Reconstruction of orbital blowout fractures using MEDPOR titanium mesh implants

被引:1
|
作者
Han, Xiaohui [1 ]
Yang, Shunhai [1 ]
Dong, Zhizhang [1 ]
Feng, Wangqiang [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Ophthalmol, 109 Xueyuan West Rd, Wenzhou 325000, Peoples R China
关键词
Orbital blow-out fracture; titanium mesh (MEDPOR (R) TITAN (TM)); implantation; FLOOR FRACTURES; REPAIR;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of this study was to evaluate the use of titanium mesh (MEDPOR (R) TITAN (TM)) implants in the surgical reconstruction of orbital blowout fractures. A total of 19 patients with orbital blowout fracturesas confirmed with computed tomography who underwent orbital reconstruction with MEDPOR (R) TITAN (TM) implants were evaluated in this study. Postoperative wound healing, vision, eye position, and occurrence of enophthalmos were evaluated and compared. The wounds healed well, and follow-up examination did not show prolapsed or rejected implants. Of 13 cases of diplopia, 11 resolved, 1 persisted but was less severe, and 1 showed no improvement. Surgery did not affect vision, and no significant visual acuity changes were observed. In general, patients were better postoperatively. Eye position improved and all eye movements returned to normal, although 1 case had residual esotropia and diplopia. A total of 19 cases of postoperative enophthalmos were corrected to varying degrees, 15 cases of enophthalmos underwent full correction of protruding eyes, and 4 cases still had mild retraction averaging 0.55 +/- 0.1 mm compared with preoperative enophthalmos, which increased by 1.5 mm to 2 mm. Pre-and postoperative differences were statistically significant. Complications of orbital blowout fractures should be treated early via surgery. A titanium mesh (MEDPOR (R) TITAN (TM)) implant is an excellent material for reconstruction of the orbital wall.
引用
收藏
页码:12411 / 12415
页数:5
相关论文
共 50 条
  • [31] RECONSTRUCTION OF INTERNAL ORBITAL FRACTURES WITH VITALLIUM MESH
    RONCEVIC, R
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (06) : 1176 - 1177
  • [32] Reconstruction of complex orbital fracture with titanium implants
    Yi, Wen-Shu
    Xu, Xue-Liang
    Ma, Jian-Rong
    Ou, Xin-Rong
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (04) : 488 - 492
  • [33] Reconstruction of complex orbital fracture with titanium implants
    Wen-Shu Yi 1
    International Journal of Ophthalmology, 2012, (04) : 488 - 492
  • [34] Orbital floor reconstruction: PDS or titanium mesh?
    Lembo, F.
    Parisi, D.
    Portincasa, A.
    ORAL ONCOLOGY, 2011, 47 : S143 - S143
  • [35] Is Orbital Floor Reconstruction With Titanium Mesh Safe?
    Al-Khdhairi, Omar Bakr Hazm
    Abdulrazaq, Saif Saadedeen
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (07) : E692 - E694
  • [36] Incorporation of titanium mesh in orbital and midface reconstruction
    Schubert, W
    Gear, AJL
    Lee, C
    Hilger, PA
    Haus, E
    Migliori, MR
    Mann, DA
    Benjamin, CI
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 110 (04) : 1022 - 1030
  • [37] Orbital floor reconstruction: pds or titanium mesh?
    Lembo, F.
    Parisi, D.
    Portincasa, A.
    XVII CONGRESSO NAZIONALE DELLA SOCIETA ITALIANA CHIRURGIA MAXILLO-FACCIALE (SICMF), 2011, : 345 - 348
  • [38] ORBITAL BLOWOUT FRACTURES IN SPORT
    JONES, NP
    BRITISH JOURNAL OF SPORTS MEDICINE, 1994, 28 (04) : 272 - 275
  • [39] Pediatric orbital blowout fractures
    Chung, Stella Y.
    Langer, Paul D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2017, 28 (05) : 470 - 476
  • [40] Reply re: "Permanent Versus Bioresorbable Implants in Orbital Floor Blowout Fractures"
    Ramesh, Sathyadeepak
    Goldberg, Robert
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2019, 35 (02): : 202 - 202