Resonance frequency estimation of a bridged loop-gap resonator used for magnetic resonance measurements

被引:20
|
作者
Hirata, H
Ono, M
机构
[1] Dept. of Elec. Eng. and Comp. Sci., Yamagata University, Yonezawa, Yamagata, 992
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 01期
关键词
D O I
10.1063/1.1146554
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents a method for estimating the resonance frequency of a bridged loop-gap resonator (BLGR). It first describes the structure of the BLGR and its equivalent electrical circuit, and then a procedure for calculating the resonance frequency is revealed. In this procedure, node analysis, which is a circuit theory, is applied to calculate the branch voltages of the equivalent circuit. Finally, this paper reports on the calculations and measurements of the resonance frequency, and the validity of the method for estimating resonance frequency. (C) 1996 American Institute of Physics.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [31] Probing split-ring resonator permeabilities with loop-gap resonators
    Bobowski, J. S.
    CANADIAN JOURNAL OF PHYSICS, 2018, 96 (08) : 878 - 886
  • [32] THE CONCENTRIC LOOP-GAP RESONATOR - A COMPACT, BROADLY TUNABLE DESIGN FOR NMR APPLICATIONS
    KOSKINEN, MF
    METZ, KR
    JOURNAL OF MAGNETIC RESONANCE, 1992, 98 (03): : 576 - 588
  • [33] A Novel Loop-Gap Resonator Probehead for EPR and ENDOR at X-Band
    Grishin, Y.
    Kay, C. W. M.
    Doubinskii, A. A.
    Moebius, K.
    Applied Magnetic Resonance, 13 (3-4):
  • [34] A novel loop-gap resonator probehead for EPR and ENDOR at X-band
    Grishin, Y
    Kay, CWM
    Doubinskii, AA
    Mobius, K
    APPLIED MAGNETIC RESONANCE, 1997, 13 (3-4) : 387 - 392
  • [35] A novel loop-gap resonator probehead for EPR and ENDOR at X-band
    Yu. Grishin
    C. W. M. Kay
    A. A. Doubinskii
    K. Möbius
    Applied Magnetic Resonance, 1997, 13 : 387 - 392
  • [36] Automatic coupling control of a loop-gap resonator by a variable capacitor attached coupling coil for EPR measurements at 650 MHz
    Yokoyama, H
    Sato, T
    Ogata, T
    Ohya, H
    Kamada, H
    JOURNAL OF MAGNETIC RESONANCE, 2001, 149 (01) : 29 - 35
  • [37] Novel loop-gap probe head for time-resolved electron paramagnetic resonance at 9.5 GHz
    Elger, G
    Torring, JT
    Mobius, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10): : 3637 - 3641
  • [38] Adjustable coupling and in situ variable frequency electron paramagnetic resonance probe with loop-gap resonators for spectroscopy up to X-band
    Joshi, G.
    Kubasek, J.
    Nikolov, I.
    Sheehan, B.
    Costa, T. A.
    Allao Cassaro, R. A.
    Friedman, Jonathan R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [39] Uniform radio frequency fields in loop-gap resonators for EPR spectroscopy
    R. R. Mett
    J. W. Sidabras
    J. S. Hyde
    Applied Magnetic Resonance, 2007, 31 : 573 - 589
  • [40] A PERIFUSION LOOP-GAP RESONATOR NMR PROBE FOR AEROBIC CELL-SUSPENSIONS
    ANDERSON, ME
    MARKLEY, JL
    ARUS, C
    CHOBANIAN, MC
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) : 563 - 566