The negative ions adsorption on the ion source surface at the resonant electron capture by molecules and measurements of the ion lifetime

被引:9
|
作者
Lukin, V. G. [1 ]
Khvostenko, O. G. [1 ]
Tuimedov, G. M. [1 ]
机构
[1] Russian Acad Sci, Inst Mol & Crystal Phys, Ufa Res Ctr, Prospect Oktyabrya 151, Ufa, Russia
关键词
Resonance electron capture; Negative ions; Lifetime measurement; Ion adsorption; Hexafluoride; ATTACHMENT; ENERGY; SF6; AUTODETACHMENT; SCATTERING; STATES;
D O I
10.1016/j.ijms.2016.02.005
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Using a static sector magnetic mass spectrometer MI-1201B, modified to record negative ions for resonant electron capture by molecules, the ion extraction time from the ionization chamber combined with this apparatus was measured up to several hundred microseconds. It was shown that the values obtained are anomalously great and they arise from the fact that part of the formed in the ionization chamber ions are adsorbed onto the chamber's surface. Those of them that were produced initially in the gas phase, namely the transient negative ions, with a finite lifetime (similar to 1 mu s and greater), transform themselves, on the surface, into 'infinitely living' (stable) ions. As a result, the contribution of the stable ions to the total ion beam falsifies the ion's lifetime measurements performed with this instrument. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 50 条
  • [21] NEGATIVE-ION SOURCE FOR IMPLANTATION AND SURFACE INTERACTION OF NEGATIVE-ION BEAMS
    ISHIKAWA, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 1290 - 1294
  • [22] Negative Hydrogen Ion Yields at Plasma Grid Surface in a Negative Hydrogen Ion Source
    Wada, M.
    Kenmotsu, T.
    Sasao, M.
    FOURTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2014), 2015, 1655
  • [23] Production and ion-ion cooling of highly charged ions in electron string ion source
    Donets, D. E.
    Donets, E. D.
    Donets, E. E.
    Salnikov, V. V.
    Shutov, V. B.
    Syresin, E. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (06):
  • [24] A hollow cathode ion source for production of primary ions for the BNL electron beam ion source
    Alessi, James
    Beebe, Edward
    Carlson, Charles
    McCafferty, Daniel
    Pikin, Alexander
    Ritter, John
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [25] Negative ion source for chlorine isotope ratio measurements
    Pelc, Andrzej
    Halas, Stanislaw
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (24) : 3977 - 3982
  • [26] ELEMENTARY PROCESSES IN RADIATION CHEMISTRY .2. NEGATIVE ION FORMATION BY ELECTRON CAPTURE IN NEUTRAL MOLECULES
    MAGEE, JL
    BURTON, M
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1951, 73 (02) : 523 - 532
  • [27] Molecular and negative ion production by a standard electron cyclotron resonance ion source
    Racz, R.
    Biri, S.
    Juhasz, Z.
    Sulik, B.
    Palinkas, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [28] Atomic lifetime measurements employing an electron beam ion trap
    Traebert, E.
    CANADIAN JOURNAL OF PHYSICS, 2008, 86 (01) : 73 - 97
  • [29] Ion beam capture and charge breeding in electron cyclotron resonance ion source plasmas
    Kim, Jin-Soo
    Zhao, L.
    Cluggish, B. P.
    Pardo, Richard
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [30] A novel electron source for negative ion mobility spectrometry
    Tabrizchi, M
    Abedi, A
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (01) : 75 - 85