Feasibility of a Synthetic MR Imaging Sequence for Spine Imaging

被引:20
|
作者
Vargas, M. I. [1 ]
Drake-Perez, M. [2 ]
Delattre, B. M. A. [3 ]
Boto, J. [1 ]
Lovblad, K-O. [1 ]
Boudabous, S. [3 ]
机构
[1] Geneva Univ Hosp, Div Diagnost & Intervent Neuroradiol, Geneva, Switzerland
[2] Univ Hosp Marques de Valdecilla, IDIVAL, Dept Radiol, Santander, Spain
[3] Geneva Univ Hosp, Div Radiol, Geneva, Switzerland
关键词
PROTON-DENSITY; BRAIN; RELAXATION; QUANTIFICATION; SEGMENTATION; VALIDATION; VALUES;
D O I
10.3174/ajnr.A5728
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Synthetic MR imaging is a method that can produce multiple contrasts from a single sequence, as well as quantitative maps. Our aim was to determine the feasibility of a synthetic MR image for spine imaging. MATERIALS AND METHODS: Thirty-eight patients with clinical indications of infectious, degenerative, and neoplastic disease underwent an MR imaging of the spine (11 cervical, 8 dorsal, and 19 lumbosacral MR imaging studies). The SyntAc sequence, with an acquisition time of 5 minutes 40 seconds, was added to the usual imaging protocol consisting of conventional sagittal T1 TSE, T2 TSE, and STIR TSE. RESULTS: Synthetic T1-weighted, T2-weighted, and STIR images were of adequate quality, and the acquisition time was 53% less than with conventional MR imaging. The image quality was rated as good for both synthetic and conventional images. Interreader agreement concerning lesion conspicuity was good with a Cohen of 0.737. Artifacts consisting of white pixels/spike noise across contrast views, as well as flow artifacts, were more common in the synthetic sequences, particularly in synthetic STIR. There were no statistically significant differences between readers concerning the scores assigned for image quality or lesion conspicuity. CONCLUSIONS: Our study shows that synthetic MR imaging is feasible in spine imaging and produces, in general, good image quality and diagnostic confidence. Furthermore, the non-negligible time savings and the ability to obtain quantitative measurements as well as to generate several contrasts with a single acquisition should promise a bright future for synthetic MR imaging in clinical routine.
引用
收藏
页码:1756 / 1763
页数:8
相关论文
共 50 条
  • [21] IOPHENDYLATE (PANTOPAQUE) AND MR IMAGING OF THE SPINE
    ANAND, AK
    HALTHORE, SN
    WANI, S
    COMPUTERIZED RADIOLOGY, 1987, 11 (04): : 165 - 168
  • [22] MR imaging of the spine in nonaccidental trauma
    Giulio Zuccoli
    Ashok Panigrahy
    Pediatric Radiology, 2010, 40 : 1841 - 1841
  • [23] THE STIR SEQUENCE IN MR IMAGING
    PORTER, BA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1267 - 1267
  • [24] Additional merit of coronal STIR imaging for MR imaging of lumbar spine
    Gupta, Ranjana
    Mittal, Puneet
    Mittal, Amit
    Mittal, Kapish
    Gupta, Sharad
    Kaur, Ravleen
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2015, 6 (01): : 12 - 15
  • [25] MR imaging of the spine in epidermal nevus syndrome
    Booth, TN
    Rollins, NK
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (09) : 1607 - 1610
  • [26] Low Tesla MR Imaging for Spine with Hardware
    Huh, S. N.
    Indelicato, D. J.
    Holtzman, A. L.
    Dagan, R.
    Park, J. Y.
    Brooks, E. D.
    Alghamdi, A.
    Rutenberg, M. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E674 - E674
  • [27] MR Imaging Assessment of the Spine: Infection or an Imitation?
    Hong, Sung Hwan
    Choi, Ja-Young
    Lee, Joon Woo
    Kim, Na Ra
    Choi, Jung-Ah
    Kang, Heung Sik
    RADIOGRAPHICS, 2009, 29 (02) : 599 - U350
  • [28] Extraspinal findings on lumbar spine MR imaging
    Gebara, Nathalie V.
    Meltzer, Daniel E.
    JOURNAL OF RADIOLOGY CASE REPORTS, 2009, 3 (08): : 5 - 13
  • [29] MR imaging of epidural hematoma in the lumbar spine
    Theodore A. Dorsay
    Clyde A. Helms
    Skeletal Radiology, 2002, 31 : 677 - 685
  • [30] MR imaging of cervical spine motion with haste
    Duerinckx, AJ
    Yu, WD
    El-Saden, S
    Kim, D
    Wang, JC
    Sandhu, HS
    MAGNETIC RESONANCE IMAGING, 1999, 17 (03) : 371 - 381