Sensor for hydrogen peroxide based on Prussian Blue modified electrode: Improvement of the operational stability

被引:59
|
作者
de Mattos, IL
Gorton, L
Ruzgas, T
Karyakin, AA
机构
[1] UNESP, Fac Ciencias, Dept Quim, BR-17033360 Bauru, SP, Brazil
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 117234, Russia
关键词
D O I
10.2116/analsci.16.795
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Improvement of the operational stability of amperometric sensors based on Prussian Blue (PB) modified glassy carbon electrodes is presented. The long term performance of the sensors was evaluated by injection of hydrogen peroxide (5 mu M in potassium buffer) solutions in a flow-injection system during a period of 5 - 10 h. The following parameters were investigated and correlated with the performance of the sensor: the times for electrodeposition and electrochemical activation, temperature, storage time, pH, composition of the buffer solution and of volume sample injected. These analytical characteristics of the modified electrode can be emphasized: initial sensitivity of 0.3 A cm(-2) M-1, detection limit of cn. 0.5 mu M, precise results (r.s.d.< 1.5%) and possibility to carry out around 50 samples (50 mu L) per hour.
引用
收藏
页码:795 / 798
页数:4
相关论文
共 50 条
  • [41] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    Suprun, E
    Evtugyn, G
    Budnikov, H
    Ricci, F
    Moscone, D
    Palleschi, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 597 - 604
  • [42] Amperometric thiol sensor based on Prussian blue-modified glassy carbon electrode
    Kafi, A. K. M.
    Yin, Fan
    Shin, Hoon-Kyu
    Kwon, Young-Soo
    CURRENT APPLIED PHYSICS, 2007, 7 (05) : 496 - 499
  • [43] Acetylcholinesterase sensor based on screen-printed carbon electrode modified with prussian blue
    E. Suprun
    G. Evtugyn
    H. Budnikov
    F. Ricci
    D. Moscone
    G. Palleschi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 597 - 604
  • [44] Porous anodic alumina electrode modified with a thin film of Prussian blue: Application to amperometric detection of hydrogen peroxide
    Xu, Guorong
    Ren, Fenglian
    Si, Shihui
    Yi, Qingfeng
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2006, 51 (05): : 234 - 243
  • [45] Development of a Hydrogen Peroxide Sensor Based on Screen-Printed Electrodes Modified with Inkjet-Printed Prussian Blue Nanoparticles
    Cinti, Stefano
    Arduini, Fabiana
    Moscone, Danila
    Palleschi, Giuseppe
    Killard, Anthony J.
    SENSORS, 2014, 14 (08): : 14222 - 14234
  • [46] Enzymeless voltammetric hydrogen peroxide sensor based on the use of PEDOT doped with Prussian Blue nanoparticles
    Wang, Junjie
    Wang, Yu
    Cui, Min
    Xu, Shenghao
    Luo, Xiliang
    MICROCHIMICA ACTA, 2017, 184 (02) : 483 - 489
  • [47] Enzymeless voltammetric hydrogen peroxide sensor based on the use of PEDOT doped with Prussian Blue nanoparticles
    Junjie Wang
    Yu Wang
    Min Cui
    Shenghao Xu
    Xiliang Luo
    Microchimica Acta, 2017, 184 : 483 - 489
  • [48] Electrosynthesis of poly-o-diaminobenzene on the Prussian Blue modified electrodes for improvement of hydrogen peroxide transducer characteristics
    Lukachova, LV
    Kotel'nikova, EA
    D'Ottavi, D
    Shkerin, EA
    Karyakina, EE
    Moscone, D
    Palleschi, G
    Curulli, A
    Karyakin, AA
    BIOELECTROCHEMISTRY, 2002, 55 (1-2) : 145 - 148
  • [49] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrodes: a RDE study
    R. Araminaitė
    R. Garjonytė
    A. Malinauskas
    Journal of Solid State Electrochemistry, 2010, 14 : 149 - 155
  • [50] Electrocatalytic reduction of hydrogen peroxide at Prussian blue modified electrodes: a RDE study
    Araminaite, R.
    Garjonyte, R.
    Malinauskas, A.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (01) : 149 - 155