
    Jin, S.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (26): : 12938 - 12942
  • [2] Enhanced Electrochemical Activity Using Vertically Aligned Carbon Nanotube Electrodes Grown on Carbon Fiber
    de Morais, Evandro Augusto
    Alvial, Gaston
    Longuinhos, Rafael
    Andrade Figueiredo, Jose Marcos
    Lacerda, Rodrigo Gribel
    Ferlauto, Andre Santarosa
    Ladeira, Luiz Orlando
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2011, 14 (03): : 403 - 407
  • [3] Artificial introduction of defects into vertically aligned multiwalled carbon nanotube ensembles: Application to electrochemical sensors
    Nichols, Jeffrey A.
    Saito, Hiroaki
    Deck, Christian
    Bandaru, Prabhakar R.
    JOURNAL OF APPLIED PHYSICS, 2007, 102 (06)
  • [4] Aligned carbon nanotube-DNA electrochemical sensors
    He, PG
    Dai, LM
    CHEMICAL COMMUNICATIONS, 2004, (03) : 348 - 349
  • [5] Microwave vertically aligned carbon nanotube array sensors for ammonia detection
    McGrath, MP
    Phan, A
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 837 - 840
  • [6] Constant Glucose Biosensor Based on Vertically Aligned Carbon Nanotube Composites
    TermehYousefi, Amin
    Bagheri, Samira
    Kadri, Nahrizul Adib
    Mahmood, Mohamad Rusop
    Ikeda, Shoichiro
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (05): : 4183 - 4192
  • [7] Vertically aligned carbon nanotube heterojunctions
    Cassell, AM
    Li, J
    Stevens, RMD
    Koehne, JE
    Delzeit, L
    Ng, HT
    Ye, Q
    Han, J
    Meyyappan, M
    APPLIED PHYSICS LETTERS, 2004, 85 (12) : 2364 - 2366
  • [8] A Novel Two-Electrode Nonenzymatic Electrochemical Glucose Sensor Based on Vertically Aligned Carbon Nanotube Arrays
    Khamsavi, Anousha
    Abdi, Yaser
    Meymian, Mohammadreza Zamani
    IEEE SENSORS LETTERS, 2019, 3 (03)
  • [9] Electrochemical Charge Storage Properties of Vertically Aligned Carbon Nanotube Films: The Activation-Enhanced Length Effect
    Brown, Billyde
    Parker, Charles B.
    Stoner, Brian R.
    Grill, Warren M.
    Glass, Jeffrey T.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2011, 158 (12) : K217 - K224
  • [10] ALD titanium nitride on vertically aligned carbon nanotube forests for electrochemical supercapacitors
    Kao, Emmeline
    Yang, Chen
    Warren, Roseanne
    Kozinda, Alina
    Lin, Liwei
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 240 : 160 - 166