Magnetic Resonance Imaging of the Codman Microsensor Transducer Used for Intraspinal Pressure Monitoring

被引:10
|
作者
Phang, Isaac [1 ]
Mada, Marius [2 ]
Kolias, Angelos G. [3 ]
Newcombe, Virginia F. J. [2 ]
Trivedi, Rikin A. [3 ]
Carpenter, Adrian [2 ]
Hawkes, Rob C. [2 ]
Papadopoulos, Marios C. [1 ]
机构
[1] St Georges Univ London, Acad Neurosurg Unit, London SW17 0RE, England
[2] Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge, England
[3] Addenbrookes Hosp, Div Neurosurg, Dept Clin Neurosci, Cambridge, England
关键词
heating; human; ISP; magnetic; MRI; paralysis; radiofrequency; safety; spinal cord injury; spinal cord perfusion pressure; transducer; CORD PERFUSION-PRESSURE; INJURY;
D O I
10.1097/BRS.0000000000001334
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Laboratory and human study. Objective. To test the Codman Microsensor Transducer (CMT) in a cervical gel phantom. To test the CMT inserted to monitor intraspinal pressure in a patient with spinal cord injury. Summary of Background Data. We recently introduced the technique of intraspinal pressure monitoring using the CMT to guide management of traumatic spinal cord injury [Werndle et al. Crit Care Med 2014; 42: 646]. This is analogous to intracranial pressure monitoring to guide management of patients with traumatic brain injury. It is unclear whether magnetic resonance imaging (MRI) of patients with spinal cord injury is safe with the intraspinal pressure CMT in situ. Methods. We measured the heating produced by the CMT placed in a gel phantom in various configurations. A 3-T MRI system was used with the body transmit coil and the spine array receive coil. A CMT was then inserted subdurally at the injury site in a patient who had traumatic spinal cord injury and MRI was performed at 1.5 T. Results. In the gel phantom, heating of up to 5 degrees C occurred with the transducer wire placed straight through the magnet bore. The heating was abolished when the CMT wire was coiled and passed away from the bore. We then tested the CMT in a patient with an American Spinal Injuries Association grade C cervical cord injury. The CMT wire was placed in the configuration that abolished heating in the gel phantom. Good-quality T1 and T2 images of the cord were obtained without neurological deterioration. The transducer remained functional after the MRI. Conclusion. Our data suggest that the CMT is MR conditional when used in the spinal configuration in humans. Data from a large patient group are required to confirm these findings.
引用
收藏
页码:E605 / E610
页数:6
相关论文
共 50 条
  • [31] Direct access magnetic resonance imaging of the knee for GPs - Magnetic resonance imaging should be used selectively
    Southgate, J
    Thomas, N
    BRITISH MEDICAL JOURNAL, 1996, 312 (7034): : 849 - 849
  • [33] Transcutaneous pressure-adjustable valves and magnetic resonance imaging: An ex vivo examination of the Codman-Medos programmable valve and the Sophy adjustable pressure valve - Comments
    McLone, DG
    McComb, JG
    Sindou, M
    Drake, JM
    NEUROSURGERY, 1997, 40 (05) : 1057 - 1058
  • [34] Intraspinal anomalies associated with isolated congenital hemivertebra: The role of routine magnetic resonance imaging
    Belmont, PJ
    Kuklo, TR
    Taylor, KF
    Freedman, BA
    Prahinski, JR
    Kruse, RW
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1704 - 1710
  • [35] When should abdominal magnetic resonance imaging be used?
    Goncalves Neto, Jose A.
    Elazzazzi, Mohamed
    Altun, Ersan
    Semelka, Richard C.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (06) : 610 - 615
  • [36] Magnetic Resonance Imaging of Normal Pressure Hydrocephalus
    Bradley, William G., Jr.
    SEMINARS IN ULTRASOUND CT AND MRI, 2016, 37 (02) : 120 - 128
  • [37] CONTINUOUS ARTERIAL-PRESSURE MONITORING DURING MAGNETIC-RESONANCE-IMAGING - AN ALTERNATIVE METHOD
    EMMONS, SW
    MARTIN, HB
    ANESTHESIA AND ANALGESIA, 1992, 74 (02): : 315 - 316
  • [38] Aetiology of herniation of the hindbrain in craniosynostosis - An investigation incorporating intracranial pressure monitoring and magnetic resonance imaging
    Thompson, DNP
    Harkness, W
    Jones, BM
    Hayward, RD
    PEDIATRIC NEUROSURGERY, 1997, 26 (06) : 288 - 295
  • [39] SUPRASPINAL CONTROL OF DEFECATION USING CONCURRENT FUNCTIONAL MAGNETIC RESONANCE IMAGING AND RECTAL PRESSURE MONITORING
    Neshatian, Leila
    Quigley, Eamonn
    Khavari, Rose
    Elias, Saba
    Karmonik, Christof
    GASTROENTEROLOGY, 2017, 152 (05) : S929 - S929
  • [40] Overheated and melted intracranial pressure transducer as cause of thermal brain injury during magnetic resonance imaging Case report
    Tanaka, Reiichiro
    Yumoto, Tetsuya
    Shiba, Naoki
    Okawa, Motohisa
    Yasuhara, Takao
    Ichikawa, Tomotsugu
    Tokunaga, Koji
    Date, Isao
    Ujike, Yoshihito
    JOURNAL OF NEUROSURGERY, 2012, 117 (06) : 1100 - 1109