Photon-counting MCP/Timepix detectors for soft X-ray imaging and spectroscopic applications

被引:6
|
作者
Tremsin, Anton S. [1 ]
Vallerga, John V. [1 ]
Siegmund, Oswald H. W. [1 ]
Woods, Justin [2 ]
De Long, Lance E. [3 ]
Hastings, Jeffrey T. [3 ]
Koch, Roland J. [4 ]
Morley, Sophie A. [4 ]
Chuang, Yi-De [4 ]
Roy, Sujoy [4 ]
机构
[1] Univ Kentucky, Space Sci Lab, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Phys & Astron, Lexington, KY 40506 USA
[3] Univ Kentucky, Dept Elect & Comp Engn, Lexington, KY 40506 USA
[4] Lawrence Berkeley Natl Lab, Adv Light Source, 1 Cyclotron Rd, Berkeley, CA 94720 USA
基金
美国国家航空航天局; 美国国家科学基金会;
关键词
soft X-ray detectors; photon counting; microchannel plates; X-ray photon correlation spectroscopy; Timepix; PIXEL READOUT CHIP; CENTROIDING ALGORITHMS; DETECTION SYSTEM; RESOLUTION; TIME; OPTIMIZATION; DYNAMICS;
D O I
10.1107/S1600577521003908
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Detectors with microchannel plates (MCPs) provide unique capabilities to detect single photons with high spatial (<10 mu m) and timing (<25 ps) resolution. Although this detection technology was originally developed for applications with low event rates, recent progress in readout electronics has enabled their operation at substantially higher rates by simultaneous detection of multiple particles. In this study, the potential use of MCP detectors with Timepix readout for soft X-ray imaging and spectroscopic applications where the position and time of each photon needs to be recorded is investigated. The proof-of-principle experiments conducted at the Advanced Light Source demonstrate the capabilities of MCP/Timepix detectors to operate at relatively high input counting rates, paving the way for the application of these detectors in resonance inelastic X-ray scattering and X-ray photon correlation spectroscopy (XPCS) applications. Local count rate saturation was investigated for the MCP/ Timepix detector, which requires optimization of acquisition parameters for a specific scattering pattern. A single photon cluster analysis algorithm was developed to eliminate the charge spreading effects in the detector and increase the spatial resolution to subpixel values. Results of these experiments will guide the ongoing development of future MCP devices optimized for soft X-ray photon-counting applications, which should enable XPCS dynamics measurements down to sub-microsecond timescales.
引用
收藏
页码:1069 / 1080
页数:12
相关论文
共 50 条
  • [21] Spectral computed tomography in the age of photon-counting X-ray detectors
    Rotkopf, Lukas T.
    Wehrse, Eckhard
    Froelich, Matthias F.
    RADIOLOGIE, 2022, 62 (06): : 504 - 510
  • [22] Guidelines for the Selection of Scintillators for Indirect Photon-Counting X-ray Detectors
    van Blaaderen, J. Jasper
    van Aarle, Casper
    Leibold, David
    Dorenbos, Pieter
    Schaart, Dennis R.
    CHEMISTRY OF MATERIALS, 2025, 37 (05) : 1716 - 1740
  • [23] Simultaneous X-ray fluorescence and K-edge CT imaging with photon-counting detectors
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Chen, Zhiqiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [24] Single-shot x-ray phase imaging with grating interferometry and photon-counting detectors
    Wang, Zhili
    Gao, Kun
    Wang, Dajiang
    Wu, Zhao
    Chen, Heng
    Wang, Shenghao
    Wu, Ziyu
    OPTICS LETTERS, 2014, 39 (04) : 877 - 879
  • [25] Photon-counting CCD detector as a tool of x-ray imaging
    Liang, Y
    Ida, K
    Kado, S
    Minami, T
    Okamura, S
    Nomura, I
    Watanabe, KY
    Yamada, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 717 - 720
  • [26] Photon-counting X-ray imaging at kilohertz frame rates
    Ponchut, Cyril
    Clement, Joel
    Rigal, Jean-Marie
    Papillon, Emmanuel
    Vallerga, John
    LaMarra, Daniel
    Mikulec, Bettina
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 109 - 112
  • [27] Characterization of a Pixelated CdTe X-Ray Detector Using the Timepix Photon-Counting Readout Chip
    Ruat, Marie
    Ponchut, Cyril
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2392 - 2401
  • [28] PHOTON-COUNTING SPECTROMETER FOR ATTENUATION MEASUREMENTS IN SOFT X-RAY REGION
    BEDO, DE
    TOMBOULIAN, DH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (02): : 184 - &
  • [29] X-ray photon counting detectors for preclinical and clinical applications
    REN Liqiang
    LIU Hong
    Instrumentation, 2016, 3 (04) : 43 - 54
  • [30] Novel, photon counting detectors for x-ray diffraction applications
    Diawara, Y
    Khazins, D
    Medved, S
    Becker, B
    Durst, RD
    Thorson, T
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 358 - 364