Magnetic Resonance Imaging of the Codman Microsensor Transducer Used for Intraspinal Pressure Monitoring

被引:10
|
作者
Phang, Isaac [1 ]
Mada, Marius [2 ]
Kolias, Angelos G. [3 ]
Newcombe, Virginia F. J. [2 ]
Trivedi, Rikin A. [3 ]
Carpenter, Adrian [2 ]
Hawkes, Rob C. [2 ]
Papadopoulos, Marios C. [1 ]
机构
[1] St Georges Univ London, Acad Neurosurg Unit, London SW17 0RE, England
[2] Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge, England
[3] Addenbrookes Hosp, Div Neurosurg, Dept Clin Neurosci, Cambridge, England
关键词
heating; human; ISP; magnetic; MRI; paralysis; radiofrequency; safety; spinal cord injury; spinal cord perfusion pressure; transducer; CORD PERFUSION-PRESSURE; INJURY;
D O I
10.1097/BRS.0000000000001334
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Laboratory and human study. Objective. To test the Codman Microsensor Transducer (CMT) in a cervical gel phantom. To test the CMT inserted to monitor intraspinal pressure in a patient with spinal cord injury. Summary of Background Data. We recently introduced the technique of intraspinal pressure monitoring using the CMT to guide management of traumatic spinal cord injury [Werndle et al. Crit Care Med 2014; 42: 646]. This is analogous to intracranial pressure monitoring to guide management of patients with traumatic brain injury. It is unclear whether magnetic resonance imaging (MRI) of patients with spinal cord injury is safe with the intraspinal pressure CMT in situ. Methods. We measured the heating produced by the CMT placed in a gel phantom in various configurations. A 3-T MRI system was used with the body transmit coil and the spine array receive coil. A CMT was then inserted subdurally at the injury site in a patient who had traumatic spinal cord injury and MRI was performed at 1.5 T. Results. In the gel phantom, heating of up to 5 degrees C occurred with the transducer wire placed straight through the magnet bore. The heating was abolished when the CMT wire was coiled and passed away from the bore. We then tested the CMT in a patient with an American Spinal Injuries Association grade C cervical cord injury. The CMT wire was placed in the configuration that abolished heating in the gel phantom. Good-quality T1 and T2 images of the cord were obtained without neurological deterioration. The transducer remained functional after the MRI. Conclusion. Our data suggest that the CMT is MR conditional when used in the spinal configuration in humans. Data from a large patient group are required to confirm these findings.
引用
收藏
页码:E605 / E610
页数:6
相关论文
共 50 条
  • [1] Intracranial Pressure Monitoring Using the Codman MicroSensor
    Koskinen, Lars-Owe D.
    Olivecrona, Magnus
    NEUROSURGERY, 2010, 67 (01) : E221 - E221
  • [2] A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring
    Signorini, DF
    Shad, A
    Piper, IR
    Statham, PFX
    BRITISH JOURNAL OF NEUROSURGERY, 1998, 12 (03) : 223 - 227
  • [3] Clinical evaluation of the Codman microsensor intracranial pressure monitoring system
    Fernandes, HM
    Bingham, K
    Chambers, IR
    Mendelow, AD
    INTRACRANIAL PRESSURE AND NEUROMONITORING IN BRAIN INJURY, 1998, 71 : 44 - 46
  • [4] Potential heating caused by intraparenchymal intracranial pressure transducers in a 3-tesla magnetic resonance imaging system using a body radiofrequency resonator: assessment of the Codman MicroSensor Transducer
    Newcombe, Virginia F. J.
    Hawkes, Robert C.
    Harding, Sally G.
    Willcox, Roslyn
    Brock, Sarah
    Hutchinson, Peter J.
    Menon, David K.
    Carpenter, T. Adrian
    Coles, Jonathan P.
    JOURNAL OF NEUROSURGERY, 2008, 109 (01) : 159 - 164
  • [5] Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system
    Koskinen, LOD
    Olivecrona, M
    NEUROSURGERY, 2005, 56 (04) : 693 - 697
  • [6] Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system - Comments
    Liu, CY
    Grossman, RG
    Bullock, MR
    NEUROSURGERY, 2005, 56 (04) : 697 - 698
  • [7] Left atrial pressure monitoring in patients with a HeartMate II device using a Codman Microsensor
    Gosev, Igor
    Marzia, Leacche
    Neely, Robert C.
    Couper, Gregory S.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04): : 1425 - 1427
  • [8] Subdural intracranial pressure monitoring in severe head injury: clinical experience with the Codman MicroSensor
    Hong, Wei-Chen
    Tu, Yong-Kwang
    Chen, Yuan-Shen
    Lien, Li-Ming
    Huang, Sheng-Jean
    SURGICAL NEUROLOGY, 2006, 66 : S8 - S13
  • [9] Magnetic resonance imaging of intraspinal melanotic schwannoma
    Bendszus, M
    Urbach, H
    Wolf, HK
    Schramm, J
    Solymosi, L
    EUROPEAN RADIOLOGY, 1998, 8 (07) : 1197 - 1197
  • [10] Magnetic resonance imaging of intraspinal melanotic schwannoma
    M. Bendszus
    H. Urbach
    H. K. Wolf
    J. Schramm
    L. Solymosi
    European Radiology, 1998, 8 : 1197 - 1197