Highly dispersive AuNCs/ChOx@ZIF-8/PEI nanocomplexes for fluorescent detection of cholesterol in human serum

被引:7
|
作者
Ding, Jinglei [1 ]
Zhang, Wenqi [1 ]
Xue, Fengying [1 ]
Sun, Yu [1 ]
Yan, Quizhu [1 ]
Chen, Yanwei [1 ]
Shan, Guiye [1 ]
机构
[1] Northeast Normal Univ, Ctr Adv Optoelect Funct Mat Res, Key Lab UV Light Emitting Mat & Technol, Minist Educ, Changchun 130024, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoclusters; Metal-organic framework ZIF-8; Fluorescent detection; Cholesterol; METAL-ORGANIC FRAMEWORKS; GOLD NANOCLUSTERS; AU NANOCLUSTERS; CO2; ADSORPTION; NANOPARTICLES; BIOSENSOR; SENSOR; AUNCS; ZIF-8; EMISSION;
D O I
10.1007/s00604-022-05306-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold nanoclusters (AuNCs) are widely used in the fluorescence detection of biomolecules in human serum due to their good fluorescence properties, low toxicity, and better biocompatibility. However, the weak fluorescence intensity of AuNCs limits the fluorescence detection of molecules within a wide concentration range. It is reported that coating AuNCs in ZIF-8 with adjustable pore size can effectively improve the fluorescence intensity of AuNCs and broaden the detection range. And the AuNCs wrapped in the gaps of ZIF-8 can prevent the fluorescence quenching caused by the aggregation of AuNCs. However, ZIF-8 has high crystallinity, poor dispersion, and easy deposition, which reduces the fluorescence stability of the detection system and affects the detection. Based on the above research, the highly hydrophilic polymer PEI was modified to the surface of ZIF-8, and a kind of nanocomposite material AuNCs/ChOx@ZIF-8/PEI was obtained by co-encapsulating AuNCs prepared with glutathione as a ligand and cholesterol oxidase (ChOx) into ZIF-8 modified with PEI. The composite material emits strong red light at 650 nm under the excitation of 395-nm light, and the system can sensitively detect cholesterol (Chol) in human serum. Compared with other materials, the PEI-modified composite has better solubility and stability, so the detection effect of Chol is better. Encapsulation of ChOx in the ZIF-8 shell can protect the enzyme and increase the local concentration of ChOx, thereby speeding up the reaction rate. Compared with free AuNCs/ChOx, the quenching rate of AuNCs/ChOx@ZIF-8/PEI system is doubled. Secondly, the addition of Fe2+ to the detection process results in higher quenching rate and detection sensitivity. The system can detect Chol in the concentration range 0.1-2.4 mu M, with a detection limit of 0.073 mu M. The determination is a fast and sensitive strategy. In addition, the practicability of this assay in the detection of Chol in human serum has been verified. Due to its selectivity and sensitivity, it has potential application value in clinical diagnosis.
引用
收藏
页数:10
相关论文
共 27 条
  • [1] Highly dispersive AuNCs/ChOx@ZIF-8/PEI nanocomplexes for fluorescent detection of cholesterol in human serum
    Jinglei Ding
    Wenqi Zhang
    Fengying Xue
    Yu Sun
    Quizhu Yan
    Yanwei Chen
    Guiye Shan
    Microchimica Acta, 2022, 189
  • [2] A highly sensitive fluorescence "on-off-on" sensing platform for captopril detection based on AuNCs@ZIF-8 nanocomposite
    Guo, Yongyan
    Zhang, Jiabao
    Liu, Jinying
    Wang, Nan
    Su, Xingguang
    ANALYTICA CHIMICA ACTA, 2023, 1276
  • [3] Pd Nanoclusters Confined in ZIF-8 Matrixes for Fluorescent Detection of Glucose and Cholesterol
    Li, Ying
    Li, Shujuan
    Bao, Min
    Zhang, Linqun
    Carraro, Carlo
    Maboudian, Roya
    Liu, Anran
    Wei, Wei
    Zhang, Yuanjian
    Liu, Songqin
    ACS APPLIED NANO MATERIALS, 2021, 4 (09) : 9132 - 9142
  • [4] A ratiometric fluorescent nanoprobe based on ZIF-8@AuNCs-Tb for visual detection of 2,6-pyridinedicarboxylic acid
    Kang Shao
    Siyu Wen
    Mengyuan Zhang
    Jing Wang
    Shiyi Ye
    Zaifa Pan
    JournalofRareEarths, 2022, 40 (08) : 1165 - 1172
  • [5] A ratiometric fluorescent nanoprobe based on ZIF-8@AuNCs-Tb for visual detection of 2,6-pyridinedicarboxylic acid
    Shao, Kang
    Wen, Siyu
    Zhang, Mengyuan
    Wang, Jing
    Ye, Shiyi
    Pan, Zaifa
    JOURNAL OF RARE EARTHS, 2022, 40 (08) : 1165 - 1172
  • [6] Highly dispersive PEI-modified CDs@ZIF-L dual-emitting fluorescent sensor for detecting metal ions
    Liu, Xiaoyun
    Sun, Chunyan
    Chai, Mingxia
    Song, Weijun
    RSC ADVANCES, 2023, 13 (45) : 31353 - 31364
  • [7] Construction of a N-CDs/AuNCs@ZIF-8-assisted ratiometric fluorescent nanosensor for glyphosate detection in edible and medicinal malt
    Lei, Doudou
    Li, Lingling
    Song, Pengyue
    Xu, QingBin
    Huang, Lihua
    Ma, Xiao
    Zhou, Lidong
    Kong, Weijun
    FOOD CHEMISTRY-X, 2024, 24
  • [8] Highly Fluorescent Magnetic ATT-AuNCs@ZIF-8 for All-in-One Detection and Removal of Hg2+: An Ultrasensitive Probe to Evaluate Its Removal Efficiency
    Bi, Xiaoya
    Li, Libo
    Niu, Qijian
    Liu, Xiaohong
    Luo, Lijun
    Jiang, Huihui
    You, Tianyan
    INORGANIC CHEMISTRY, 2023, 62 (07) : 3123 - 3133
  • [9] Smartphone-assisted fluorescence sensor based on AuNCs/ZIF-8 for highly selective detection of Sb3+ ions
    Liu, Rong
    Wang, Zhiya
    Hu, Xinyao
    Tang, Haitao
    Deng, Ningjie
    Liu, Shiquan
    Wu, Zhaoyang
    MICROCHIMICA ACTA, 2025, 192 (03)
  • [10] Molecular engineering of a fluorescent probe for highly efficient detection of human serum albumin in biological fluid
    Chinnappan, Raja (rchinnappan@alfaisal.edu); Mir, Tanveer Ahmad (tmir@kfshrc.edu.sa), 2025, 6