Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: Assessment of response to methacholine and exercise challenge

被引:244
|
作者
Samee, S
Altes, T
Powers, P
de Lange, EE
Knight-Scott, J
Rakes, G
Mugler, JP
Ciambotti, JM
Alford, BA
Brookeman, JR
Platts-Mills, TAE
机构
[1] Univ Virginia, Hlth Syst, Asthma & Allerg Dis Ctr, Dept Internal Med,Div Asthma Allergy & Immunol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Radiol, Charlottesville, VA 22903 USA
[3] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
关键词
asthma; helium; magnetic resonance imaging; imaging; ventilation; lungs;
D O I
10.1067/mai.2003.1544
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Imaging of gas distribution in the lungs of patients with asthma has been restricted because of the lack of a suitable gaseous contrast agent. Hyperpolarized helium-3 (HHe3) provides a new technique for magnetic resonance imaging of lung diseases. Objective: We sought to investigate the use of HHe3 gas to image the lungs of patients with moderate or severe asthma and to assess changes in gas distribution after methacholine and exercise challenge. Methods: Magnetic resonance imaging was performed in asthmatic patients immediately after inhalation of HHe3 gas. In addition, images were obtained before and after methacholine challenge and a standard exercise test. Results: Areas of the lung with no signal or sharply reduced HHe3 signal (ventilation defects) are common in patients with asthma, and the number of defects was inversely related to the percent predicted FEV1 (r = 0.71, P < .002). After methacholine challenge (n = 3), the number of defects increased. Similarly, imaging of the lungs after exercise (n = 6) showed increased ventilation defects in parallel with decreases in FEV1. The increase in defects after challenge in these 9 asthmatic patients was significant both for the number (P < .02) and extent (P < .02) of the defects. The variability and speed of changes in ventilation and the complete lack of signal in many areas is in keeping with a model in which the defects result from airway closure. Conclusion: HHe3 magnetic resonance provides a new technique for imaging the distribution of inhaled air in the lungs. The technique is suitable for following responses to treatment of asthma and changes after methacholine or exercise challenge.
引用
收藏
页码:1205 / 1211
页数:7
相关论文
共 50 条
  • [41] Hyperpolarized Helium-3 Diffusion-weighted Magnetic Resonance Imaging Detects Abnormalities of Lung Structure in Children With Bronchopulmonary Dysplasia
    Flors, Lucia
    Mugler, John P., III
    Paget-Brown, Alix
    Froh, Deborah K.
    de Lange, Eduard E.
    Patrie, James T.
    Altes, Talissa A.
    JOURNAL OF THORACIC IMAGING, 2017, 32 (05) : 323 - 332
  • [42] Analysis of Ventilation Heterogeneity (VH) with Hyperpolarized Helium Magnetic Resonance Imaging (HPHeMRI) Following Inhaled Methacholine (MCH) and Mannitol (MNT) Challenges in Asthmatic Subjects.
    Thompson, B. R.
    Cowen, G.
    Friese, M. E. J.
    Maillet, D.
    Wang, D.
    Eckert, B.
    Upham, J.
    Harris, B.
    King, G. G.
    Thien, F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [43] Mapping and Quantifying Temporal Dynamics of Ventilation Heterogeneity in Cystic Fibrosis Using Hyperpolarized Helium-3 Magnetic Resonance Imaging: Developing New Imaging Measurements for Clinical Trials
    Ahmed, H.
    Choy, S.
    Wheatley, A.
    Etemad-Rezai, R.
    Paterson, N.
    Parraga, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [44] Measurement of Large Airways Using Dynamic 3D Hyperpolarized Helium-3 MR Imaging
    Peterson, E. T.
    Holmes, J. H.
    Dattawadkar, A.
    Agrawal, G.
    Dai, J.
    Jarjour, N. N.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [45] Hyperpolarized helium-3 magnetic resonance lung imaging of non-sedated infants and young children: a proof-of-concept study
    Altes, Talissa A.
    Meyer, Craig H.
    Mata, Jaime F.
    Froh, Deborah K.
    Paget-Brown, Alix
    Teague, W. Gerald
    Fain, Sean B.
    de Lange, Eduard E.
    Ruppert, Kai
    Botfield, Martyn C.
    Johnson, Mac A.
    Mugler, John. P., III
    CLINICAL IMAGING, 2017, 45 : 105 - 110
  • [46] Hyperpolarized 3Helium gas for functional magnetic resonance imaging of the lung
    Heussel, CP
    Gast, KK
    Dahmen, A
    Morbach, AE
    Kauczor, HU
    Schreiber, WG
    Thelen, M
    van Beek, EJR
    MEDIZINISCHE KLINIK, 2005, 100 (07) : 413 - 424
  • [47] Hyperpolarized helium-3 magnetic resonance imaging of asthma: Short-term reproducibility - art. no. 69161X
    Wheatley, Andrew
    McKay, Shayna
    Mathew, Lindsay
    Santyr, Giles
    McCormack, David G.
    Parraga, Grace
    MEDICAL IMAGING 2008: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2008, 6916 : X9161 - X9161
  • [48] HYPERPOLARIZED HELIUM-3 MAGNETIC RESONANCE IMAGING OF CFTR POTENTIATOR THERAPY IN SUBJECTS WITH CYSTIC FIBROSIS AND THE G551D MUTATION
    Altes, T.
    Johnson, M. A.
    Miller, G. W.
    Mugler, J. P.
    Flors, L.
    Mata, J.
    Salinas, C. L.
    Tustison, N.
    Lee, P.
    Song, T.
    Yen, K.
    Froh, D.
    Botfield, M. C.
    PEDIATRIC PULMONOLOGY, 2011, : 284 - 284
  • [49] Use of hyperpolarized helium-3 MRI to assess response to ivacaftor treatment in patients with cystic fibrosis
    Altes, Talissa A.
    Johnson, Mac
    Fidler, Meredith
    Botfield, Martyn
    Tustison, Nicholas J.
    Leiva-Salinas, Carlos
    de lange, Eduard E.
    Froh, Deborah
    Mugler, John P., III
    JOURNAL OF CYSTIC FIBROSIS, 2017, 16 (02) : 267 - 274
  • [50] Quantitative assessment of emphysema using hyperpolarized 3He magnetic resonance imaging
    Spector, ZZ
    Emami, K
    Fischer, MC
    Zhu, J
    Ishii, M
    Vahdat, V
    Yu, J
    Kadlecek, S
    Driehuys, B
    Lipson, DA
    Gefter, W
    Shrager, J
    Rizi, RR
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1341 - 1346