Highly dispersive AuNCs/ChOx@ZIF-8/PEI nanocomplexes for fluorescent detection of cholesterol in human serum

被引:7
|
作者
Ding, Jinglei [1 ]
Zhang, Wenqi [1 ]
Xue, Fengying [1 ]
Sun, Yu [1 ]
Yan, Quizhu [1 ]
Chen, Yanwei [1 ]
Shan, Guiye [1 ]
机构
[1] Northeast Normal Univ, Ctr Adv Optoelect Funct Mat Res, Key Lab UV Light Emitting Mat & Technol, Minist Educ, Changchun 130024, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoclusters; Metal-organic framework ZIF-8; Fluorescent detection; Cholesterol; METAL-ORGANIC FRAMEWORKS; GOLD NANOCLUSTERS; AU NANOCLUSTERS; CO2; ADSORPTION; NANOPARTICLES; BIOSENSOR; SENSOR; AUNCS; ZIF-8; EMISSION;
D O I
10.1007/s00604-022-05306-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoclusters (AuNCs) are widely used in the fluorescence detection of biomolecules in human serum due to their good fluorescence properties, low toxicity, and better biocompatibility. However, the weak fluorescence intensity of AuNCs limits the fluorescence detection of molecules within a wide concentration range. It is reported that coating AuNCs in ZIF-8 with adjustable pore size can effectively improve the fluorescence intensity of AuNCs and broaden the detection range. And the AuNCs wrapped in the gaps of ZIF-8 can prevent the fluorescence quenching caused by the aggregation of AuNCs. However, ZIF-8 has high crystallinity, poor dispersion, and easy deposition, which reduces the fluorescence stability of the detection system and affects the detection. Based on the above research, the highly hydrophilic polymer PEI was modified to the surface of ZIF-8, and a kind of nanocomposite material AuNCs/ChOx@ZIF-8/PEI was obtained by co-encapsulating AuNCs prepared with glutathione as a ligand and cholesterol oxidase (ChOx) into ZIF-8 modified with PEI. The composite material emits strong red light at 650 nm under the excitation of 395-nm light, and the system can sensitively detect cholesterol (Chol) in human serum. Compared with other materials, the PEI-modified composite has better solubility and stability, so the detection effect of Chol is better. Encapsulation of ChOx in the ZIF-8 shell can protect the enzyme and increase the local concentration of ChOx, thereby speeding up the reaction rate. Compared with free AuNCs/ChOx, the quenching rate of AuNCs/ChOx@ZIF-8/PEI system is doubled. Secondly, the addition of Fe2+ to the detection process results in higher quenching rate and detection sensitivity. The system can detect Chol in the concentration range 0.1-2.4 mu M, with a detection limit of 0.073 mu M. The determination is a fast and sensitive strategy. In addition, the practicability of this assay in the detection of Chol in human serum has been verified. Due to its selectivity and sensitivity, it has potential application value in clinical diagnosis.
引用
收藏
页数:10
相关论文
共 27 条
  • [21] A highly sensitive and selective "turn-on" fluorescent probe for detection of fleroxacin in human serum and urine based on a lanthanide functionalized metal-organic framework
    Liu, Tian-Yu
    Qu, Xiang-Long
    Yan, Bing
    DALTON TRANSACTIONS, 2019, 48 (48) : 17945 - 17952
  • [22] Nitrogen and Phosphorus Co-Doped Carbon Nanodots as a Novel Fluorescent Probe for Highly Sensitive Detection of Fe3+ in Human Serum and Living Cells
    Shi, Bingfang
    Su, Yubin
    Zhang, Liangliang
    Huang, Mengjiao
    Liu, Rongjun
    Zhao, Shulin
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (17) : 10717 - 10725
  • [23] Highly sensitive light-up near-infrared fluorescent probe for detection and imaging of β-glucuronidase in human serum, living cells and tumor-bearing mice
    Zhou, Xin
    Wang, Deping
    Gao, Zhiyuan
    He, Mingyue
    Hou, Jiayi
    Zhang, Hui
    Zhang, Guoqiang
    Ding, Dan
    Feng, Guangxue
    SCIENCE CHINA-MATERIALS, 2022, 65 (03) : 836 - 844
  • [24] Detection of IL-8 in human serum using surface-enhanced Raman scattering coupled with highly-branched gold nanoparticles and gold nanocages
    Wang, Zhen-yu
    Li, Wei
    Gong, Zheng
    Sun, Pei-rong
    Zhou, Tong
    Cao, Xiao-wei
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1733 - 1742
  • [25] A highly selective electrochemical immunosensor based on conductive carbon black and star PGMA polymer composite material for IL-8 biomarker detection in human serum and saliva
    Aydin, Muhammet
    Aydin, Elif Burcu
    Sezginturk, Mustafa Kemal
    BIOSENSORS & BIOELECTRONICS, 2018, 117 : 720 - 728
  • [26] An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications
    Aydin, Elif Burcu
    Sezginturk, Mustafa Kemal
    ANALYTICAL BIOCHEMISTRY, 2018, 554 : 44 - 52
  • [27] Highly sensitive light-up near-infrared fluorescent probe for detection and imaging of β-glucuronidase in human serum, living cells and tumor-bearing mice用于血清、活细胞及小鼠荷瘤中β-葡萄糖醛酸苷酶检测成像的高灵敏点亮型近红外荧光探针
    Xin Zhou
    Deping Wang
    Zhiyuan Gao
    Mingyue He
    Jiayi Hou
    Hui Zhang
    Guoqiang Zhang
    Dan Ding
    Guangxue Feng
    Science China Materials, 2022, 65 : 836 - 844