The Effect of Crown-to-Implant Ratio on the Clinical Performance of Extra-Short Locking-Taper Implants

被引:27
|
作者
Mangano, Francesco [1 ]
Frezzato, Irene
Frezzato, Alberto
Veronesi, Giovanni [2 ]
Mortellaro, Carmen [3 ]
Mangano, Carlo [4 ]
机构
[1] Univ Varese, Dept Surg & Morphol Sci, Varese, Italy
[2] Univ Varese, Dept Clin & Expt Med, Varese, Italy
[3] Univ Piemonte Orientale, Dept Hlth Sci, Novara, Italy
[4] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Chieti, Italy
关键词
Complications; dental implants; extra-short implants; peri-implant marginal bone loss; survival; SUPPORTING SINGLE CROWNS; SHORT DENTAL IMPLANTS; RANDOMIZED CONTROLLED-TRIAL; CRESTAL BONE LOSS; FOLLOW-UP; POSTERIOR REGION; CONNECTION IMPLANTS; AESTHETIC EVALUATION; PROSTHETIC TREATMENT; CROWN/IMPLANT RATIO;
D O I
10.1097/SCS.0000000000002562
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of the present prospective 5-year study was to evaluate the influence of crown-to-implant ratio (C/I ratio) on the survival, peri-implant marginal bone loss, and complications of extra-short (6.5 mm) locking-taper implants placed in the posterior areas of the jaw. Methods: Over a 2-year period, all patients presenting with partial edentulism associated with vertical defects of the posterior alveolar ridges and sufficient bone volume to place extra-short (6.5mm length x 5mm diameter) implants were considered for inclusion in this study. Results: Fifty-one patients (22 men, 29 women; aged between 40 and 75 years) were included in this study. Sixty-eight extra-short, locking-taper implants were placed to support 49 single crowns and 9 fixed partial dentures. The C/I ratio was <2 for 51 implants and >= 2 for 17 implants. All patients underwent the 5-year clinical examination. Two implants failed. Failure proportion was 2% in the C/I<2 group, and 6% in the C/I >= 2 group: this difference was not statistically significant (P = 0.4). After 1 year of loading, a mean marginal bone loss of 0.29 and 0.39 was reported in the C/I<2 group and the C/I >= 2 group, respectively. After 5 years of loading, a mean marginal bone loss of 0.38 and 0.48 was reported in the C/I<2 and C/I >= 2 groups, respectively. The linear regression model failed to find a correlation between the C/I ratio and marginal bone loss along time, with a 0.023mm (95% CI: -0.002; 0.048) increase in 1-year bone resorption for every 0.1 increase in C/I ratio (P = 0.07). At 5-year, the association reduced to 0.019mm (P = 0.18). Only a few complications were reported. There was no statistically significant difference in the prevalence of biological (P = 0.9) complications between the 2 groups. Prosthetic complications were more frequent with C/I>2 (12.5%) than with C/I<2 (6%), but this difference was not statistically significant (P = 0.6). Conclusions: Extra-short, locking-taper implants may be successfully used in the posterior areas of the jaw.
引用
收藏
页码:675 / 681
页数:7
相关论文
共 50 条
  • [31] The influence of crown-to-implant ratio in single crowns on clinical outcomes: A systematic review and meta-analysis
    Pellizzer, Eduardo Piza
    Gomes, Jessica Marcela de Luna
    Lemos, Cleidiel Aparecido Araujo
    Minatel, Lurian
    Limirio, Joao Pedro Justino de Oliveira
    de Moraes, Sandra Lucia Dantas
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (04): : 497 - 502
  • [32] Factors Associated with Crestal Bone Gain on Single-Tooth Locking-Taper Implants: The Effect of Nonsteroidal Anti-Inflammatory Drugs
    Urdaneta, Rainier A.
    Daher, Shadi
    Leary, Joseph
    Emanuel, Kimberly
    Chuang, Sung-Kiang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (05) : 1063 - 1078
  • [33] Relationship Between Crestal Bone Levels and Crown-to-Implant Ratio of Ultra-Short Implants with a Microrough Surface: A Prospective Study With 48 Months of Follow-Up
    Malchiodi, Luciano
    Giacomazzi, Erika
    Cucchi, Alessandro
    Ricciotti, Giulia
    Caricasulo, Riccardo
    Bertossi, Dario
    Gherlone, Enrico
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (01) : 18 - 28
  • [34] Comparative Analysis of Peri-Implant Bone Loss in Extra-Short, Short, and Conventional Implants. A 3-Year Retrospective Study
    Estevez-Perez, Dayceli
    Bustamante-Hernandez, Naia
    Labaig-Rueda, Carlos
    Fernanda Sola-Ruiz, Maria
    Amengual-Lorenzo, Jose
    Bonmati, Fernando Garcia-Sala
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (24) : 1 - 14
  • [35] Change in Crown-to-Implant Ratio of Implants Placed in Grafted and Nongrafted Posterior Maxillary Sites: A 5-year Prospective Randomized Study
    Nedir, Rabah
    Nurdin, Nathalie
    Huynh-Ba, Guy
    Bischof, Mark
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1227 - 1232
  • [36] Prospective, Clinical Pilot Study with Eleven 4-Mm Extra-Short Implants Splinted to Longer Implants for Posterior Maxilla Rehabilitation
    Torassa, Daniel
    Naldini, Pablo
    Luis Calvo-Guirado, Jose
    Fernandez-Bodereau, Enrique
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [37] Short (8-mm) locking-taper implants supporting single crowns in posterior region: a prospective clinical study with 1-to 10-years of follow-up
    Mangano, Francesco Guido
    Shibli, Jamil Awad
    Sammons, Rachel Lilian
    Iaculli, Flavia
    Piattelli, Adriano
    Mangano, Carlo
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 933 - 940
  • [38] Clinical and radiographic outcomes of extra-short implants (≤ 6 mm) in the posterior atrophic jaws: a retrospective cohort study
    Sivolella, Stefano
    Giovannini, Stefano
    Berberi, Joana
    Stocchero, Michele
    Brunello, Giulia
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [39] Clinical Outcome of Narrow-Diameter (3.3-mm) Locking-Taper Implants: A Prospective Study with 1 to 10 Years of Follow-up
    Mangano, Francesco
    Shibli, Jamil A.
    Sammons, Rachel L.
    Veronesi, Giovanni
    Piattelli, Adriano
    Mangano, Carlo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 448 - 455
  • [40] Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test
    Verri, Fellippo Ramos
    Santiago Junior, Joel Ferreira
    de Faria Almeida, Daniel Augusto
    Brandao de Oliveira, Guilherme Bergamo
    de Souza Batista, Victor Eduardo
    Honorio, Heitor Marques
    Noritomi, Pedro Yoshito
    Pellizzer, Eduardo Piza
    JOURNAL OF BIOMECHANICS, 2015, 48 (01) : 138 - 145